4.95 based on 202 reviews

🙶 We have never had a problem in the almost 20 years we have dealt with Wake. We would recommend them to any... 🙷

HCS01.1E-W0018-A-03-B-ET-EC-EC-NN-NN-NN-FW Bosch Rexroth Indramat

In-Stock, Ships 3-5 Days

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0018-A-03-B-ET-EC-EC-NN-NN-NN-FW is part of the HCS IndraDrive Controllers series. This drive controller features a MultiEthernet communication interface and supports encoder interfaces such as IndraDyn Hiperface and EnDat 2.1/2.2. It has a device peak current of 18 Amps, an IP20 rating, and uses internal air cooling through an integrated blower.

Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0018-A-03-B-ET-EC-EC-NN-NN-NN-FW is a compact drive controller manufactured by Bosch Rexroth Indramat and assigned to the HCS IndraDrive Controllers series. It acts as the power and control interface between the mains supply and synchronous or asynchronous servo motors used in automated material handling, packaging stations, and assembly lines. By executing velocity and position commands while monitoring feedback signals, the unit keeps motor operation under closed-loop control during automated motion tasks. That control loop helps the drive correct load changes, speed variation, and commanded stops without relying on open-loop motor behavior.

This controller connects to higher-level PLCs over the MultiEthernet network, allowing integrated diagnostics and parameter exchange across standard industrial protocols. The power stage accepts a three-phase supply of 3 x AC 200…500 V ±10%, covering both 230 V and 400 V plant grids without a separate transformer. Cooling is provided by internal air cooling through an integrated blower, so no external ducting is necessary for rated operation. With a device peak current of 18 A, the unit can produce short-term torque bursts to accelerate mid-size servo axes. The housing carries an IP20 rating, so it should be installed inside a control cabinet to protect it from dust and liquid exposure.

The control section installed is the BASIC variant, and the unit is Design Version 1. This arrangement provides standard motion functions without adding extra option layers to the control section. Power is managed through a common DC bus, so regenerated energy from braking axes can be buffered or passed to other connected drive units. Dual feedback channels use IndraDyn Hiperface/EnDat 2.1/2.2 encoder feedback, permitting simultaneous connection of two motor encoders for synchronized control or redundant feedback handling. Separate feedback paths can also support applications that need primary motor position data together with an additional encoder signal for monitored axis movement.

Communication Interface
MultiEthernet
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
18 A
Firmware Order Note
Standard or Not Specified
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Safety Interface
Not equipped

Frequently Asked Questions about HCS01.1E-W0018-A-03-B-ET-EC-EC-NN-NN-NN-FW:

Q: What communication interface is available on the HCS01.1E-W0018-A-03-B-ET-EC-EC-NN-NN-NN-FW drive controller?

A: The HCS01.1E-W0018-A-03-B-ET-EC-EC-NN-NN-NN-FW supports MultiEthernet communication for flexible network integration.

Q: What is the device peak current for the HCS01.1E-W0018-A-03-B-ET-EC-EC-NN-NN-NN-FW?

A: This drive controller has a device peak current rating of 18 A, allowing for high-power operation cycles.

Q: How is the HCS01.1E-W0018-A-03-B-ET-EC-EC-NN-NN-NN-FW drive controller cooled?

A: The HCS01.1E-W0018-A-03-B-ET-EC-EC-NN-NN-NN-FW is cooled internally using an integrated blower for air circulation.

Q: What is the IP rating of the HCS01.1E-W0018-A-03-B-ET-EC-EC-NN-NN-NN-FW?

A: This model has an IP20 rating, providing basic protection against solid foreign objects but not water.

Q: What mains voltage is supported by the HCS01.1E-W0018-A-03-B-ET-EC-EC-NN-NN-NN-FW drive controller?

A: The HCS01.1E-W0018-A-03-B-ET-EC-EC-NN-NN-NN-FW works with a mains voltage supply of 3 x AC 200 to 500 V with a 10% tolerance.


Internal Product Review

  • ‘‘The HCS01.1E-W0018-A-03-B-ET-EC-EC-NN-NN-NN-FW is an HCS Drive Controller with MultiEthernet communication and a BASIC control section. Internal blower cooling and dual IndraDyn Hiperface/EnDat 2.1/2.2 encoder interfaces support stable thermal performance and flexible feedback integration. IP20 protection and 18 A peak current make the unit a strong choice for industrial drive applications.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo