4.95 based on 202 reviews

🙶 Product was as advertised, got the machine back up and running at a fraction of OEM price. Delivered on ti... 🙷

HCS01.1E-W0018-A-03-A-ET-EC-EC-S5-NN-FW Bosch Rexroth Indramat

MPN: R911384894

No Tariffs On US Orders
  • Rated 4.5 (61 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0018-A-03-A-ET-EC-EC-S5-NN-FW is a drive controller from the HCS IndraDrive Controllers series. It features a MultiEthernet communication interface, supports a peak current of 18 Amps, and has an air cooling system with an integrated blower. The controller offers IP20 protection and operates on a mains voltage of 3 x AC 200 to 500 Volts.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0018-A-03-A-ET-EC-EC-S5-NN-FW is a drive controller produced by Bosch Rexroth Indramat in the HCS IndraDrive Controllers series. It forms the interface between a plant PLC and a connected servo or induction motor, closing current, speed, and position loops for automated machinery, packaging lines, and handling cells. By integrating power electronics, motion control, and encoder processing in one compact housing, it simplifies cabinet layouts and reduces the number of separate devices in the panel. This arrangement supports coordinated motor control while keeping the drive and feedback functions in a single module.

Electrical flexibility is provided by a supply window of 3 x AC 200...500 V ±10%, so the controller can operate from either 230 V or 460 V plant distribution. The internal power stage delivers a peak motor current of 18 A for short acceleration bursts. Thermal management relies on internal air cooling through an integrated blower, which pushes cabinet air across the heat sink to maintain operating temperature. The housing carries an IP20 rating, so it is finger-safe but requires installation inside an enclosure. Command and diagnostic data travel through MultiEthernet, allowing direct use on PROFINET, EtherNet/IP, or EtherCAT through the control interface.

The unit is built in Design Version 1 and belongs to the HCS01 line. The power section uses infeeding and fed operation, allowing regenerated energy to return to the DC link or be used locally within the system. Both feedback ports support IndraDyn Hiperface and EnDat 2.1/2.2 encoders, providing high-resolution position data for compatible Rexroth motors. It is intended to pair with a BASIC control section, and the integrated feedback handling supports accurate closed-loop motor operation across positioning and speed-control tasks.

Communication Interface
MultiEthernet
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
18 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
  • HCS011EW0018A03AETECECS5NNFW
  • HCS01 1E W0018 A 03 A ET EC EC S5 NN FW
  • hcs01.1e-w0018-a-02-b-et-ec-ec-l4-nn-fw
  • HCS1.1E-W0018-A-03-A-ET-EC-EC-S5-NN-FW

Frequently Asked Questions about HCS01.1E-W0018-A-03-A-ET-EC-EC-S5-NN-FW:

Q: What communication interface is available on the HCS01.1E-W0018-A-03-A-ET-EC-EC-S5-NN-FW controller?

A: This drive controller supports MultiEthernet communication for flexible integration into various network environments.

Q: How is the HCS01.1E-W0018-A-03-A-ET-EC-EC-S5-NN-FW cooled?

A: It uses an internal air cooling method with an integrated blower.

Q: What is the device peak current of the HCS01.1E-W0018-A-03-A-ET-EC-EC-S5-NN-FW?

A: The drive controller delivers a peak current of 18 A for demanding applications.

Q: What level of protection does the IP20 rating provide for this controller?

A: The HCS01.1E-W0018-A-03-A-ET-EC-EC-S5-NN-FW has an IP20 rating, which means it is protected against solid objects greater than 12.5 mm in size.

Q: What control section design should the HCS01.1E-W0018-A-03-A-ET-EC-EC-S5-NN-FW be paired with?

A: It must be paired with a Control Section Design 'BASIC' (B), as indicated in the product specifications.


Internal Product Review

  • ‘‘The HCS01.1E-W0018-A-03-A-ET-EC-EC-S5-NN-FW is an HCS Drive Controller with MultiEthernet communication that fits well into modern motion platforms. Internal blower cooling and IP20 protection support stable cabinet operation and dependable thermal management. With 18 A peak current and a 3 x AC 200 to 500 V input range, this unit stands out as a capable choice for demanding drive applications.’’