HCS01.1E-W0013-A-02-B-ET-EC-PB-NN-AA-FW Bosch Rexroth Indramat
MPN: R911331047
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat HCS01.1E-W0013-A-02-B-ET-EC-PB-NN-AA-FW is a drive controller from the HCS IndraDrive Controllers series. It features an internal air cooling system with integrated blower and operates at a peak current of 13 Amps. This controller includes MultiEthernet and PROFIBUS communication interfaces, and supports encoder connections via IndraDyn Hiperface or EnDat 2.1/2.2, with an IP20 protection rating.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The HCS01.1E-W0013-A-02-B-ET-EC-PB-NN-AA-FW is a drive controller manufactured by Bosch Rexroth Indramat within the HCS IndraDrive Controllers series. It converts mains power into regulated three-phase output for synchronous or induction servomotors and exchanges real-time data with higher-level automation equipment. The unit belongs to the compact HCS01 line and is intended for panel mounting inside control cabinets, where it coordinates motion axes in packaging machinery, handling modules, and other factory automation stations. This arrangement lets the controller serve as a compact power and communication node for a cabinet-mounted axis.
With its MultiEthernet port, the controller can join Profinet, EtherNet/IP, or EtherCAT networks without additional hardware. The power stage supplies up to 13 A of peak current, which suits small-to-medium mechanical loads and short acceleration demands. An IP20 enclosure allows touch-safe installation when the controller is mounted inside a suitable cabinet. The unit accepts a broad input of 3 × AC 110…230 V ±10%, which supports operation from a wide range of cabinet power systems. For motor feedback, it integrates the Encoder IndraDyn Hiperface/EnDat 2.1/2.2 interface, and machine-level communication is available through the onboard PROFIBUS channel.
The unit uses design version 1 and a control section coded as BASIC, which keeps the feature set straightforward. Cooling is provided by internal air cooling driven by an integrated blower, so no external fan tray is required. The power module supports infeeding or fed operation, which allows it to either supply energy to a common DC bus or receive it when operating as a single axis. Because no integrated safety interface is equipped, regulated stop and emergency stop functions must be handled by external safety components or by a drive variant with built-in safety.
Frequently Asked Questions about HCS01.1E-W0013-A-02-B-ET-EC-PB-NN-AA-FW:
Q: What communication interface is integrated on the HCS01.1E-W0013-A-02-B-ET-EC-PB-NN-AA-FW?
A: This drive controller supports MultiEthernet for convenient and versatile industrial networking.
Q: What cooling method does the HCS01.1E-W0013-A-02-B-ET-EC-PB-NN-AA-FW controller utilize?
A: The HCS01.1E-W0013-A-02-B-ET-EC-PB-NN-AA-FW model uses an internal air cooling system with an integrated blower.
Q: What is the peak current rating of the HCS01.1E-W0013-A-02-B-ET-EC-PB-NN-AA-FW?
A: This controller operates at a device peak current of 13 A, providing high-performance output for demanding applications.
Q: What mains voltage range can the HCS01.1E-W0013-A-02-B-ET-EC-PB-NN-AA-FW accept?
A: The mains voltage specification for this controller is 3 x AC 110...230 V ±10%.
Q: Is a safety interface provided on the HCS01.1E-W0013-A-02-B-ET-EC-PB-NN-AA-FW model?
A: The safety interface is not equipped on the HCS01.1E-W0013-A-02-B-ET-EC-PB-NN-AA-FW drive controller.