The Bosch Rexroth Indramat HCS01.1E-W0018-A-03-A-CC-EC-EM-L4-NN-FW is part of the HCS IndraDrive Controllers series. This ADVANCED drive controller uses SERCOS III master cross communication and supports encoder interfaces like IndraDyn Hiperface and EnDat 2.1/2.2. It features air cooling through an internal blower, a device peak current of 18 Amps, and an IP20 rating.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0018-A-03-A-CC-EC-EM-L4-NN-FW is a Bosch Rexroth Indramat drive controller from the HCS IndraDrive Controllers series. Positioned in the HCS01 line, it combines a power section with a pluggable control section to convert incoming AC power into regulated output for synchronous and asynchronous motors. Within industrial automation cells, the unit provides speed, torque, and position control loops that support coordinated multi-axis motion while keeping cabinet depth and installation space low.

Motion commands and diagnostic data are exchanged through the built-in SERCOS III master with cross communication interface, so the controller can synchronize with other axes on the optical ring without separate gateway hardware. The paired control section is the ADVANCED variant, which supports user-selectable technology functions and parameter storage on an SD card. During acceleration, the power stage can deliver a device peak current of 18 A, giving short-term overload capacity for high-inertia loads. The mains side accepts 3 × AC 200…500 V ±10%, allowing the same model to operate on 230 V or 480 V plant supplies without a step-down transformer. Heat is removed by internal air cooling through an integrated blower, so no external heat sink or liquid loop is required.

For safer machine integration, the power section incorporates the dual-channel safety functions STO and SBC. This arrangement shuts off torque and controls brake actuation when the safety circuit opens. High-resolution feedback is accepted through the IndraDyn Hiperface/EnDat 2.1/2.2 encoder interface, while legacy equipment or diagnostic devices can be connected through the secondary encoder emulation output. The IP20 housing allows installation in protected switchgear enclosures, where the controller can be integrated with other cabinet-mounted automation hardware.

Communication Interface
SERCOS III master (cross communication)
Control Section Design Type
ADVANCED
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
18 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Encoder emulation
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'ADVANCED' (A)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Safety Interface
STO (Safe Torque Off) and SBC (Safe Brake Control)
  • HCS011EW0018A03ACCECEML4NNFW
  • HCS01 1E W0018 A 03 A CC EC EM L4 NN FW
  • hcs01.1e-w0018-a-02-a-cc-ec-em-nn-nn-fw
  • HCS1.1E-W0018-A-03-A-CC-EC-EM-L4-NN-FW

Frequently Asked Questions about HCS01.1E-W0018-A-03-A-CC-EC-EM-L4-NN-FW:

Q: What communication interface is available on the HCS01.1E-W0018-A-03-A-CC-EC-EM-L4-NN-FW drive controller?

A: The HCS01.1E-W0018-A-03-A-CC-EC-EM-L4-NN-FW supports the SERCOS III master communication interface with cross communication capabilities.

Q: How is the HCS01.1E-W0018-A-03-A-CC-EC-EM-L4-NN-FW cooled?

A: This drive controller uses an internal air cooling method with an integrated blower for temperature regulation.

Q: What is the peak current rating for the HCS01.1E-W0018-A-03-A-CC-EC-EM-L4-NN-FW?

A: The HCS01.1E-W0018-A-03-A-CC-EC-EM-L4-NN-FW offers a device peak current of 18 A for high dynamic operations.

Q: Which safety interfaces are included in the HCS01.1E-W0018-A-03-A-CC-EC-EM-L4-NN-FW model?

A: It features both STO (Safe Torque Off) and SBC (Safe Brake Control) safety interfaces for enhanced operational safety.

Q: What mains voltage does the HCS01.1E-W0018-A-03-A-CC-EC-EM-L4-NN-FW support?

A: The supported mains voltage range for this drive controller is 3 x AC 200 to 500 V ±10%.


Internal Product Review

  • ‘‘The HCS01.1E-W0018-A-03-A-CC-EC-EM-L4-NN-FW is an HCS drive controller with internal air cooling through an integrated blower. SERCOS III master cross communication and IndraDyn Hiperface/EnDat 2.1/2.2 encoder support make the unit especially attractive for precise, networked motion applications. STO and SBC safety functions add strong machine integration value, and the 18 A peak current is a notable performance advantage.’’