The Bosch Rexroth Indramat HCS01.1E-W0018-A-03-B-ET-EC-EC-NN-AA-FW is a drive controller from the HCS IndraDrive Controllers series, featuring a MultiEthernet communication interface and an IP20 rating. This device has a peak current of 18 Amps, uses internal air cooling through an integrated blower, and supports encoder interfaces IndraDyn Hiperface and EnDat 2.1/2.2.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0018-A-03-B-ET-EC-EC-NN-AA-FW drive controller is manufactured by Bosch Rexroth Indramat and belongs to the HCS IndraDrive Controllers series. Within an automated cell, it acts as the regulated power stage that converts DC-bus energy into controlled three-phase output for servo axes. The device executes drive-based control loops, receives motion commands from higher-level PLCs, and returns status data for coordinated positioning. This allows the connected motor to follow acceleration, deceleration, and holding commands with stable current regulation during repetitive machine cycles. Its role supports indexing conveyors, form-fill-seal stations, and pick-and-place gantries where tight speed and position tolerances are required.

The control section is classified as BASIC, so standard motion functions are available without optional technology extensions. All command traffic and diagnostics travel over MultiEthernet, enabling connection to EtherNet/IP, PROFINET, EtherCAT, or SERCOS III networks through the same port. The power stage can deliver up to 18 A of device peak current, a short-term reserve that helps the motor overcome inertia during acceleration. Heat produced at that current level is removed by internal air cooling through an integrated blower, avoiding external cooling ducts. The AC input accepts 3 x AC 200…500 V ±10%, allowing the drive to operate on both 230 V and 460 V plant supplies. The wide input range also helps the unit fit mixed-voltage facilities without changes to its core control functions.

The housing carries an IP20 rating, so installation inside a protective cabinet is required while finger-safe access to terminals is maintained. Two feedback sockets are prepared for IndraDyn Hiperface or EnDat 2.1/2.2 encoder feedback, giving high-resolution position data to the drive without additional interface cards. DC-bus energy sharing is supported by infeeding and shared DC-bus operation, which allows several drives to draw power from or return power to a common source. This arrangement supports compact multi-axis cabinets that use a shared supply and separate safety hardware. The unit is Design Version 1, and no internal safety interface is installed, so external STO wiring is required.

Communication Interface
MultiEthernet
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
18 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Safety Interface
Not equipped
  • HCS011EW0018A03BETECECNNAAFW
  • HCS01 1E W0018 A 03 B ET EC EC NN AA FW
  • hcs01.1e-w0018-a-02-b-et-ec-pb-l3-nn-fw
  • HCS1.1E-W0018-A-03-B-ET-EC-EC-NN-AA-FW

Frequently Asked Questions about HCS01.1E-W0018-A-03-B-ET-EC-EC-NN-AA-FW:

Q: What type of communication interface is available on the HCS01.1E-W0018-A-03-B-ET-EC-EC-NN-AA-FW controller?

A: The HCS01.1E-W0018-A-03-B-ET-EC-EC-NN-AA-FW supports MultiEthernet for communication flexibility.

Q: How is the HCS01.1E-W0018-A-03-B-ET-EC-EC-NN-AA-FW cooled during operation?

A: This drive controller is equipped with an internal air cooling system using an integrated blower.

Q: What is the peak current rating for the HCS01.1E-W0018-A-03-B-ET-EC-EC-NN-AA-FW model?

A: The drive controller can deliver a peak device current of 18 A.

Q: What level of ingress protection does the HCS01.1E-W0018-A-03-B-ET-EC-EC-NN-AA-FW offer?

A: This model has an IP20 rating, providing limited protection against solid objects.

Q: What mains voltage input is supported by the HCS01.1E-W0018-A-03-B-ET-EC-EC-NN-AA-FW drive controller?

A: The HCS01.1E-W0018-A-03-B-ET-EC-EC-NN-AA-FW supports mains voltages from 3 x AC 200 to 500 V ±10%.