4.95 based on 202 reviews

🙶 Great response and customer service. Back-order item was shipped sooner than expected as well. 🙷

HCS01.1E-W0018-A-02-B-ET-EC-PB-S4-NN-FW Bosch Rexroth Indramat

MPN: R911345827

No Tariffs On US Orders
  • Rated 4.5 (36 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0018-A-02-B-ET-EC-PB-S4-NN-FW is a drive controller from the HCS IndraDrive Controllers series. This controller features a MultiEthernet communication interface, an integrated blower for air cooling, and a device peak current of 18 Amps. It operates with AC mains voltage from 110 to 230 volts and includes encoder connections for IndraDyn Hiperface, EnDat 2.1/2.2, and PROFIBUS interfaces.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0018-A-02-B-ET-EC-PB-S4-NN-FW is a drive controller from Bosch Rexroth Indramat in the HCS IndraDrive Controllers series. It serves as the axis regulator for synchronous or induction motors inside automated machinery, coordinating torque, speed, and position loops. Integrated power electronics, a modular control section, and multiple fieldbus ports allow the unit to exchange commands and diagnostic data with higher-level PLCs while maintaining compact panel dimensions. This layout keeps motion control, power conversion, and communication in one cabinet-mounted device. It is well suited for automation axes that need precise response and direct network integration.

This version accepts a mains supply of 3 x AC 110...230 V ±10% and can deliver a device peak current of 18 A, giving the axis short acceleration bursts without overloading the frame. Thermal energy is removed by internal air cooling through an integrated blower, so no external heat sink is required. The protection rating is IP20, indicating finger-safe live parts when the unit is mounted inside a cabinet. On the network side, a MultiEthernet interface supports EtherNet/IP, PROFINET, and Sercos over Ethernet without extra option cards. The control section is supplied in the BASIC configuration, which supports standard motion functions and parameter storage for general-purpose applications.

For feedback and field integration, the controller provides a dedicated encoder socket that handles IndraDyn Hiperface and EnDat 2.1/2.2 encoder signals, enabling absolute position capture without external converters. A separate port implements PROFIBUS, allowing legacy PLC architectures to exchange diagnostics alongside the real-time Ethernet channel. The power module is classified for infeeding and fed operation, so it can return braking energy to the DC link or draw energy from a companion supply in multi-axis systems. This arrangement supports mixed-control environments where newer networks and established fieldbus links operate on the same machine. Design version 1 and the HCS01 line geometry keep the housing aligned with common panel spacing in this platform.

Communication Interface
MultiEthernet
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
18 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
PROFIBUS
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 110...230 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
  • HCS011EW0018A02BETECPBS4NNFW
  • HCS01 1E W0018 A 02 B ET EC PB S4 NN FW
  • hcs01.1e-w0013-a-02-b-et-ec-pb-nn-aa-fw
  • HCS1.1E-W0018-A-02-B-ET-EC-PB-S4-NN-FW

Frequently Asked Questions about HCS01.1E-W0018-A-02-B-ET-EC-PB-S4-NN-FW:

Q: What communication interface is available on the HCS01.1E-W0018-A-02-B-ET-EC-PB-S4-NN-FW controller?

A: The HCS01.1E-W0018-A-02-B-ET-EC-PB-S4-NN-FW supports MultiEthernet communication, allowing versatile network integration.

Q: What is the device peak current for the HCS01.1E-W0018-A-02-B-ET-EC-PB-S4-NN-FW?

A: The peak current rating for this drive controller is 18 A, providing robust current capacity for connected motors.

Q: What is the IP rating of the HCS01.1E-W0018-A-02-B-ET-EC-PB-S4-NN-FW controller?

A: This model has an IP20 rating, offering basic protection against solid objects but not against water.

Q: What cooling method does the HCS01.1E-W0018-A-02-B-ET-EC-PB-S4-NN-FW utilize?

A: The controller uses internal air cooling provided by an integrated blower for thermal management.

Q: What mains voltage range does the HCS01.1E-W0018-A-02-B-ET-EC-PB-S4-NN-FW support?

A: It is designed for operation on a 3 x AC 110...230 V supply with a ±10% voltage tolerance.


Internal Product Review

  • ‘‘The HCS01.1E-W0018-A-02-B-ET-EC-PB-S4-NN-FW is an HCS drive controller with MultiEthernet communication and 18 A peak current capability. Internal air cooling and IP20 protection support clean cabinet integration and dependable operation. A strong choice for efficient industrial motion control.’’