The Bosch Rexroth Indramat HCS01.1E-W0013-A-02-B-ET-EC-PB-L3-NN-FW is a drive controller from the HCS IndraDrive Controllers series. It features a MultiEthernet communication interface and supports PROFIBUS as a secondary interface. The controller offers 13 Amps peak device current, utilizes internal air cooling through an integrated blower, and holds an IP20 rating.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The HCS01.1E-W0013-A-02-B-ET-EC-PB-L3-NN-FW is a drive controller produced by Bosch Rexroth Indramat and delivered as part of the HCS IndraDrive Controllers series. Designed for cabinet installation, the unit regulates power to synchronous and asynchronous motors in automated machinery, coordinating torque and speed to match commanded motion profiles. It is design version 1 and uses an infeeding power supply arrangement so regenerated energy can be returned to or drawn from a common DC link.
Its power electronics can deliver a peak output of 13 A to the connected motor, permitting short bursts of acceleration without saturation. The power stage accepts a mains supply of 3 x AC 110–230 V ±10%, enabling global use on low-voltage three-phase grids. Networked motion control is supported through the MultiEthernet interface, which hosts protocols such as EtherNet/IP and SERCOS over a single port. Functional safety is handled by the integrated STO (Safe Torque Off) channel, allowing rapid removal of drive energy during emergency stops. An IP20 enclosure rating limits the controller to mounting inside a closed control panel where ingress protection is provided by the surrounding cabinet.
For thermal management, the converter uses internal air cooling through an integrated blower, so heat is ejected directly into the switchgear air path without external ducting. The control section supplied with the unit is marked BASIC, which provides standard PLCopen function blocks and parameter access without advanced technology options. Feedback from the motor is processed through the IndraDyn Hiperface/EnDat 2.1/2.2 encoder interface, enabling absolute position resolution up to single-turn accuracy. Machine-level communication to legacy cells remains possible through the separate PROFIBUS channel, allowing deterministic cyclic data exchange between the drive and supervisory controllers during retrofit projects.
Frequently Asked Questions about HCS01.1E-W0013-A-02-B-ET-EC-PB-L3-NN-FW:
Q: What type of communication interface is available on the HCS01.1E-W0013-A-02-B-ET-EC-PB-L3-NN-FW drive controller?
A: The HCS01.1E-W0013-A-02-B-ET-EC-PB-L3-NN-FW supports MultiEthernet for versatile communication with automation systems.
Q: What is the mains voltage requirement for the HCS01.1E-W0013-A-02-B-ET-EC-PB-L3-NN-FW?
A: This drive controller operates at a mains voltage range of 3 x AC 110 to 230 V with a ±10% tolerance.
Q: What is the peak current capacity of the HCS01.1E-W0013-A-02-B-ET-EC-PB-L3-NN-FW?
A: The maximum device peak current for this model is 13 A.
Q: How is the HCS01.1E-W0013-A-02-B-ET-EC-PB-L3-NN-FW cooled during operation?
A: The cooling method used in this drive controller is internal air cooling through an integrated blower.
Q: What safety functionality is provided by the HCS01.1E-W0013-A-02-B-ET-EC-PB-L3-NN-FW drive controller?
A: This model features a Safe Torque Off (STO) safety interface for secure operation.