HCS01.1E-W0018-A-03-A-CC-EC-CN-L3-NN-FW Bosch Rexroth Indramat
MPN: R911345333
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat HCS01.1E-W0018-A-03-A-CC-EC-CN-L3-NN-FW is part of the HCS IndraDrive Controllers series. This advanced drive controller has a device peak current of 18 Amps and operates with a mains voltage of 3 x AC 200 to 500 Volts. It features a SERCOS III master communication interface with cross communication, and cooling is provided internally through an integrated blower.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The HCS01.1E-W0018-A-03-A-CC-EC-CN-L3-NN-FW is a drive controller produced by Bosch Rexroth Indramat for the HCS IndraDrive Controllers series. It serves as the power and control interface between the plant mains and servo or synchronous motors, executing velocity, position, and torque commands inside automated production equipment. By integrating safety, feedback processing, and network communication into a single chassis, the controller streamlines control cabinet design for material-handling, packaging, and light-assembly systems.
Electrical capability matches factory grids from 3 × AC 200…500 V ±10 %, letting the same hardware operate on multiple supply classes. For acceleration peaks or process upsets, the device can source a maximum of 18 A to the motor windings without exceeding thermal thresholds. Coordinated motion data is exchanged over a SERCOS III master channel that also permits cross-communication among drives to maintain sub-millisecond synchronization. The housing carries an IP20 rating, so it requires installation inside a closed cabinet to prevent accidental contact. Machine-level functional safety is supported through STO, which disables torque-producing outputs while keeping diagnostics active, allowing quick recovery after a safe stop.
This controller is supplied with an ADVANCED control section that hosts parameter memory, internal motion logic, and user-selectable technology functions. Thermal management relies on internal air cooling driven by an integrated blower, eliminating external cooling ducts. Encoder feedback connects to Interface 1, which supports IndraDyn Hiperface/EnDat 2.1/2.2 protocols, while distributed I/O or operator panels can share data over Interface 2, CANopen. Line code HCS01 and design version 1 indicate the mounting geometry, and the shared power-supply concept lets adjacent drives exchange regenerated energy through a common DC bus.
Frequently Asked Questions about HCS01.1E-W0018-A-03-A-CC-EC-CN-L3-NN-FW:
Q: What communication interface does the HCS01.1E-W0018-A-03-A-CC-EC-CN-L3-NN-FW controller use?
A: The HCS01.1E-W0018-A-03-A-CC-EC-CN-L3-NN-FW supports SERCOS III master communication with cross communication capability.
Q: What is the device peak current rating for the HCS01.1E-W0018-A-03-A-CC-EC-CN-L3-NN-FW?
A: This drive controller operates with a peak current of 18 A, enabling support for motors with moderate current requirements.
Q: How is the HCS01.1E-W0018-A-03-A-CC-EC-CN-L3-NN-FW cooled?
A: Internal air cooling is used via an integrated blower for maintaining the device’s operating temperature.
Q: What level of ingress protection does the HCS01.1E-W0018-A-03-A-CC-EC-CN-L3-NN-FW provide?
A: This drive controller provides an IP20 rating, which means it offers basic protection against touch by fingers and objects greater than 12 mm but is not water-resistant.
Q: What mains voltage range does the HCS01.1E-W0018-A-03-A-CC-EC-CN-L3-NN-FW support?
A: The mains voltage accepted by this model is 3 x AC 200...500 V with a ±10% tolerance.