The Bosch Rexroth Indramat HCS01.1E-W0013-A-02-B-ET-EC-NN-SB-NN-FW is an HCS IndraDrive Controller featuring a device peak current of 13 Amps and supports a MultiEthernet communication interface. This controller uses internal air cooling through an integrated blower and maintains an IP20 rating. It is equipped with an encoder interface compatible with IndraDyn Hiperface or EnDat 2.1 and 2.2 protocols.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0013-A-02-B-ET-EC-NN-SB-NN-FW is a drive controller produced by Bosch Rexroth Indramat within the HCS IndraDrive Controllers series. It functions as a compact inverter that conditions incoming three-phase power and modulates current to servo and induction motors, forming the core actuator interface in automated assembly lines, packaging equipment, and material-handling axes. Motion logic is executed by the BASIC control section, which matches the intended control architecture for this power module.

It draws power from a three-phase mains of 3 x AC 110–230 V ±10%, so the controller fits low-voltage factory circuits without step-down transformers. Communication with the plant network is handled through MultiEthernet, allowing multiple standard industrial protocols on the same port. The power stage can deliver up to 13 A of peak current to the connected motor, which supports short-term acceleration and braking torque at the axis. For thermal management, the housing uses internal air cooling driven by an integrated blower, moving cabinet air across the heat sink instead of relying on external ducts. Its enclosure carries an IP20 rating, so it must be installed inside a protected electrical cabinet to avoid contact with live parts.

The signal path for feedback is stabilized by the dedicated IndraDyn Hiperface/EnDat 2.1/2.2 encoder interface on Interface 1, while Interface 2 remains unequipped for optional expansion. The unit is design version 1, which indicates the first mechanical release of the HCS01 line. DC-bus energy moves through an infeeding and regenerative feed arrangement, so the drive can supply neighboring converters or absorb returned energy during deceleration. The controller remains a standard build without added optional features beyond the installed interface and control configuration.

Communication Interface
MultiEthernet
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
13 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Not equipped
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 110...230 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
  • HCS011EW0013A02BETECNNSBNNFW
  • HCS01 1E W0013 A 02 B ET EC NN SB NN FW
  • hcs01.1e-w0013-a-02-a-cc-ec-em-nn-nn-fw
  • HCS1.1E-W0013-A-02-B-ET-EC-NN-SB-NN-FW

Frequently Asked Questions about HCS01.1E-W0013-A-02-B-ET-EC-NN-SB-NN-FW:

Q: What type of communication interface does the HCS01.1E-W0013-A-02-B-ET-EC-NN-SB-NN-FW drive controller provide?

A: The HCS01.1E-W0013-A-02-B-ET-EC-NN-SB-NN-FW drive controller features a MultiEthernet communication interface for connectivity.

Q: How is the HCS01.1E-W0013-A-02-B-ET-EC-NN-SB-NN-FW drive controller cooled?

A: This model uses an internal air cooling system through an integrated blower for temperature management.

Q: What is the peak current capability of the HCS01.1E-W0013-A-02-B-ET-EC-NN-SB-NN-FW?

A: The peak device current for this controller is 13 A, allowing for short bursts of high performance.

Q: What mains voltage range does the HCS01.1E-W0013-A-02-B-ET-EC-NN-SB-NN-FW support?

A: It is compatible with 3-phase AC mains voltages from 110 to 230 V ±10%.

Q: Which types of encoder interfaces are available on the HCS01.1E-W0013-A-02-B-ET-EC-NN-SB-NN-FW?

A: Its encoder interface supports IndraDyn Hiperface and EnDat 2.1/2.2 types for feedback systems.


Internal Product Review

  • ‘‘The HCS01.1E-W0013-A-02-B-ET-EC-NN-SB-NN-FW is an HCS Drive Controller with a BASIC control section and MultiEthernet communication. Internal blower cooling and IP20 protection support dependable cabinet operation in standard industrial installations. A 13 A peak current rating with 3 x AC 110...230 V mains input makes the unit a strong fit for compact IndraDrive motion systems.’’