HCS01.1E-W0018-A-02-E-S3-EC-NN-L4-NN-FW Bosch Rexroth Indramat
MPN: R911332690
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat HCS01.1E-W0018-A-02-E-S3-EC-NN-L4-NN-FW is an HCS Drive Controller from the HCS IndraDrive Controllers series. It features a SERCOS III communication interface, a STO and SBC safety interface, and supports a peak device current of 18 Amps. The controller uses air cooling with an integrated blower and is rated for 3 x AC 110 to 230 Volt mains voltage.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The HCS01.1E-W0018-A-02-E-S3-EC-NN-L4-NN-FW is a drive controller produced by Bosch Rexroth Indramat within the HCS IndraDrive Controllers series. As an axis inverter, it provides closed-loop control for synchronous and induction motors used in packaging, printing, and material-handling systems that require coordinated motion and stable torque regulation. The device integrates into modular drive racks and converts mains power into controlled voltage and current for connected servomotors. This arrangement allows the drive to support precise speed and position control in compact automation installations.
Communication with higher-level PLCs is handled through SERCOS III, which supports deterministic data exchange between the controller and the machine network. It uses the ECONOMY control section, which suits standard positioning tasks without unnecessary added functions. Heat is removed by internal air cooling from an integrated blower, so no external heat sink is required. The power stage accepts a three-phase supply of 3 x AC 110…230 V ±10% and can deliver up to 18 A of peak current during acceleration. The IP20 housing requires installation inside a cabinet, and the unit can operate as a rectifier or as a follower on a common DC bus.
Feedback and position control are handled through the native Encoder IndraDyn Hiperface/EnDat 2.1/2.2 channel on Interface 1, which supports direct motor feedback without an added feedback module. Interface 2 is left blank, which reduces wiring when a second encoder connection is not needed. Functional safety is integrated through STO, which removes torque-producing energy from the motor, and through SBC, which controls an external holding brake. These features allow the drive to support safe stopping functions within the axis control system while keeping the hardware layout compact.
Frequently Asked Questions about HCS01.1E-W0018-A-02-E-S3-EC-NN-L4-NN-FW:
Q: What type of communication interface is available on the HCS01.1E-W0018-A-02-E-S3-EC-NN-L4-NN-FW?
A: This drive controller uses the SERCOS III interface for its communication needs.
Q: How is the HCS01.1E-W0018-A-02-E-S3-EC-NN-L4-NN-FW cooled during operation?
A: The HCS01.1E-W0018-A-02-E-S3-EC-NN-L4-NN-FW utilizes an internal blower for air cooling.
Q: What device peak current does the HCS01.1E-W0018-A-02-E-S3-EC-NN-L4-NN-FW support?
A: The peak current this controller can deliver is 18 A.
Q: Which safety interface options are included with the HCS01.1E-W0018-A-02-E-S3-EC-NN-L4-NN-FW?
A: This model provides an STO (Safe Torque Off) and SBC (Safe Brake Control) safety interface.
Q: What is the supported mains voltage for the HCS01.1E-W0018-A-02-E-S3-EC-NN-L4-NN-FW drive controller?
A: The mains voltage supported is 3 x AC 110...230 V ±10%.