4.95 based on 202 reviews

🙶 Excellent to work with and they stand behind their work. I would highly recommend them. 🙷

HCS01.1E-W0018-A-03-A-CC-EC-PB-L3-NN-FW Bosch Rexroth Indramat

MPN: R911341038

No Tariffs On US Orders
  • Rated 4.6 (46 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
In-Stock, Ships Fast

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0018-A-03-A-CC-EC-PB-L3-NN-FW is a HCS IndraDrive Controllers series drive controller with a device peak current of 18 Amps. It supports a SERCOS III master communication interface and has encoder and PROFIBUS interfaces. The unit is internally cooled with an integrated blower, operates with a mains voltage range of 200 to 500 Volts AC, and has an IP20 rating.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0018-A-03-A-CC-EC-PB-L3-NN-FW is a drive controller manufactured by Bosch Rexroth Indramat within the HCS IndraDrive Controllers series. It regulates torque, speed, and position for IndraDyn servo and spindle motors used in automated assembly lines, material-handling modules, and packaging machines. The unit combines a regulated power stage with an interchangeable control section, allowing it to act as a coordinated axis controller in multi-axis systems. It also supplies precisely timed three-phase output while exchanging real-time status data with the higher-level controller. This arrangement supports machines that require synchronized motion across several independent axes.

The controller is rated for 3 x AC 200 to 500 V ±10%, so it can operate from common 230 V or 400 V factory mains without a transformer. During acceleration or braking, it can supply up to 18 A of peak current, which supports short dynamic load changes without unnecessary interruption. Thermal management uses internal air cooling with an integrated blower, and the blower moves cabinet air across the heat sink to keep power devices within safe limits. The fitted control section is the ADVANCED variant, which adds extended motion functions and nonvolatile parameter memory beyond the basic level. Command and status data are exchanged through a SERCOS III master with cross communication, and the power module supports both infeeding and fed operation with design version 1.

For motor feedback, the drive accepts IndraDyn encoder feedback with Hiperface or EnDat 2.1/2.2, so it can process position signals from compatible motor systems. A dedicated fieldbus channel communicates over PROFIBUS, allowing cyclic process data exchange with existing PLC platforms. Functional safety is implemented with STO (Safe Torque Off), which blocks gate signals to the output transistors when activated so the motor cannot produce torque. The housing has an IP20 rating, which provides finger-safe protection and requires installation inside an enclosure because it is not sealed against liquids. Because the housing depends on cabinet protection, the surrounding panel must provide controlled airflow and keep out moisture.

Communication Interface
SERCOS III master (cross communication)
Control Section Design Type
ADVANCED
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
18 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
PROFIBUS
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'ADVANCED' (A)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Safety Interface
STO (Safe Torque Off)
  • HCS011EW0018A03ACCECPBL3NNFW
  • HCS01 1E W0018 A 03 A CC EC PB L3 NN FW
  • hcs01.1e-w0018-a-02-a-et-ec-em-s4-nn-fw
  • HCS1.1E-W0018-A-03-A-CC-EC-PB-L3-NN-FW

Frequently Asked Questions about HCS01.1E-W0018-A-03-A-CC-EC-PB-L3-NN-FW:

Q: What cooling method does the HCS01.1E-W0018-A-03-A-CC-EC-PB-L3-NN-FW use?

A: This drive controller uses an integrated blower for internal air cooling.

Q: What is the device peak current of the HCS01.1E-W0018-A-03-A-CC-EC-PB-L3-NN-FW controller?

A: The peak current rating for this model is 18 amps.

Q: Which communication interface is included on the HCS01.1E-W0018-A-03-A-CC-EC-PB-L3-NN-FW?

A: This controller has a SERCOS III master interface supporting cross communication.

Q: What mains voltage is supported by the HCS01.1E-W0018-A-03-A-CC-EC-PB-L3-NN-FW drive controller?

A: The main supply voltage for this unit ranges from 3 x AC 200 to 500 V ±10%.

Q: What safety interface is provided on the HCS01.1E-W0018-A-03-A-CC-EC-PB-L3-NN-FW model?

A: This controller is equipped with a Safe Torque Off (STO) safety interface.


Internal Product Review

  • ‘‘The HCS01.1E-W0018-A-03-A-CC-EC-PB-L3-NN-FW is an HCS drive controller with ADVANCED control architecture. Internal air cooling from the integrated blower and SERCOS III master cross communication support efficient integration in demanding motion platforms. STO Safe Torque Off adds valuable protection for safety-focused drive systems.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo