MPN: R911336243
The Bosch Rexroth Indramat HCS01.1E-W0013-A-02-B-ET-EC-NN-L3-NN-FW is part of the HCS IndraDrive Controllers series. This HCS drive controller features a MultiEthernet communication interface and supports IndraDyn Hiperface and EnDat encoder options. It has a peak current of 13 Amps, an IP20 rating, and is cooled through an integrated blower.
Internal Product Review
The HCS01.1E-W0013-A-02-B-ET-EC-NN-L3-NN-FW is an HCS drive controller configured with MultiEthernet communication and a BASIC control section. Internal air cooling through an integrated blower supports stable thermal management, while STO (Safe Torque Off) adds valuable machine-side protection. IP20 protection and 13 A peak current make the controller a strong fit for demanding industrial drive applications.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The HCS01.1E-W0013-A-02-B-ET-EC-NN-L3-NN-FW is a drive controller manufactured by Bosch Rexroth Indramat for the HCS IndraDrive Controllers series. It converts incoming mains power into regulated three-phase output for synchronous and induction motors, allowing closed-loop positioning and speed control in automated assembly cells, pick-and-place gantries, and compact packaging machines. This role lets the unit serve as both the power stage and a central motion component for compact industrial axes that need repeatable response during continuous operation. Its compact form also suits cabinet installations where space is limited but accurate motor control is still required.
This controller communicates with higher-level PLCs through a MultiEthernet interface that supports several Ethernet-based fieldbuses without a hardware change. For supply power, it accepts 3 × AC 110…230 V ±10%, which makes it suitable for a wide range of low-voltage industrial systems. Thermal management relies on internal air cooling generated by an integrated blower, so no external liquid loop is required. During acceleration or short overloads, the inverter can supply up to 13 A of peak current. The housing has an IP20 rating and is intended for installation inside a closed control cabinet.
The encoder port supports IndraDyn Hiperface and EnDat 2.1/2.2 feedback, allowing high-resolution position data to reach the drive control electronics. A hardware channel for STO (Safe Torque Off) disconnects gate signals to the IGBTs when a safety relay opens, providing a basic integrated safety function. The power stage uses a common DC bus with bidirectional infeed operation, which supports energy flow in either direction as required by the axis. It is paired with a control section of the BASIC design type for standard motion tasks.