4.95 based on 202 reviews

🙶 Great service, they have the parts i needed in stock. 🙷

HCS01.1E-W0018-A-03-A-CC-EC-EC-L4-NN-FW Bosch Rexroth Indramat

MPN: R911337361

Ask for Availability
Current Response Time 3 min 43 sec

The Bosch Rexroth Indramat HCS01.1E-W0018-A-03-A-CC-EC-EC-L4-NN-FW is part of the HCS IndraDrive Controllers series and features an advanced control section design type. This drive controller offers a SERCOS III master communication interface and provides a device peak current of 18 Amps with internal air cooling via an integrated blower. It includes STO Safe Torque Off and SBC Safe Brake Control safety interfaces and an IP20 protection rating.

No Hidden Fees Rush or Credit Card
No Tariffs On US Orders

Internal Product Review

The HCS01.1E-W0018-A-03-A-CC-EC-EC-L4-NN-FW is an HCS drive controller with an ADVANCED control section and internal air cooling. SERCOS III master cross communication and dual Hiperface/EnDat 2.1/2.2 encoder interfaces support precise, well-coordinated motion control. IP20 protection and STO/SBC safety functions make the controller a highly capable choice for advanced drive systems.

Sell Part Have a part to sell?
Warranty Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0018-A-03-A-CC-EC-EC-L4-NN-FW drive controller is produced by Bosch Rexroth Indramat and belongs to the HCS IndraDrive Controllers series. The unit is part of the HCS01 line and is design version 1, placing it within a compact controller platform for servo-axis applications. As an HCS drive controller, it forms the power and control core of industrial motion axes by converting three-phase mains power to a regulated DC link. Within a system, it supports closed-loop torque, speed, and position regulation through its modular control section and coordinated power stage.

Electrical compatibility starts with a three-phase supply of 3 x AC 200...500 V ±10%, letting the hardware fit low- or mid-voltage networks without tap changes. For dynamic events, the inverter delivers up to 18 A of peak phase current matched to small and mid-frame IndraDyn motors. Heat is removed by internal air cooling through an integrated blower, so the cabinet only needs clearance for recirculated airflow around the unit. Protection against accidental contact is limited to an IP20 housing, so the controller is intended for installation inside a closed panel. Motion and parameter data move over a SERCOS III master with cross communication interface, enabling real-time coordination with neighboring drives on the network.

Its control section is ADVANCED, which provides the processing capacity used by this configuration for coordinated servo operation. Two identical inputs accept IndraDyn Hiperface or EnDat 2.1/2.2 encoder signals, allowing redundant motor feedback and compatibility with supported motor feedback systems. Functional safety disables torque through STO (Safe Torque Off) and SBC (Safe Brake Control), supporting safe drive shutdown behavior when required by the machine. The common DC bus supports infeeding and fed operation, so energy can move to and from the drive section during normal operation.

Communication Interface
SERCOS III master (cross communication)
Control Section Design Type
ADVANCED
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
18 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'ADVANCED' (A)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Safety Interface
STO (Safe Torque Off) and SBC (Safe Brake Control)

Frequently Asked Questions about HCS01.1E-W0018-A-03-A-CC-EC-EC-L4-NN-FW:

Q: What communication interface is used by the HCS01.1E-W0018-A-03-A-CC-EC-EC-L4-NN-FW drive controller?

A: The HCS01.1E-W0018-A-03-A-CC-EC-EC-L4-NN-FW uses SERCOS III master for cross communication between devices.

Q: What is the device peak current rating for the HCS01.1E-W0018-A-03-A-CC-EC-EC-L4-NN-FW?

A: This model provides a peak current of 18 A, suitable for applications requiring short bursts of high current.

Q: Which encoder types are supported by the HCS01.1E-W0018-A-03-A-CC-EC-EC-L4-NN-FW drive?

A: It supports encoder connections using IndraDyn Hiperface and EnDat 2.1/2.2 on both interfaces 1 and 2.

Q: How is the HCS01.1E-W0018-A-03-A-CC-EC-EC-L4-NN-FW cooled during operation?

A: Cooling is achieved via an internal air system with an integrated blower for efficient heat dissipation.

Q: What safety interfaces are available on the HCS01.1E-W0018-A-03-A-CC-EC-EC-L4-NN-FW?

A: This drive controller features STO (Safe Torque Off) and SBC (Safe Brake Control) safety interfaces for enhanced operational safety.