Ask for AvailabilityThe Bosch Rexroth Indramat HCS01.1E-W0018-A-03-A-ET-EC-EC-S5-NN-FW is a drive controller from the HCS IndraDrive Controllers series. It features a MultiEthernet communication interface, supports a peak current of 18 Amps, and has an air cooling system with an integrated blower. The controller offers IP20 protection and operates on a mains voltage of 3 x AC 200 to 500 Volts.
Internal Product Review
The HCS01.1E-W0018-A-03-A-ET-EC-EC-S5-NN-FW is an HCS Drive Controller with MultiEthernet communication that fits well into modern motion platforms. Internal blower cooling and IP20 protection support stable cabinet operation and dependable thermal management. With 18 A peak current and a 3 x AC 200 to 500 V input range, this unit stands out as a capable choice for demanding drive applications.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The HCS01.1E-W0018-A-03-A-ET-EC-EC-S5-NN-FW is a drive controller produced by Bosch Rexroth Indramat in the HCS IndraDrive Controllers series. It forms the interface between a plant PLC and a connected servo or induction motor, closing current, speed, and position loops for automated machinery, packaging lines, and handling cells. By integrating power electronics, motion control, and encoder processing in one compact housing, it simplifies cabinet layouts and reduces the number of separate devices in the panel. This arrangement supports coordinated motor control while keeping the drive and feedback functions in a single module.
Electrical flexibility is provided by a supply window of 3 x AC 200...500 V ±10%, so the controller can operate from either 230 V or 460 V plant distribution. The internal power stage delivers a peak motor current of 18 A for short acceleration bursts. Thermal management relies on internal air cooling through an integrated blower, which pushes cabinet air across the heat sink to maintain operating temperature. The housing carries an IP20 rating, so it is finger-safe but requires installation inside an enclosure. Command and diagnostic data travel through MultiEthernet, allowing direct use on PROFINET, EtherNet/IP, or EtherCAT through the control interface.
The unit is built in Design Version 1 and belongs to the HCS01 line. The power section uses infeeding and fed operation, allowing regenerated energy to return to the DC link or be used locally within the system. Both feedback ports support IndraDyn Hiperface and EnDat 2.1/2.2 encoders, providing high-resolution position data for compatible Rexroth motors. It is intended to pair with a BASIC control section, and the integrated feedback handling supports accurate closed-loop motor operation across positioning and speed-control tasks.