4.95 based on 202 reviews

🙶 Great response and customer service. Back-order item was shipped sooner than expected as well. 🙷

HCS01.1E-W0018-A-02-B-ET-EC-CN-NN-NN-FW Bosch Rexroth Indramat

MPN: R911339364

No Tariffs On US Orders
  • Rated 4.4 (73 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Current response time:
3 Minutes 4 Seconds

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0018-A-02-B-ET-EC-CN-NN-NN-FW is an HCS Drive Controller from the HCS IndraDrive Controllers series. It features a MultiEthernet communication interface, supports encoder interfaces such as IndraDyn Hiperface and EnDat 2.1/2.2, and is designed for use with CANopen networks. This controller has a device peak current of 18 Amps, uses air cooling through an integrated blower, and is rated for mains voltages of 3 x AC 110 to 230 Volts.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0018-A-02-B-ET-EC-CN-NN-NN-FW drive controller is manufactured by Bosch Rexroth Indramat as part of the HCS IndraDrive Controllers series in the HCS01 line. It functions as a compact power and motion processor that modulates current for servo and induction motors in automated production cells, conveyors, and handling stations. By interfacing with feedback devices and plant networks, the unit converts high-level commands into precisely timed motor phase currents, enabling coordinated positioning, speed regulation, and torque control throughout an industrial automation system. Its compact format suits cabinet installations where drive control, motor feedback handling, and network communication must be combined in one module. Because current control and motion processing are handled inside the controller, the connected motor can respond quickly to changing load and command conditions.

The controller operates from a three-phase supply of 3 × AC 110–230 V ±10%, allowing installation on both low-voltage and standard factory mains. During acceleration or dynamic braking, it can supply a peak current of 18 A, so the connected axis can overcome inertia without saturating the power stage. Heat generated by the IGBT bridge is removed by internal air cooling, using an integrated blower that eliminates the need for external ducting. The housing has an IP20 protection rating, which provides finger-safe access while reserving the unit for enclosed cabinets. For control traffic, the device offers MultiEthernet, which combines several Ethernet-based protocols in a single port and helps simplify wiring. This arrangement supports compact drive layouts that do not have room for separate cooling accessories.

The control section is identified as BASIC, and the paired electronics pack matches the power section supplied with the unit. Motion feedback is accepted through the Encoder IndraDyn Hiperface/EnDat 2.1/2.2 interface, while auxiliary machine data can be exchanged over CANopen. The drive uses Infeeding / Feeded operation, enabling shared DC-bus use and power regeneration between compatible axes. This combination supports coordinated communication between the motor feedback channel, the fieldbus connection, and the internal power section during normal machine operation. It can therefore support systems that exchange position data and machine-level commands at the same time.

Communication Interface
MultiEthernet
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
18 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
CANopen
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 110...230 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Safety Interface
Not equipped
  • HCS011EW0018A02BETECCNNNNNFW
  • HCS01 1E W0018 A 02 B ET EC CN NN NN FW
  • hcs01.1e-w0013-a-02-b-et-ec-em-l4-nn-fw
  • HCS1.1E-W0018-A-02-B-ET-EC-CN-NN-NN-FW

Frequently Asked Questions about HCS01.1E-W0018-A-02-B-ET-EC-CN-NN-NN-FW:

Q: What communication interface is available on the HCS01.1E-W0018-A-02-B-ET-EC-CN-NN-NN-FW controller?

A: The HCS01.1E-W0018-A-02-B-ET-EC-CN-NN-NN-FW supports MultiEthernet for communication.

Q: How is the HCS01.1E-W0018-A-02-B-ET-EC-CN-NN-NN-FW cooled?

A: This drive controller is cooled internally using an integrated blower.

Q: What is the peak current rating of the HCS01.1E-W0018-A-02-B-ET-EC-CN-NN-NN-FW?

A: The peak current for this device is specified at 18 A.

Q: What type of encoder interface is featured on the HCS01.1E-W0018-A-02-B-ET-EC-CN-NN-NN-FW?

A: The HCS01.1E-W0018-A-02-B-ET-EC-CN-NN-NN-FW includes an encoder interface for IndraDyn Hiperface and EnDat 2.1/2.2.

Q: What mains voltage range does the HCS01.1E-W0018-A-02-B-ET-EC-CN-NN-NN-FW support?

A: This controller operates at 3-phase AC mains voltage ranging from 110 to 230 V with ±10% tolerance.


Internal Product Review

  • ‘‘The HCS01.1E-W0018-A-02-B-ET-EC-CN-NN-NN-FW is an HCS drive controller with a BASIC control section and MultiEthernet communication. Internal blower cooling and 18 A peak current support stable thermal management and responsive drive performance in demanding motion applications. CANopen on the second interface adds useful integration flexibility, making this unit a strong choice for IP20 industrial control systems.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo