HCS01.1E-W0013-A-02-B-ET-EC-NN-S4-NN-FW Bosch Rexroth Indramat
MPN: R911341042
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat HCS01.1E-W0013-A-02-B-ET-EC-NN-S4-NN-FW is an HCS Drive Controller from the HCS IndraDrive Controllers series. This unit features a MultiEthernet communication interface and supports mains voltages of 3 x AC 110 to 230 V. It has a device peak current of 13 Amps, an IP20 protection rating, and uses internal air cooling with an integrated blower.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The HCS01.1E-W0013-A-02-B-ET-EC-NN-S4-NN-FW is a drive controller produced by Bosch Rexroth Indramat for the HCS IndraDrive Controllers series. As a compact HCS01 unit, it serves as the power and control stage between the mains supply and a synchronous or induction motor in automated machinery. It delivers regulated current, processes position feedback, and exchanges motion data with higher-level controllers during coordinated axis operation. This makes it suitable for packaging equipment, material-handling systems, and light assembly stations where compact cabinet hardware is preferred. Its compact format also helps it fit installations where available panel space is limited.
Communication is provided by a Multi-Ethernet port, allowing the controller to join EtherNet/IP, PROFINET, or EtherCAT networks without additional option cards. The mains input accepts 3 x AC 110…230 V ±10%, so the unit can connect directly to low-voltage three-phase supplies. Up to 13 A of peak current supports brief torque surges during acceleration or load changes. Heat is removed by internal air cooling through an integrated blower, and the housing has an IP20 rating for cabinet installation. The primary feedback channel supports an IndraDyn encoder with Hiperface or EnDat 2.1/2.2 connection, while the second encoder interface is not used in single-encoder applications.
The controller uses the BASIC control section for standard drive functions. Its design version is 1, which identifies the hardware revision used for this model. The DC bus supports infeeding and fed operation, so the unit can either receive power from an upstream supply or share regenerated energy within a multi-axis group. Clean, filtered cabinet airflow should be maintained around the unit so the cooling path remains effective during sustained operation.
Frequently Asked Questions about HCS01.1E-W0013-A-02-B-ET-EC-NN-S4-NN-FW:
Q: What type of communication interface is available on the HCS01.1E-W0013-A-02-B-ET-EC-NN-S4-NN-FW controller?
A: The HCS01.1E-W0013-A-02-B-ET-EC-NN-S4-NN-FW drive controller supports a MultiEthernet communication interface for flexible network integration.
Q: How is the HCS01.1E-W0013-A-02-B-ET-EC-NN-S4-NN-FW drive controller cooled?
A: Cooling is achieved through an internal air system utilizing an integrated blower for thermal management.
Q: What is the peak current capacity of the HCS01.1E-W0013-A-02-B-ET-EC-NN-S4-NN-FW controller?
A: This model offers a device peak current of 13 A for demanding drive applications.
Q: What mains voltage range does the HCS01.1E-W0013-A-02-B-ET-EC-NN-S4-NN-FW drive controller support?
A: The mains voltage range supported is 3 x AC 110 to 230 V ±10%, suitable for various electrical setups.
Q: What encoder interface does the HCS01.1E-W0013-A-02-B-ET-EC-NN-S4-NN-FW controller offer?
A: For encoder feedback, this unit provides an IndraDyn Hiperface/EnDat 2.1/2.2 interface.