4.95 based on 202 reviews

🙶 We have never had a problem in the almost 20 years we have dealt with Wake. We would recommend them to any... 🙷

HCS01.1E-W0018-A-03-A-CC-EC-NN-S5-NN-FW Bosch Rexroth Indramat

MPN: R911386157

No Tariffs On US Orders
  • Rated 4.6 (38 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0018-A-03-A-CC-EC-NN-S5-NN-FW is an HCS Drive Controller in the HCS IndraDrive Controllers series. It features an ADVANCED control section and supports SERCOS III master cross communication, with a device peak current of 18 Amps. Internal air cooling is provided through an integrated blower, and the controller operates at a mains voltage of 3 x AC 200 to 500 Volts with an IP20 rating.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0018-A-03-A-CC-EC-NN-S5-NN-FW drive controller is built by Bosch Rexroth Indramat as part of the HCS IndraDrive Controllers series. It serves as the power and control stage for servo and induction motor axes, converting incoming three-phase power into regulated motor current while exchanging motion commands with higher-level PLCs. In automated equipment, it supports precise velocity and position control for packaging stations, handling gantries, and compact machining modules. This role lets the unit manage repeatable cycles and controlled acceleration without adding separate axis control hardware for each drive point.

The unit accepts a supply of 3 × AC 200…500 V ±10%, which allows connection to common industrial mains across a wide input range. Heat is removed by internal air cooling through an integrated blower, so cabinet air is circulated across the heat sink without external ducting. During dynamic acceleration, the power stage can deliver a peak output of 18 A for short periods before returning to its continuous operating range. The enclosure is rated IP20, so the drive must be installed inside a closed electrical cabinet. For networked motion control, it uses a SERCOS III master with cross communication interface to support deterministic timing in synchronized multi-axis systems.

The control section uses the ADVANCED control variant, which provides expanded axis regulation functions and parameter memory. Motor feedback is handled through an IndraDyn Hiperface/EnDat 2.1/2.2 encoder interface, allowing compatible feedback devices to supply position data for closed-loop operation. Energy is managed through an infeeding and fed power supply topology, so regenerative power can be shared on a common DC bus instead of being sent directly to braking resistors. The unit is identified as design version 1, indicating the first mechanical and electrical release of this controller type.

Communication Interface
SERCOS III master (cross communication)
Control Section Design Type
ADVANCED
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
18 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Not equipped
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'ADVANCED' (A)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
  • HCS011EW0018A03ACCECNNS5NNFW
  • HCS01 1E W0018 A 03 A CC EC NN S5 NN FW
  • hcs01.1e-w0018-a-02-a-et-ec-da-nn-nn-fw
  • HCS1.1E-W0018-A-03-A-CC-EC-NN-S5-NN-FW

Frequently Asked Questions about HCS01.1E-W0018-A-03-A-CC-EC-NN-S5-NN-FW:

Q: What is the peak current capability of the HCS01.1E-W0018-A-03-A-CC-EC-NN-S5-NN-FW drive controller?

A: This controller has a device peak current rating of 18 A, allowing for handling of moderate load applications.

Q: How is the HCS01.1E-W0018-A-03-A-CC-EC-NN-S5-NN-FW drive controller cooled?

A: The HCS01.1E-W0018-A-03-A-CC-EC-NN-S5-NN-FW uses an integrated blower for internal air cooling.

Q: What communication interface is included on the HCS01.1E-W0018-A-03-A-CC-EC-NN-S5-NN-FW?

A: This model is equipped with a SERCOS III master interface that supports cross communication.

Q: What is the mains voltage range required for the HCS01.1E-W0018-A-03-A-CC-EC-NN-S5-NN-FW?

A: The controller operates on a mains voltage of 3 x AC 200...500 V ±10%.

Q: What level of protection does the HCS01.1E-W0018-A-03-A-CC-EC-NN-S5-NN-FW provide according to its IP rating?

A: The IP20 rating of this drive controller means it is protected against solid objects larger than 12.5 mm but not against water.


Internal Product Review

  • ‘‘The HCS01.1E-W0018-A-03-A-CC-EC-NN-S5-NN-FW is an HCS drive controller with an ADVANCED control section and SERCOS III master cross communication. Air cooling through an integrated blower and a 3 x AC 200 to 500 V input support dependable integration in demanding drive systems. An 18 A peak current rating with IP20 protection makes the unit a strong choice for precise industrial motion control.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo