4.95 based on 202 reviews

🙶 First-time customer with Wake Industrial. The ordering process was completely seamless. The part that we o... 🙷

HCS01.1E-W0018-A-03-A-CC-EC-CN-L4-NN-FW Bosch Rexroth Indramat

MPN: R911347577

No Tariffs On US Orders
  • Rated 4.6 (50 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0018-A-03-A-CC-EC-CN-L4-NN-FW belongs to the HCS IndraDrive Controllers series and is an HCS drive controller type. It supports a SERCOS III master cross communication interface and CANopen, and includes encoder support for IndraDyn Hiperface and EnDat 2.1/2.2. This controller has a peak current of 18 Amps, uses air cooling through an integrated blower, and offers STO and SBC safety interfaces.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0018-A-03-A-CC-EC-CN-L4-NN-FW drive controller is manufactured by Bosch Rexroth Indramat as part of the HCS IndraDrive Controllers series. It converts three-phase mains power into regulated DC and PWM outputs for servo motors, providing closed-loop speed and torque control commanded by host automation systems. The compact HCS01 line format supports consistent cabinet layouts and simplifies placement in multi-axis assemblies. Typical applications include packaging stations and small material-handling axes where limited panel space and standardized mounting rails are important.

This controller accepts three-phase input voltages of 3 x AC 200 to 500 V ±10%, allowing it to operate across a broad industrial supply range. The integrated inverter stage can deliver a device peak current of 18 A, giving connected motors short-term headroom during acceleration and regenerative events. Heat is expelled by internal air cooling through an onboard blower, so no external fan assembly is required. The IP20 enclosure rating makes the unit touch-safe inside a control cabinet, but it is not intended for direct exposure to dust or liquids. Real-time motion data travels over the SERCOS III master interface with cross communication, supporting deterministic synchronization among multiple drives.

A separate bus channel offers CANopen access for diagnostics or connection to legacy controllers, and the universal feedback port reads Encoder IndraDyn Hiperface/EnDat 2.1/2.2 signals for closed-loop position control. The installed control section is the ADVANCED type, which supports expanded drive functions. Integrated STO and SBC circuits simplify machine safety functions by enabling drive-level torque shutdown and brake control. This arrangement supports motion data exchange, feedback handling, and brake control within the same controller.

Communication Interface
SERCOS III master (cross communication)
Control Section Design Type
ADVANCED
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
18 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
CANopen
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'ADVANCED' (A)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Safety Interface
STO (Safe Torque Off) and SBC (Safe Brake Control)
  • HCS011EW0018A03ACCECCNL4NNFW
  • HCS01 1E W0018 A 03 A CC EC CN L4 NN FW
  • hcs01.1e-w0013-a-02-e-s3-ec-nn-nn-aa-fw
  • HCS1.1E-W0018-A-03-A-CC-EC-CN-L4-NN-FW

Frequently Asked Questions about HCS01.1E-W0018-A-03-A-CC-EC-CN-L4-NN-FW:

Q: What is the peak current rating for the HCS01.1E-W0018-A-03-A-CC-EC-CN-L4-NN-FW controller?

A: The HCS01.1E-W0018-A-03-A-CC-EC-CN-L4-NN-FW features a device peak current of 18 A, enabling strong and responsive drive performance.

Q: Which communication interface is provided on the HCS01.1E-W0018-A-03-A-CC-EC-CN-L4-NN-FW?

A: This model uses SERCOS III master (cross communication) as its main communication interface.

Q: What cooling method is utilized by the HCS01.1E-W0018-A-03-A-CC-EC-CN-L4-NN-FW?

A: Cooling is achieved via an internal air method using an integrated blower in this controller.

Q: What safety features are integrated into the HCS01.1E-W0018-A-03-A-CC-EC-CN-L4-NN-FW drive controller?

A: The primary safety interface includes both STO (Safe Torque Off) and SBC (Safe Brake Control) functions.

Q: What mains voltage range is supported by the HCS01.1E-W0018-A-03-A-CC-EC-CN-L4-NN-FW?

A: The HCS01.1E-W0018-A-03-A-CC-EC-CN-L4-NN-FW supports a mains voltage range of 3 x AC 200 to 500 V, with a tolerance of ±10%.


Internal Product Review

  • ‘‘The HCS01.1E-W0018-A-03-A-CC-EC-CN-L4-NN-FW is an HCS drive controller with an ADVANCED control section and internal air cooling through an integrated blower. SERCOS III master cross communication and CANopen support give the controller excellent network flexibility for coordinated motion systems. STO and SBC safety functions make the controller a strong choice for safety-focused automation.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo