4.95 based on 202 reviews

🙶 We have never had a problem in the almost 20 years we have dealt with Wake. We would recommend them to any... 🙷

HCS01.1E-W0018-A-03-B-ET-EC-EC-L3-NN-FW Bosch Rexroth Indramat

MPN: R911341247

No Tariffs On US Orders
  • Rated 4.4 (39 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
In-Stock, Ships 3-5 Days

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0018-A-03-B-ET-EC-EC-L3-NN-FW is an HCS Drive Controller from the HCS IndraDrive Controllers series. It supports a peak current of 18 Amps and operates with a MultiEthernet communication interface. This controller features STO safety, uses internal air cooling with an integrated blower, and has an IP20 protection rating.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0018-A-03-B-ET-EC-EC-L3-NN-FW is a power section in the Bosch Rexroth Indramat HCS IndraDrive Controllers series. As an HCS01 drive controller, it receives three-phase mains power and modulates voltage and frequency to command servo or induction motors, forming the core of positioning, conveying, or packaging axes. Within an automation cell, the module links the machine motion layer with supervisory PLCs, supplying precise torque and speed while the matching control section handles loop processing and parameter management for coordinated axis behavior. This arrangement keeps the power stage separate from the control electronics and supports flexible machine layouts.

Incoming line power of 3 x AC 200...500 V ±10% is accepted, and the converter can momentarily deliver up to 18 A of peak current to the motor windings. Heat is removed by internal air cooling driven by an integrated blower, so no external ducting is required inside the cabinet. For fieldbus and diagnostic data, the control electronics provide a MultiEthernet port that supports several industrial Ethernet protocols through a single connector. The IP20 enclosure rating requires installation inside a switchgear cabinet and protects against accidental contact with internal live parts.

The converter is paired with a control section classified as BASIC, which matches this hardware class. The drive also integrates STO (Safe Torque Off) circuits that remove torque-producing power during an emergency stop. Two identical feedback ports accept IndraDyn Hiperface or EnDat 2.1/2.2 encoder signals, allowing direct use of compatible absolute encoders without extra adapter boards. This supports closed-loop positioning without additional interface cards. Energy exchange with the DC bus uses infeeding and regenerative operation, so the unit can draw power from or return power to a shared supply.

Communication Interface
MultiEthernet
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
18 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Safety Interface
STO (Safe Torque Off)
  • HCS011EW0018A03BETECECL3NNFW
  • HCS01 1E W0018 A 03 B ET EC EC L3 NN FW
  • hcs01.1e-w0018-a-02-b-et-ec-nn-s5-nn-fw
  • HCS1.1E-W0018-A-03-B-ET-EC-EC-L3-NN-FW

Frequently Asked Questions about HCS01.1E-W0018-A-03-B-ET-EC-EC-L3-NN-FW:

Q: What is the peak current capacity of the HCS01.1E-W0018-A-03-B-ET-EC-EC-L3-NN-FW drive controller?

A: The HCS01.1E-W0018-A-03-B-ET-EC-EC-L3-NN-FW controller has a device peak current rating of 18 A.

Q: What type of communication interface does the HCS01.1E-W0018-A-03-B-ET-EC-EC-L3-NN-FW model offer?

A: This controller supports MultiEthernet communication interface for network connectivity.

Q: How is the HCS01.1E-W0018-A-03-B-ET-EC-EC-L3-NN-FW drive controller cooled?

A: The cooling method for this model is air cooling through an integrated internal blower.

Q: What is the mains voltage range for the HCS01.1E-W0018-A-03-B-ET-EC-EC-L3-NN-FW?

A: The unit operates within a main voltage range of 3 x AC 200 to 500 V, with a ±10% tolerance.

Q: What safety interface is included on the HCS01.1E-W0018-A-03-B-ET-EC-EC-L3-NN-FW drive controller?

A: This controller features STO (Safe Torque Off) as its safety interface.


Internal Product Review

  • ‘‘The HCS01.1E-W0018-A-03-B-ET-EC-EC-L3-NN-FW is an HCS drive controller with MultiEthernet communication and a BASIC control section. Internal air cooling through an integrated blower and IP20 protection support dependable cabinet operation in demanding automation panels. An 18 A peak current rating with 3 x AC 200 to 500 V mains input makes the controller a strong choice for flexible drive integration.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo