Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0018-A-03-B-ET-EC-EM-NN-NN-FW belongs to the HCS IndraDrive Controllers series and is designed as a drive controller with an internal air cooling method that uses an integrated blower. This model features MultiEthernet communication, supports encoder interfaces including IndraDyn Hiperface and EnDat 2.1/2.2, and operates at a device peak current of 18 Amps with an IP20 protection rating.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0018-A-03-B-ET-EC-EM-NN-NN-FW drive controller is manufactured by Bosch Rexroth Indramat and belongs to the HCS IndraDrive Controllers series. It acts as the regulated link between a plant’s three-phase mains and servo or spindle motors, shaping voltage and current so axes follow commanded speed, torque, or position profiles. Within automated assembly cells, packaging lines, and material-handling stations, this controller integrates into motion networks to coordinate rapid, repeatable moves while protecting connected motors from overload and supply disturbances.

Its electrical front end accepts three-phase supplies rated at 3 × AC 200…500 V ±10%, allowing the same hardware to be used on a wide range of factory voltages. From that range, it delivers a device peak current of 18 A, giving short-term torque surges when axes accelerate. The IP20 housing provides protection against finger contact and vertical dripping water, making it suitable for installation inside switchgear cabinets. Network traffic for setup, diagnostics, and real-time setpoints is handled by the MultiEthernet communication interface, which supports several Ethernet-based fieldbuses without extra option cards. The unit is Design Version 1.

The control section installed on the power base is the BASIC variant, providing standard motion functions without integrated safety channels. Feedback signals from motors are accepted on the first port through IndraDyn Hiperface / EnDat 2.1/2.2, while a second port outputs an encoder emulation signal for legacy drives or external position controllers. Thermal management relies on internal air cooling through an integrated blower, eliminating the need for cabinet ducting. No dedicated safe-torque-off terminals are present, and energy exchange with the DC bus is handled by an infeeding module so regenerated power can be shared across coordinated axes.

Communication Interface
MultiEthernet
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
18 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Encoder emulation
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Safety Interface
Not equipped
  • HCS011EW0018A03BETECEMNNNNFW
  • HCS01 1E W0018 A 03 B ET EC EM NN NN FW
  • hcs01.1e-w0018-a-02-e-s3-ec-nn-l4-nn-fw
  • HCS1.1E-W0018-A-03-B-ET-EC-EM-NN-NN-FW

Frequently Asked Questions about HCS01.1E-W0018-A-03-B-ET-EC-EM-NN-NN-FW:

Q: What communication interface is available on the HCS01.1E-W0018-A-03-B-ET-EC-EM-NN-NN-FW?

A: This drive controller supports MultiEthernet for versatile communication compatibility.

Q: How is the HCS01.1E-W0018-A-03-B-ET-EC-EM-NN-NN-FW drive controller cooled?

A: The HCS01.1E-W0018-A-03-B-ET-EC-EM-NN-NN-FW is cooled internally using an integrated blower.

Q: What is the device peak current rating of the HCS01.1E-W0018-A-03-B-ET-EC-EM-NN-NN-FW controller?

A: This model can deliver a peak current of 18 A.

Q: What is the IP protection rating of the HCS01.1E-W0018-A-03-B-ET-EC-EM-NN-NN-FW?

A: The HCS01.1E-W0018-A-03-B-ET-EC-EM-NN-NN-FW has an IP20 protection rating, offering limited protection against solid objects.

Q: What mains voltage does the HCS01.1E-W0018-A-03-B-ET-EC-EM-NN-NN-FW operate with?

A: This drive controller requires a three-phase AC power supply ranging from 200 to 500 V ±10%.


Internal Product Review

  • ‘‘The HCS01.1E-W0018-A-03-B-ET-EC-EM-NN-NN-FW is an HCS drive controller with MultiEthernet communication and a BASIC control section. Internal blower cooling and IP20 protection support clean, stable cabinet integration in automated equipment. A 3 x AC 200...500 V input range pairs well with 18 A peak current capability, making this controller a strong performer for flexible IndraDrive applications.’’