4.95 based on 202 reviews

🙶 Easy to navigate website and quick responses from support. Additionally, pretty fast shipping. Our mainte... 🙷

HCS01.1E-W0013-A-02-B-ET-EC-NN-S4-NN-FW Bosch Rexroth Indramat

MPN: R911341042

No Tariffs On US Orders
  • Rated 4.5 (42 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
In-Stock, Ships 3-5 Days

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0013-A-02-B-ET-EC-NN-S4-NN-FW is an HCS Drive Controller from the HCS IndraDrive Controllers series. This unit features a MultiEthernet communication interface and supports mains voltages of 3 x AC 110 to 230 V. It has a device peak current of 13 Amps, an IP20 protection rating, and uses internal air cooling with an integrated blower.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0013-A-02-B-ET-EC-NN-S4-NN-FW is a drive controller produced by Bosch Rexroth Indramat for the HCS IndraDrive Controllers series. As a compact HCS01 unit, it serves as the power and control stage between the mains supply and a synchronous or induction motor in automated machinery. It delivers regulated current, processes position feedback, and exchanges motion data with higher-level controllers during coordinated axis operation. This makes it suitable for packaging equipment, material-handling systems, and light assembly stations where compact cabinet hardware is preferred. Its compact format also helps it fit installations where available panel space is limited.

Communication is provided by a Multi-Ethernet port, allowing the controller to join EtherNet/IP, PROFINET, or EtherCAT networks without additional option cards. The mains input accepts 3 x AC 110…230 V ±10%, so the unit can connect directly to low-voltage three-phase supplies. Up to 13 A of peak current supports brief torque surges during acceleration or load changes. Heat is removed by internal air cooling through an integrated blower, and the housing has an IP20 rating for cabinet installation. The primary feedback channel supports an IndraDyn encoder with Hiperface or EnDat 2.1/2.2 connection, while the second encoder interface is not used in single-encoder applications.

The controller uses the BASIC control section for standard drive functions. Its design version is 1, which identifies the hardware revision used for this model. The DC bus supports infeeding and fed operation, so the unit can either receive power from an upstream supply or share regenerated energy within a multi-axis group. Clean, filtered cabinet airflow should be maintained around the unit so the cooling path remains effective during sustained operation.

Communication Interface
MultiEthernet
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
13 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Not equipped
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 110...230 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
  • HCS011EW0013A02BETECNNS4NNFW
  • HCS01 1E W0013 A 02 B ET EC NN S4 NN FW
  • hcs01.1e-w0013-a-02-a-cc-ec-ec-nn-nn-fw
  • HCS1.1E-W0013-A-02-B-ET-EC-NN-S4-NN-FW

Frequently Asked Questions about HCS01.1E-W0013-A-02-B-ET-EC-NN-S4-NN-FW:

Q: What type of communication interface is available on the HCS01.1E-W0013-A-02-B-ET-EC-NN-S4-NN-FW controller?

A: The HCS01.1E-W0013-A-02-B-ET-EC-NN-S4-NN-FW drive controller supports a MultiEthernet communication interface for flexible network integration.

Q: How is the HCS01.1E-W0013-A-02-B-ET-EC-NN-S4-NN-FW drive controller cooled?

A: Cooling is achieved through an internal air system utilizing an integrated blower for thermal management.

Q: What is the peak current capacity of the HCS01.1E-W0013-A-02-B-ET-EC-NN-S4-NN-FW controller?

A: This model offers a device peak current of 13 A for demanding drive applications.

Q: What mains voltage range does the HCS01.1E-W0013-A-02-B-ET-EC-NN-S4-NN-FW drive controller support?

A: The mains voltage range supported is 3 x AC 110 to 230 V ±10%, suitable for various electrical setups.

Q: What encoder interface does the HCS01.1E-W0013-A-02-B-ET-EC-NN-S4-NN-FW controller offer?

A: For encoder feedback, this unit provides an IndraDyn Hiperface/EnDat 2.1/2.2 interface.


Internal Product Review

  • ‘‘The HCS01.1E-W0013-A-02-B-ET-EC-NN-S4-NN-FW is an HCS drive controller built around a BASIC control section. MultiEthernet support and encoder compatibility with IndraDyn Hiperface or EnDat 2.1/2.2 make integration efficient in modern motion systems. Internal blower cooling and a 13 A peak current give this controller strong practical value for compact servo applications.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo