4.95 based on 202 reviews

🙶 Great service, they have the parts i needed in stock. 🙷

HCS01.1E-W0018-A-02-B-ET-EC-EC-NN-NN-FW Bosch Rexroth Indramat

MPN: R911332181

No Tariffs On US Orders
  • Rated 4.5 (58 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
In-Stock, Ships 3-5 Days

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0018-A-02-B-ET-EC-EC-NN-NN-FW is part of the HCS IndraDrive Controllers series. This HCS drive controller features a MultiEthernet communication interface and internal air cooling through an integrated blower. It has a device peak current of 18 Amps and supports encoder interfaces such as IndraDyn Hiperface and EnDat 2.1/2.2.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0018-A-02-B-ET-EC-EC-NN-NN-FW is a drive controller built by Bosch Rexroth Indramat and included in the HCS IndraDrive Controllers series. Its platform follows the HCS01 line, so it shares mounting dimensions with companion modules. It regulates servo and induction motors in multi-axis automation cells by converting line power into controlled output and by exchanging motion data with higher-level PLCs. The unit offers scalable performance for packaging, material handling, and general machinery where compact, panel-mounted control hardware is required.

The controller accepts a three-phase mains supply of 3 x AC 110 to 230 V ±10%, so it can wire directly to plant power without an external transformer. An internal IGBT stage delivers a peak current of 18 A for brief acceleration demands. Motion and diagnostic data travel over the MultiEthernet interface, which can be set to EtherNet/IP, PROFINET, or EtherCAT. The control section is the BASIC variant, providing standard axis functions and omitting optional add-ons. An IP20 housing requires cabinet mounting while guarding against contact with live parts. The supply section is set for common DC-bus use, allowing multiple drives to share energy.

Both feedback sockets are wired for IndraDyn Hiperface/EnDat 2.1/2.2 encoders, allowing absolute position data to be read without additional adapter boards. Cooling uses internal air cooling through an integrated blower, so cabinet airflow requirements stay minimal while the drive removes its own heat. Design Version 1 identifies the first release of this unit. The integrated power module supports infeeding and fed operation, allowing the unit to act as a DC-bus supply or as a consumer on a shared bus. No safety interface is included, and the control section is factory matched so no additional options are specified.

Communication Interface
MultiEthernet
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
18 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 110...230 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Safety Interface
Not equipped
  • HCS011EW0018A02BETECECNNNNFW
  • HCS01 1E W0018 A 02 B ET EC EC NN NN FW
  • hcs01.1e-w0013-a-02-b-et-ec-ep-l4-nn-aw
  • HCS1.1E-W0018-A-02-B-ET-EC-EC-NN-NN-FW

Frequently Asked Questions about HCS01.1E-W0018-A-02-B-ET-EC-EC-NN-NN-FW:

Q: What type of communication interface does the HCS01.1E-W0018-A-02-B-ET-EC-EC-NN-NN-FW drive controller use?

A: The HCS01.1E-W0018-A-02-B-ET-EC-EC-NN-NN-FW supports MultiEthernet communication for flexible network integration.

Q: What is the mains voltage requirement for the HCS01.1E-W0018-A-02-B-ET-EC-EC-NN-NN-FW?

A: This drive controller operates with a mains voltage of 3 x AC 110 to 230 V ±10%, making it suitable for a range of global power standards.

Q: What is the peak current supported by the HCS01.1E-W0018-A-02-B-ET-EC-EC-NN-NN-FW drive controller?

A: The HCS01.1E-W0018-A-02-B-ET-EC-EC-NN-NN-FW has a device peak current rating of 18 A for high-demand operations.

Q: How is the HCS01.1E-W0018-A-02-B-ET-EC-EC-NN-NN-FW cooled?

A: Cooling is handled by internal air circulation through an integrated blower in this model.

Q: What is the IP rating of the HCS01.1E-W0018-A-02-B-ET-EC-EC-NN-NN-FW drive controller?

A: This controller features IP20 protection, offering basic dust ingress protection for indoor environments.


Internal Product Review

  • ‘‘The HCS01.1E-W0018-A-02-B-ET-EC-EC-NN-NN-FW is a Bosch Rexroth Indramat HCS drive controller with a BASIC control section and MultiEthernet communication. Internal blower cooling and a 3 x AC 110...230 V mains range support stable cabinet integration and flexible deployment. IP20 protection and 18 A peak current make the controller a strong choice for efficient IndraDrive motion applications.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo