4.95 based on 202 reviews

🙶 a+ fast delivery 🙷

HCS01.1E-W0018-A-02-A-ET-EC-NN-NN-NN-FW Bosch Rexroth Indramat

MPN: R911378078

No Tariffs On US Orders
  • Rated 4.6 (56 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0018-A-02-A-ET-EC-NN-NN-NN-FW is an HCS Drive Controller from the HCS IndraDrive Controllers series. It features a MultiEthernet communication interface, an IP20 rating, and supports mains voltages from 110 to 230 volts AC. This controller has a device peak current of 18 amps and uses air cooling through an internal blower.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0018-A-02-A-ET-EC-NN-NN-NN-FW is a compact drive controller produced by Bosch Rexroth Indramat within the HCS IndraDrive Controllers series. Installed between the plant mains and the servo motor, it modulates voltage, monitors feedback, and executes motion commands for packaging lines, handling cells, and material transport modules. This role lets the unit manage both motor control and command processing for compact servo axes. Its compact construction suits cabinets where precise motion control is needed without a large drive footprint.

At the power stage, the unit can supply a device peak current of 18 A, allowing short acceleration bursts without tripping protective limits. It accepts 3 × AC 110…230 V ±10 % from standard low-voltage three-phase grids. That input range allows the controller to fit common industrial power systems without a separate transformer in many installations. Thermal management is handled by an internal air blower, so heat is carried through the housing without external heat sinks. On the control side, a MultiEthernet port supports several Ethernet-based protocols for flexible network integration. Motor feedback is processed through the Encoder IndraDyn Hiperface/EnDat 2.1/2.2 interface, enabling high-resolution position loops for synchronous or asynchronous axes. The controller does not include a second feedback channel or an integrated safety interface.

The housing has an IP20 rating, so the controller is intended for installation inside a protected cabinet rather than on an exposed machine surface. The unit is design version 1. Within the HCS01 mechanical envelope, the drive remains compact while fitting the platform used for this controller class. It uses an Infeeding / Feeded power section that handles line regeneration and DC-bus energy distribution, which removes the need for a separate supply module. No supplementary mechanical options are fitted on this version, keeping the configuration straightforward for applications that do not require added hardware features.

Communication Interface
MultiEthernet
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
18 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Not equipped
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 110...230 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Safety Interface
Not equipped
  • HCS011EW0018A02AETECNNNNNNFW
  • HCS01 1E W0018 A 02 A ET EC NN NN NN FW
  • hcs01.1e-w0013-a-02-b-et-ec-ec-nn-nn-fw
  • HCS1.1E-W0018-A-02-A-ET-EC-NN-NN-NN-FW

Frequently Asked Questions about HCS01.1E-W0018-A-02-A-ET-EC-NN-NN-NN-FW:

Q: What type of communication interface does the HCS01.1E-W0018-A-02-A-ET-EC-NN-NN-NN-FW use?

A: The HCS01.1E-W0018-A-02-A-ET-EC-NN-NN-NN-FW supports MultiEthernet communication for network connectivity.

Q: What is the peak current rating of the HCS01.1E-W0018-A-02-A-ET-EC-NN-NN-NN-FW?

A: This drive controller has a device peak current of 18 A for handling demanding loads.

Q: What cooling method does the HCS01.1E-W0018-A-02-A-ET-EC-NN-NN-NN-FW utilize?

A: Internal air cooling is provided by an integrated blower in this model.

Q: What is the IP rating of the HCS01.1E-W0018-A-02-A-ET-EC-NN-NN-NN-FW drive controller?

A: The HCS01.1E-W0018-A-02-A-ET-EC-NN-NN-NN-FW offers an IP20 protection rating.

Q: What mains voltage range does the HCS01.1E-W0018-A-02-A-ET-EC-NN-NN-NN-FW require for operation?

A: This model operates with a mains voltage supply of three-phase AC 110 to 230 V with a tolerance of ±10%.


Internal Product Review

  • ‘‘The HCS01.1E-W0018-A-02-A-ET-EC-NN-NN-NN-FW is an HCS drive controller engineered for efficient cabinet integration, with internal air cooling and an IP20 enclosure. MultiEthernet communication and encoder support for IndraDyn Hiperface/EnDat 2.1/2.2 provide strong connectivity and precise feedback compatibility. An 18 A peak current on 3 x AC 110...230 V input makes the unit a capable choice for flexible drive applications.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo