The Bosch Rexroth Indramat HCS01.1E-W0018-A-03-A-CC-EC-PB-S4-NN-FW is an HCS IndraDrive Controller featuring a SERCOS III master communication interface and integrated PROFIBUS connectivity. This drive controller is designed with the ADVANCED control section, offers a device peak current of 18 Amps, and uses air cooling through an internal blower. It supports encoder interfaces such as IndraDyn Hiperface and EnDat 2.1/2.2, and has an IP20 rating.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0018-A-03-A-CC-EC-PB-S4-NN-FW is a drive controller produced by Bosch Rexroth Indramat within the HCS IndraDrive Controllers series. It serves as the regulated power interface between a three-phase mains supply and IndraDyn servo motors, managing speed, torque, and position loops in automated assembly lines, packaging stations, and material-handling cells. By integrating power electronics, axis control, and fieldbus communication into one compact unit, the controller streamlines cabinet layouts and reduces wiring for multi-axis machinery. This arrangement allows the controller to generate motor current and process closed-loop motion control functions inside the same housing.

The unit accepts a three-phase supply of 3 x AC 200…500 V ±10% and can deliver up to 18 A of device peak current to a connected motor. Thermal energy is removed by internal blower cooling, eliminating the need for external fans. The housing carries an IP20 rating, so the unit is intended for installation inside a protected control cabinet. Axis timing and parameter data are exchanged through SERCOS III master cross communication, which allows several controllers on the same system to synchronize motion without an added gateway. The compact enclosure helps fit the drive into dense cabinet layouts where multiple axes share limited panel space.

Control logic is supplied by the ADVANCED section, which is factory matched to the power stage. Motor feedback enters through the IndraDyn Hiperface/EnDat 2.1/2.2 interface, while plant-level commands travel over PROFIBUS. The power module follows an infeeding and fed topology, so regenerated energy can be shared across the DC bus when several axes decelerate at the same time. This combination allows the controller to receive network commands from the machine control while also processing feedback from compatible motor encoders. Shared DC-bus operation can also reduce the amount of braking energy that must be dissipated locally during coordinated motion.

Communication Interface
SERCOS III master (cross communication)
Control Section Design Type
ADVANCED
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
18 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
PROFIBUS
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'ADVANCED' (A)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
  • HCS011EW0018A03ACCECPBS4NNFW
  • HCS01 1E W0018 A 03 A CC EC PB S4 NN FW
  • hcs01.1e-w0018-a-02-a-et-ec-nn-nn-nn-fw
  • HCS1.1E-W0018-A-03-A-CC-EC-PB-S4-NN-FW

Frequently Asked Questions about HCS01.1E-W0018-A-03-A-CC-EC-PB-S4-NN-FW:

Q: What communication interface does the HCS01.1E-W0018-A-03-A-CC-EC-PB-S4-NN-FW provide?

A: The HCS01.1E-W0018-A-03-A-CC-EC-PB-S4-NN-FW supports a SERCOS III master interface for cross communication capabilities.

Q: How is the HCS01.1E-W0018-A-03-A-CC-EC-PB-S4-NN-FW cooled?

A: This model is equipped with an integrated blower for internal air cooling.

Q: What is the peak current capability of the HCS01.1E-W0018-A-03-A-CC-EC-PB-S4-NN-FW?

A: The device handles a peak current of up to 18 A during operation.

Q: What level of environmental protection does the HCS01.1E-W0018-A-03-A-CC-EC-PB-S4-NN-FW offer?

A: The HCS01.1E-W0018-A-03-A-CC-EC-PB-S4-NN-FW has an IP20 ingress protection rating, which limits exposure to dust but is not protected against water.

Q: What mains voltage range does the HCS01.1E-W0018-A-03-A-CC-EC-PB-S4-NN-FW support?

A: The mains voltage range for this controller is 3 x AC 200 to 500 V with a ±10% tolerance.


Internal Product Review

  • ‘‘The HCS01.1E-W0018-A-03-A-CC-EC-PB-S4-NN-FW is a Bosch Rexroth Indramat HCS drive controller with an ADVANCED control section, giving the unit a very capable motion-control profile. SERCOS III master cross communication and a PROFIBUS interface support clean network integration across coordinated drive architectures. An 18 A peak current rating adds strong dynamic capability for demanding servo applications.’’