The Bosch Rexroth Indramat HCS01.1E-W0018-A-02-A-ET-EC-NN-L3-NN-FW is part of the HCS IndraDrive Controllers series and operates with a device peak current of 18 A and an IP20 rating. It features MultiEthernet communication, an encoder interface for IndraDyn Hiperface or EnDat 2.1/2.2, and uses an internal air cooling method with an integrated blower. The drive controller supports mains voltage of 3 x AC 110 to 230 V and includes an STO safety interface.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0018-A-02-A-ET-EC-NN-L3-NN-FW is a drive controller manufactured by Bosch Rexroth Indramat for the HCS IndraDrive Controllers series. It converts incoming mains power into regulated motor current so that machine axes can follow commanded speed, torque, or position references. Installed in a control cabinet, the controller works with an external control section to operate conveyors, pick-and-place units, and other material-handling equipment. Within an IndraDrive system, it serves as the power section while the control section handles command processing and network management. This arrangement supports compact cabinet layouts for general industrial motion applications.

The unit accepts a three-phase supply of 3 x AC 110...230 V ±10% and can deliver up to 18 A of peak current to the connected motor. Heat is removed by a built-in air blower, so cabinet airflow must support the cooling path without requiring an external fan. The enclosure has an IP20 rating, which protects against accidental finger contact but still requires installation inside a suitable cabinet. Because IP20 does not seal against dust or moisture, the surrounding enclosure must provide the needed protection for the application. The power stage can share a common DC bus and return braking energy to the mains during deceleration. Communication with the higher-level control runs over MultiEthernet, allowing integration with industrial Ethernet networks such as PROFINET or EtherNet/IP.

Motor feedback is connected through Interface 1, which accepts Encoder IndraDyn Hiperface/EnDat 2.1/2.2 signals for closed-loop control. This feedback compatibility supports servo motors that use those digital encoder families for position and speed data. Interface 2 is not equipped, so this version uses a single feedback input. Functional safety is provided by STO (Safe Torque Off), which disables torque production without removing mains power from the unit. The controller belongs to the HCS01 line and is intended for use with a BASIC control section.

Communication Interface
MultiEthernet
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
18 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Not equipped
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 110...230 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Safety Interface
STO (Safe Torque Off)
  • HCS011EW0018A02AETECNNL3NNFW
  • HCS01 1E W0018 A 02 A ET EC NN L3 NN FW
  • hcs01.1e-w0013-a-02-b-et-ec-ec-l4-nn-fw
  • HCS1.1E-W0018-A-02-A-ET-EC-NN-L3-NN-FW

Frequently Asked Questions about HCS01.1E-W0018-A-02-A-ET-EC-NN-L3-NN-FW:

Q: What type of communication interface does the HCS01.1E-W0018-A-02-A-ET-EC-NN-L3-NN-FW drive controller use?

A: This model features a MultiEthernet communication interface for flexible network connectivity.

Q: What is the peak current supported by the HCS01.1E-W0018-A-02-A-ET-EC-NN-L3-NN-FW controller?

A: It supports a device peak current of 18 A for high-performance drive applications.

Q: How is the HCS01.1E-W0018-A-02-A-ET-EC-NN-L3-NN-FW drive controller cooled?

A: The internal air cooling system uses an integrated blower to maintain operating temperature.

Q: What mains voltage range does the HCS01.1E-W0018-A-02-A-ET-EC-NN-L3-NN-FW support?

A: This unit operates with a mains supply voltage of 3 x AC 110 to 230 V ±10%.

Q: What safety interface is present on the HCS01.1E-W0018-A-02-A-ET-EC-NN-L3-NN-FW model?

A: It features an STO (Safe Torque Off) safety interface for enhanced operational safety.


Internal Product Review

  • ‘‘The HCS01.1E-W0018-A-02-A-ET-EC-NN-L3-NN-FW is a Bosch Rexroth Indramat HCS drive controller with MultiEthernet communication and internal air-blower cooling. The controller supports 3 x AC 110...230 V ±10% mains input and delivers 18 A peak current, which suits responsive drive applications well. IP20 protection and STO Safe Torque Off complete a well-engineered control package.’’