The Bosch Rexroth Indramat HCS01.1E-W0018-A-02-A-CC-EC-NN-S4-NN-FW is an HCS Drive Controller from the HCS IndraDrive Controllers series. It has a peak current of 18 Amps, runs on a 3-phase AC 110 to 230 Volt supply, and uses an internal air cooling method with an integrated blower. The controller features a SERCOS III master communication interface and supports encoder interfaces like IndraDyn Hiperface and EnDat 2.1/2.2.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0018-A-02-A-CC-EC-NN-S4-NN-FW is a drive controller produced by Bosch Rexroth Indramat for the HCS IndraDrive Controllers series. It functions as the axis power stage in modular motion systems, converting mains power into regulated three-phase output for servo or induction motors while exchanging real-time data with the higher-level PLC. This arrangement lets the controller coordinate velocity, torque, and position loops in automated packaging lines, material-handling cells, and general factory automation. Its role combines power conversion and closed-loop motion control within a cabinet-based drive system.

This unit communicates with neighboring drives and control hardware through a SERCOS III master with cross communication interface that supports deterministic data exchange for synchronous multi-axis motion. The control section uses the ADVANCED design, so extended motion functions and diagnostics are available without external option cards. A peak output current of 18 A covers medium-power rotary or linear motors, provided the incoming supply remains within 3 x AC 110…230 V ±10%. The housing has an IP20 rating for installation inside a closed electrical cabinet. A second feedback port is not equipped, which keeps the feedback layout focused on a single motor channel.

Thermal management uses internal air cooling through an integrated blower, and the blower moves cabinet air across the heat sink without external ducting. Feedback from connected motors enters through the IndraDyn Hiperface/EnDat 2.1/2.2 encoder interface, enabling high-resolution position control. DC bus power is exchanged through an infeeding and feeding arrangement, allowing several drives to share braking energy during operation. The controller is part of the HCS01 line, and design version 1 is used for the unit. This layout supports shared power flow in multi-axis systems without adding external cooling hardware.

Communication Interface
SERCOS III master (cross communication)
Control Section Design Type
ADVANCED
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
18 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Not equipped
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 110...230 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'ADVANCED' (A)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
  • HCS011EW0018A02ACCECNNS4NNFW
  • HCS01 1E W0018 A 02 A CC EC NN S4 NN FW
  • hcs01.1e-w0013-a-02-b-et-ec-cn-nn-nn-fw
  • HCS1.1E-W0018-A-02-A-CC-EC-NN-S4-NN-FW

Frequently Asked Questions about HCS01.1E-W0018-A-02-A-CC-EC-NN-S4-NN-FW:

Q: What is the device peak current capability of the HCS01.1E-W0018-A-02-A-CC-EC-NN-S4-NN-FW controller?

A: This model operates with a device peak current of 18 A for demanding drive applications.

Q: What cooling method is used in the HCS01.1E-W0018-A-02-A-CC-EC-NN-S4-NN-FW drive controller?

A: The HCS01.1E-W0018-A-02-A-CC-EC-NN-S4-NN-FW uses air cooling through an integrated blower for internal temperature management.

Q: Which communication interface does the HCS01.1E-W0018-A-02-A-CC-EC-NN-S4-NN-FW provide?

A: This controller supports SERCOS III master cross communication for robust network integration.

Q: What type of encoder feedback is supported by the HCS01.1E-W0018-A-02-A-CC-EC-NN-S4-NN-FW controller?

A: The main encoder interface accommodates IndraDyn Hiperface and EnDat 2.1/2.2 feedback devices.

Q: What mains voltage range does the HCS01.1E-W0018-A-02-A-CC-EC-NN-S4-NN-FW accept?

A: This unit is rated for a mains voltage input of 3 x AC 110 to 230 volts, plus or minus 10%.


Internal Product Review

  • ‘‘The HCS01.1E-W0018-A-02-A-CC-EC-NN-S4-NN-FW is an HCS Drive Controller with an ADVANCED control section and SERCOS III master cross communication. Integrated blower cooling and 18 A peak current support stable thermal behavior and confident dynamic response. IP20 protection makes the controller a dependable choice for clean cabinet installations.’’