HCS01.1E-W0018-A-03-B-ET-EC-EM-L4-NN-FW Bosch Rexroth Indramat
MPN: R911337325
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat HCS01.1E-W0018-A-03-B-ET-EC-EM-L4-NN-FW is part of the HCS IndraDrive Controllers series and is a drive controller with a device peak current of 18 Amps. It features MultiEthernet communication, encoder interfaces for IndraDyn Hiperface and EnDat 2.1/2.2, and comes with STO and SBC safety interfaces. This controller uses internal air cooling through an integrated blower and has an IP20 protection rating.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The HCS01.1E-W0018-A-03-B-ET-EC-EM-L4-NN-FW drive controller is produced by Bosch Rexroth Indramat within the HCS IndraDrive Controllers series. It combines a power section and a control section to operate servo and induction motors in automated assembly lines, packaging equipment, and material-handling stations. This arrangement lets the controller convert incoming motion commands into regulated motor output while coordinating current, speed, and position control in one unit. It is suited for compact and modular machine layouts where drive functions are grouped within the IndraDrive platform.
Its communication layer is based on the MultiEthernet interface, so one drive platform can operate on EtherNet/IP, PROFINET, or EtherCAT networks. The power stage accepts a three-phase supply of 3 x AC 200 to 500 V with a tolerance of ±10%. During acceleration, the drive can source up to 18 A of peak current, which supports short periods of higher motor demand. The enclosure protection is IP20, so the unit must be installed inside a suitable cabinet. For closed-loop positioning, the control section supports an IndraDyn Hiperface/EnDat 2.1/2.2 encoder input, and an internal blower moves air through the heatsink to manage operating temperature.
The controller belongs to the HCS01 line and is equipped with a BASIC control section in design version 1, which suits single-axis applications that do not require expanded PLC functions inside the drive. It focuses on drive operation and networked motion tasks rather than standalone machine control. The DC bus connection uses an Infeeding / Feeded topology, so the unit can exchange energy with a common bus during regenerative braking and during periods of higher demand. A secondary feedback port provides encoder emulation, allowing downstream devices or external interface cards to receive incremental signals without an additional sensor. Functional safety is handled through STO and SBC channels, which remove torque or command the motor brake when required.
Frequently Asked Questions about HCS01.1E-W0018-A-03-B-ET-EC-EM-L4-NN-FW:
Q: What communication interface is available on the HCS01.1E-W0018-A-03-B-ET-EC-EM-L4-NN-FW controller?
A: The HCS01.1E-W0018-A-03-B-ET-EC-EM-L4-NN-FW drive controller communicates via a MultiEthernet interface, supporting various industrial networks.
Q: What cooling method does the HCS01.1E-W0018-A-03-B-ET-EC-EM-L4-NN-FW use?
A: This model is designed with an internal air-cooling system that uses an integrated blower for temperature control.
Q: What is the peak current of the HCS01.1E-W0018-A-03-B-ET-EC-EM-L4-NN-FW controller?
A: The device peak current for the HCS01.1E-W0018-A-03-B-ET-EC-EM-L4-NN-FW is rated at 18 A.
Q: What safety features are provided on the HCS01.1E-W0018-A-03-B-ET-EC-EM-L4-NN-FW controller?
A: The safety interface on this drive controller includes both STO (Safe Torque Off) and SBC (Safe Brake Control) functions.
Q: What is the IP rating for the HCS01.1E-W0018-A-03-B-ET-EC-EM-L4-NN-FW drive controller?
A: The HCS01.1E-W0018-A-03-B-ET-EC-EM-L4-NN-FW has an IP20 rating, making it suitable for installation in protected electrical cabinets.