HCS01.1E-W0013-A-02-E-S3-EC-NN-L3-NN-FW Bosch Rexroth Indramat
MPN: R911339621
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat HCS01.1E-W0013-A-02-E-S3-EC-NN-L3-NN-FW is part of the HCS IndraDrive Controllers series and has a peak device current of 13 Amps. This HCS drive controller features an integrated blower for air cooling, an IP20 rating, and is equipped with SERCOS III communication interface. The controller uses the ECONOMY design and supports encoder interfaces such as IndraDyn Hiperface and EnDat 2.1/2.2.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The HCS01.1E-W0013-A-02-E-S3-EC-NN-L3-NN-FW is a drive controller built by Bosch Rexroth Indramat for the HCS IndraDrive Controllers series. As an HCS drive controller, it provides closed-loop regulation for synchronous and asynchronous servo motors in automated machinery. It belongs to the compact HCS01 line and serves as the power and control unit that converts factory mains into regulated output while exchanging motion commands with higher-level PLCs. Within an automation cell, it coordinates torque, speed, and position functions so actuators follow programmed trajectories with stable axis response.
The controller operates from a three-phase supply of 3 x AC 110...230 V ±10%, allowing direct connection to low-voltage plants without an isolation transformer. Its device peak current is rated at 13 A, which is the maximum short-term motor current the drive can deliver during acceleration or load transients. Heat generated under those conditions is removed by internal air cooling, which uses an integrated blower and eliminates the need for external ducting. Protection against accidental contact is limited to the IP20 enclosure class, so installation inside a switch cabinet is required. Real-time axis coordination is carried over the SERCOS III communication bus, providing deterministic cycle times for multi-axis systems. The unit is design version 1 and matches the current mechanical footprint of the HCS01 frame.
Safety functions are handled through the integrated STO interface, which removes motor torque without shutting down the complete controller circuitry. The unit is paired with a control section identified as ECONOMY for standard motion tasks. Power is exchanged with the DC bus by an infeeding and regenerative feed configuration, enabling regenerative energy to be shared across multiple drives. Feedback from rotary or linear motors is accepted through the Encoder IndraDyn Hiperface/EnDat 2.1/2.2 port, which supports motor commutation and position transmission during operation. The second feedback channel is intentionally left unpopulated, which simplifies wiring for applications that do not need an additional feedback interface.
Frequently Asked Questions about HCS01.1E-W0013-A-02-E-S3-EC-NN-L3-NN-FW:
Q: What communication interface does the HCS01.1E-W0013-A-02-E-S3-EC-NN-L3-NN-FW use?
A: The HCS01.1E-W0013-A-02-E-S3-EC-NN-L3-NN-FW supports communication via SERCOS III protocol.
Q: How is the HCS01.1E-W0013-A-02-E-S3-EC-NN-L3-NN-FW cooled?
A: This drive controller uses an internal air cooling method with an integrated blower for temperature regulation.
Q: What type of safety interface does the HCS01.1E-W0013-A-02-E-S3-EC-NN-L3-NN-FW provide?
A: The device is equipped with a Safe Torque Off (STO) safety interface for operational security.
Q: What is the peak current capacity of the HCS01.1E-W0013-A-02-E-S3-EC-NN-L3-NN-FW?
A: This model is rated for a peak current output of 13 A during operation.
Q: What encoder interface options are supported on the HCS01.1E-W0013-A-02-E-S3-EC-NN-L3-NN-FW?
A: The compatible encoder interface for this controller includes IndraDyn Hiperface and EnDat 2.1/2.2.