4.95 based on 202 reviews

🙶 Wake was very helpful in getting us a servo motor and drive for our tube mill line. This was the first tim... 🙷

HCS01.1E-W0018-A-02-B-ET-EC-EC-NN-NN-AW Bosch Rexroth Indramat

MPN: R911395337

Ask for Availability
Current Response Time 6 min 0 sec

The Bosch Rexroth Indramat HCS01.1E-W0018-A-02-B-ET-EC-EC-NN-NN-AW is a drive controller from the HCS IndraDrive Controllers series. This controller features a MultiEthernet communication interface and supports encoder interfaces such as IndraDyn Hiperface and EnDat 2.1/2.2. It operates with an internal air cooling method through an integrated blower, has a peak current of 18 Amps, and is rated at IP20 for protection.

No Hidden Fees Rush or Credit Card
No Tariffs On US Orders

Internal Product Review

The HCS01.1E-W0018-A-02-B-ET-EC-EC-NN-NN-AW is an HCS drive controller with MultiEthernet communication. Internal blower cooling and an 18 A peak current give this unit a capable, well-balanced performance profile for demanding motion applications. IP20 protection and a 3 x AC 110...230 V input range make this controller a strong choice for flexible industrial integration.

Sell Part Have a part to sell?
Warranty Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

Bosch Rexroth Indramat manufactures the HCS01.1E-W0018-A-02-B-ET-EC-EC-NN-NN-AW as part of the HCS IndraDrive Controllers series. This drive controller combines a power section with a detachable control section to regulate servo and induction motors in compact machinery, where space-saving installation and direct motor control are important. Within an automation cell, the unit converts incoming three-phase mains power into a controlled output and coordinates motion through its integrated logic, allowing precise speed and torque commands from higher-level PLCs during indexing, conveying, and other repeatable machine movements.

The power section accepts a supply of 3 x AC 110...230 V ±10% and uses an internal DC bus sized to deliver a device peak current of 18 A for short-term load surges. Heat generated by the switching devices is removed by internal air cooling through an integrated blower, so no additional ducting is required inside the cabinet. The enclosure is rated IP20, which provides finger-safe protection for indoor electrical panels and suits installation inside a protected cabinet rather than on an exposed machine surface. For network connectivity, the controller includes a MultiEthernet interface that supports several industrial Ethernet protocols, allowing the same hardware to integrate with different plant standards.

The detachable control section installed on this model is the BASIC variant, which suits standard positioning tasks without adding unnecessary complexity. Both encoder ports use the IndraDyn Hiperface/EnDat 2.1/2.2 encoder interface, enabling single-turn or multi-turn feedback from Rexroth and third-party motors without additional adapter cards. Power for the DC bus is handled in an infeed and fed configuration, so several drives can share a common supply and regeneration path. The controller belongs to the HCS01 line, and this unit is design version 1, so its mechanical dimensions and connector locations match the first release across the series. No dedicated safety interface is included, so external safety relays or logic must be used when required.

Communication Interface
MultiEthernet
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
18 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 110...230 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Safety Interface
Not equipped

Frequently Asked Questions about HCS01.1E-W0018-A-02-B-ET-EC-EC-NN-NN-AW:

Q: What kind of communication interface does the HCS01.1E-W0018-A-02-B-ET-EC-EC-NN-NN-AW drive controller use?

A: This unit comes equipped with a MultiEthernet communication interface for diverse network integration.

Q: What is the peak current output of the HCS01.1E-W0018-A-02-B-ET-EC-EC-NN-NN-AW drive controller?

A: The HCS01.1E-W0018-A-02-B-ET-EC-EC-NN-NN-AW supports a device peak current of 18 A.

Q: How is the HCS01.1E-W0018-A-02-B-ET-EC-EC-NN-NN-AW drive controller cooled?

A: Cooling is achieved via an internal air method using an integrated blower on this model.

Q: What is the IP rating of the HCS01.1E-W0018-A-02-B-ET-EC-EC-NN-NN-AW drive controller?

A: The device is rated at IP20, offering basic protection against solid objects but not against liquids.

Q: What types of encoder interfaces are found on the HCS01.1E-W0018-A-02-B-ET-EC-EC-NN-NN-AW controller?

A: Two encoder interfaces are available, both compatible with IndraDyn Hiperface and EnDat 2.1/2.2 standards.

  • HCS011EW0018A02BETECECNNNNAW
  • HCS01 1E W0018 A 02 B ET EC EC NN NN AW
  • hcs01.1e-w0013-a-02-b-et-ec-ep-l3-nn-fw
  • HCS1.1E-W0018-A-02-B-ET-EC-EC-NN-NN-AW
Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo