4.95 based on 202 reviews

🙶 Easy to navigate website and quick responses from support. Additionally, pretty fast shipping. Our mainte... 🙷

HCS01.1E-W0018-A-02-A-CC-EC-ET-NN-NN-FW Bosch Rexroth Indramat

MPN: R911338058

No Tariffs On US Orders
  • Rated 4.4 (26 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0018-A-02-A-CC-EC-ET-NN-NN-FW is a drive controller from the HCS IndraDrive Controllers series. It features an ADVANCED control section, supports SERCOS III cross communication, and has a device peak current of 18 Amps. The unit operates with a 3 x AC 110 to 230 V mains voltage and uses an internal air cooling method with an integrated blower.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0018-A-02-A-CC-EC-ET-NN-NN-FW is a drive controller manufactured by Bosch Rexroth Indramat for the HCS IndraDrive Controllers series. It is used in multi-axis automation systems to regulate power delivery, speed, and position for connected servo or induction motors. The unit forms the power section of an IndraDrive system and works with a separate control section to support closed-loop motion in industrial machinery. In typical machine layouts, it converts incoming electrical energy into controlled motor current so axes can follow commanded motion profiles during indexing, conveying, and positioning tasks.

This controller supplies a peak output of 18 A, allowing short periods of higher torque during acceleration or braking. It operates from a three-phase mains range of 3 x AC 110...230 V ±10%, which supports use on low-voltage factory power systems. Command and diagnostic data are exchanged over SERCOS III, and the paired control section is identified as ADVANCED. This communication structure supports synchronized data exchange between drives on the same ring and helps coordinate axis behavior during complex machine motion. Thermal management relies on internal blower cooling, with an integrated fan moving cabinet air through the heat sink.

The enclosure has an IP20 rating for installation in closed electrical panels. For higher-level network communication, the base unit provides a MultiEthernet port that can be configured for EtherNet/IP, PROFINET IRT, or EtherCAT without hardware changes. Motor feedback support is provided through an expansion slot for an Encoder IndraDyn Hiperface/EnDat 2.1/2.2 interface module, which allows high-resolution position data to be processed for accurate axis control. The unit is Design Version 1. The drive does not include an integrated safety interface, and its power section can operate in either infeeding or fed mode.

Communication Interface
SERCOS III master (cross communication)
Control Section Design Type
ADVANCED
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
18 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
MultiEthernet
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 110...230 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'ADVANCED' (A)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Safety Interface
Not equipped
  • HCS011EW0018A02ACCECETNNNNFW
  • HCS01 1E W0018 A 02 A CC EC ET NN NN FW
  • hcs01.1e-w0013-a-02-a-et-ec-nn-l4-nn-fw
  • HCS1.1E-W0018-A-02-A-CC-EC-ET-NN-NN-FW

Frequently Asked Questions about HCS01.1E-W0018-A-02-A-CC-EC-ET-NN-NN-FW:

Q: What type of cooling method does the HCS01.1E-W0018-A-02-A-CC-EC-ET-NN-NN-FW drive controller utilize?

A: The HCS01.1E-W0018-A-02-A-CC-EC-ET-NN-NN-FW includes an internal air cooling system using an integrated blower for temperature management.

Q: What is the specified mains voltage range for the HCS01.1E-W0018-A-02-A-CC-EC-ET-NN-NN-FW?

A: This controller supports a mains voltage of 3 x AC 110 to 230 V with a tolerance of ±10%, suiting a broad range of power environments.

Q: What is the device peak current for the HCS01.1E-W0018-A-02-A-CC-EC-ET-NN-NN-FW?

A: The peak current supported by this device is 18 A, enabling it to handle significant load demands in automation systems.

Q: What is the second interface type provided on the HCS01.1E-W0018-A-02-A-CC-EC-ET-NN-NN-FW?

A: This model offers a MultiEthernet interface as its second interface type, enhancing connectivity with various network protocols.

Q: What is the IP rating of the HCS01.1E-W0018-A-02-A-CC-EC-ET-NN-NN-FW drive controller?

A: The Ingress Protection rating for this drive controller is IP20, meaning it is protected against solid objects larger than 12 mm and offers no protection against liquids.


Internal Product Review

  • ‘‘The HCS01.1E-W0018-A-02-A-CC-EC-ET-NN-NN-FW is an HCS Drive Controller with an ADVANCED control section. SERCOS III master cross communication and MultiEthernet support give the controller excellent network flexibility for demanding motion applications. Operation on 3 x AC 110...230 V ±10% with 18 A peak current makes this model a strong performer for compact drive systems.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo