4.95 based on 202 reviews

🙶 Wake was very helpful in getting us a servo motor and drive for our tube mill line. This was the first tim... 🙷

HCS01.1E-W0018-A-03-A-CC-EC-CN-S4-NN-FW Bosch Rexroth Indramat

MPN: R911345334

No Tariffs On US Orders
  • Rated 4.4 (43 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0018-A-03-A-CC-EC-CN-S4-NN-FW is an HCS Drive Controller from the HCS IndraDrive Controllers series. It features a peak device current of 18 Amps and operates with an internal air cooling method through an integrated blower. This controller is equipped with SERCOS III master cross communication, an encoder interface for IndraDyn Hiperface or EnDat 2.1/2.2, and a CANopen interface, with an IP20 rating and a mains voltage range of 3 x AC 200 to 500 Volts plus or minus 10%.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0018-A-03-A-CC-EC-CN-S4-NN-FW is a drive controller manufactured by Bosch Rexroth Indramat for the HCS IndraDrive Controllers series. Designed for multi-axis automation, it supplies regulated power to servo motors, monitors feedback signals, and links motion commands to the plant control system. This arrangement allows the controller to support closed-loop motion tasks in compact machine cabinets without requiring a separate control device for each axis.

Real-time axis coordination is handled through the SERCOS III master with cross communication interface, which lets several drives exchange position data without extra gateways. The control electronics use the ADVANCED control section, adding processing capacity for complex motion functions. An internal blower provides air cooling, so no external ducting is required. The drive can deliver up to 18 A of peak output current to support short acceleration bursts before returning to nominal load. It accepts a supply of 3 x AC 200 to 500 V ±10%, allowing use on both 230 V and 460 V power systems. With an enclosure rated at IP20, the unit must be mounted in a protected cabinet while still allowing front access for wiring and service. The HCS01 line identifier indicates the basic platform size for this controller.

Position data is accepted through the IndraDyn Hiperface and EnDat 2.1/2.2 encoder interface, allowing use with standard Rexroth motor feedback systems. Higher-level diagnostics and parameter changes travel on CANopen, which operates alongside the motion bus for service communication. Energy handling relies on an infeeding or fed power supply stage, so the controller can return regenerative energy or draw power from a shared DC bus. The unit is Design Version 1. Because the controller is internally cooled, cabinet airflow remains easier to manage and external cooling capacity can be reserved for nearby devices.

Communication Interface
SERCOS III master (cross communication)
Control Section Design Type
ADVANCED
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
18 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
CANopen
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'ADVANCED' (A)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
  • HCS011EW0018A03ACCECCNS4NNFW
  • HCS01 1E W0018 A 03 A CC EC CN S4 NN FW
  • hcs01.1e-w0013_a-02-b-et-ec-nn-nn-nn-fw
  • HCS1.1E-W0018-A-03-A-CC-EC-CN-S4-NN-FW

Frequently Asked Questions about HCS01.1E-W0018-A-03-A-CC-EC-CN-S4-NN-FW:

Q: What communication interface does the HCS01.1E-W0018-A-03-A-CC-EC-CN-S4-NN-FW support?

A: The HCS01.1E-W0018-A-03-A-CC-EC-CN-S4-NN-FW supports SERCOS III master for cross communication.

Q: How is the HCS01.1E-W0018-A-03-A-CC-EC-CN-S4-NN-FW cooled?

A: This model operates with an integrated blower for internal air cooling.

Q: What is the device peak current for the HCS01.1E-W0018-A-03-A-CC-EC-CN-S4-NN-FW?

A: The device is rated for a peak current of 18 A.

Q: What mains voltage range is required for the HCS01.1E-W0018-A-03-A-CC-EC-CN-S4-NN-FW?

A: It is designed to operate on a 3-phase AC mains voltage range of 200 to 500 V ±10%.

Q: What types of encoder interfaces are available on the HCS01.1E-W0018-A-03-A-CC-EC-CN-S4-NN-FW?

A: The controller offers encoder connection via IndraDyn Hiperface and EnDat 2.1/2.2 interfaces.


Internal Product Review

  • ‘‘The HCS01.1E-W0018-A-03-A-CC-EC-CN-S4-NN-FW is an HCS drive controller rated for 18 A peak current. SERCOS III master cross communication and CANopen support make the controller especially well suited for coordinated automation architectures. Internal air cooling through an integrated blower and IP20 protection support dependable cabinet-level performance.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo