HCS01.1E-W0018-A-02-B-ET-EC-EC-S4-NN-FW Bosch Rexroth Indramat

MPN: R911342166

No Tariffs On US Orders
  • Rated 4.4 (25 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
In-Stock, Ships 3-5 Days

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0018-A-02-B-ET-EC-EC-S4-NN-FW is part of the HCS IndraDrive Controllers series and is designed as an HCS drive controller with a device peak current of 18 Amps. It features MultiEthernet communication, has internal air cooling through an integrated blower, and operates with a mains voltage of 3 x AC 110 to 230 Volts plus or minus 10 percent. The controller has an IP20 protection rating and supports encoder interfaces such as IndraDyn Hiperface and EnDat 2.1 or 2.2.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0018-A-02-B-ET-EC-EC-S4-NN-FW is a drive controller produced by Bosch Rexroth Indramat within the HCS IndraDrive Controllers series. It combines a power stage and control electronics to regulate servo and induction motors used in industrial handling, packaging, and machining cells. By converting the incoming three-phase supply into controlled output voltage and current, the unit executes speed, torque, and position commands issued by higher-level PLCs. This arrangement allows one compact controller to manage motor response while supporting repeatable motion in automated equipment.

The control section is classified as BASIC, so parameter sets and diagnostics are handled through a streamlined feature set suited for standard motion tasks. Network data exchange occurs over the integrated MultiEthernet port, allowing the device to join EtherNet/IP, PROFINET, or EtherCAT topologies without extra option cards. Its input accepts a mains window of 3 x AC 110…230 V ±10%, making the controller suitable for low-voltage installations on both 50 Hz and 60 Hz grids. During dynamic acceleration or deceleration, the inverter can deliver a device peak current of 18 A, which is the maximum short-term motor current the drive can supply before protective limiting begins. The housing carries an IP20 rating, so it must be mounted inside a control cabinet where solid objects larger than 12.5 mm are excluded and convection airflow is available.

The unit is Design Version 1, indicating the first mechanical and electrical release of this power section. Heat is removed by an internal blower, eliminating the need for external ducting and keeping sensitive components below their thermal limits at full load. Two feedback sockets support Encoder IndraDyn Hiperface/EnDat 2.1/2.2 protocols, enabling absolute position reporting from synchronous motors without additional converters. Power sharing can be arranged because the unit is configured for Infeeding/Feeded operation, meaning it may operate as a common DC bus supply or as a follower that draws energy from another infeed module.

Communication Interface
MultiEthernet
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
18 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 110...230 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
  • HCS011EW0018A02BETECECS4NNFW
  • HCS01 1E W0018 A 02 B ET EC EC S4 NN FW
  • hcs01.1e-w0013-a-02-b-et-ec-ep-l4-nn-fw
  • HCS1.1E-W0018-A-02-B-ET-EC-EC-S4-NN-FW

Frequently Asked Questions about HCS01.1E-W0018-A-02-B-ET-EC-EC-S4-NN-FW:

Q: What communication interface is available on the HCS01.1E-W0018-A-02-B-ET-EC-EC-S4-NN-FW?

A: This controller provides MultiEthernet communication for networking and system integration.

Q: What is the peak current rating of the HCS01.1E-W0018-A-02-B-ET-EC-EC-S4-NN-FW?

A: The HCS01.1E-W0018-A-02-B-ET-EC-EC-S4-NN-FW supports a device peak current of 18 A.

Q: How is the HCS01.1E-W0018-A-02-B-ET-EC-EC-S4-NN-FW cooled during operation?

A: This drive controller uses an internal air cooling method with an integrated blower.

Q: What is the IP rating of the HCS01.1E-W0018-A-02-B-ET-EC-EC-S4-NN-FW drive controller?

A: The controller features an IP20 protection rating, suitable for environments without direct exposure to dust and moisture.

Q: What mains voltage range does the HCS01.1E-W0018-A-02-B-ET-EC-EC-S4-NN-FW support?

A: It can operate on a three-phase mains voltage from 110 to 230 V AC ±10%.


Internal Product Review

  • ‘‘The HCS01.1E-W0018-A-02-B-ET-EC-EC-S4-NN-FW is an HCS drive controller configured with a BASIC control section. MultiEthernet communication and dual encoder support for IndraDyn Hiperface/EnDat 2.1/2.2 enable efficient integration and accurate feedback processing. Internal blower cooling and an 18 A peak current rating make the unit a strong choice for demanding motion control applications.’’