4.95 based on 202 reviews

🙶 Easy to navigate website and quick responses from support. Additionally, pretty fast shipping. Our mainte... 🙷

HCS01.1E-W0018-A-02-B-ET-EC-EM-NN-NN-FW Bosch Rexroth Indramat

MPN: R911335954

No Tariffs On US Orders
  • Rated 4.6 (39 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0018-A-02-B-ET-EC-EM-NN-NN-FW is part of the HCS IndraDrive Controllers series and serves as a drive controller with a peak current of 18 Amps. It features MultiEthernet communication and operates at a mains voltage of 3 x AC 110 to 230 Volts. This model uses internal air cooling with an integrated blower and is rated at IP20.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0018-A-02-B-ET-EC-EM-NN-NN-FW belongs to the HCS IndraDrive Controllers series. As an HCS01 line drive controller, it converts supply power and processes encoder data so connected servo or induction motors can follow motion commands from the plant PLC. Installed in a switchgear cabinet, the unit coordinates acceleration, deceleration, and positioning sequences in multi-axis industrial automation. It supports coordinated motion where several cabinet-mounted axes must respond through the same control architecture.

The controller links to supervisory networks through MultiEthernet, allowing selection of PROFINET, EtherNet/IP, or EtherCAT without hardware changes. It accepts a supply of 3 x AC 110…230 V ±10%, making it suitable for a wide range of low-voltage mains systems. During dynamic events, the power stage can source up to 18 A of peak current to the motor. Heat is removed by internal air cooling that uses an integrated blower, so no external ducting is required. The housing has an IP20 rating, and precise position data enter through the first feedback port that supports Encoder IndraDyn Hiperface/EnDat 2.1/2.2 for high-resolution synchronous operation. This network flexibility allows the same hardware platform to fit different plant communication standards.

The second feedback socket can output encoder emulation signals for legacy motion controllers that expect incremental channels. This allows older control systems to receive position signals from the drive without changing the basic feedback concept. Power exchange with the DC bus is handled through infeeding and fed operation, which allows energy sharing among multiple axes. The control section is BASIC, and the unit is design version 1. No integrated safety interface is included, so external safety components must be provided where needed.

Communication Interface
MultiEthernet
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
18 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Encoder emulation
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 110...230 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Safety Interface
Not equipped
  • HCS011EW0018A02BETECEMNNNNFW
  • HCS01 1E W0018 A 02 B ET EC EM NN NN FW
  • hcs01.1e-w0013-a-02-b-et-ec-ep-s5-nn-fw
  • HCS1.1E-W0018-A-02-B-ET-EC-EM-NN-NN-FW

Frequently Asked Questions about HCS01.1E-W0018-A-02-B-ET-EC-EM-NN-NN-FW:

Q: What communication interface does the HCS01.1E-W0018-A-02-B-ET-EC-EM-NN-NN-FW controller support?

A: The HCS01.1E-W0018-A-02-B-ET-EC-EM-NN-NN-FW controller provides MultiEthernet communication interface for versatile connectivity options.

Q: How is the HCS01.1E-W0018-A-02-B-ET-EC-EM-NN-NN-FW controller cooled?

A: The cooling for this drive controller is handled internally using an integrated blower with air cooling.

Q: What is the peak current rating of the HCS01.1E-W0018-A-02-B-ET-EC-EM-NN-NN-FW controller?

A: The peak current output for this drive controller is 18 A.

Q: What is the mains voltage range for the HCS01.1E-W0018-A-02-B-ET-EC-EM-NN-NN-FW controller?

A: This model is rated for a mains voltage of 3 x AC 110 to 230 V with a tolerance of ±10%.

Q: What IP rating does the HCS01.1E-W0018-A-02-B-ET-EC-EM-NN-NN-FW controller have?

A: The controller has an IP20 protection rating, providing protection against solid objects larger than 12 mm but not against liquids.


Internal Product Review

  • ‘‘The HCS01.1E-W0018-A-02-B-ET-EC-EM-NN-NN-FW is an HCS Drive Controller with MultiEthernet communication that supports flexible network integration. Internal air cooling and 18 A peak current give the controller strong thermal management and responsive drive performance. BASIC control architecture with 3 x AC 110...230 V input makes the controller a practical choice for efficient IndraDrive installations.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo