HCS01.1E-W0013-A-02-B-ET-EC-EP-S5-NN-FW Bosch Rexroth Indramat
MPN: R911384634
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
Current response time:
5 Minutes
19 Seconds
The Bosch Rexroth Indramat HCS01.1E-W0013-A-02-B-ET-EC-EP-S5-NN-FW is a drive controller in the HCS IndraDrive Controllers series. It features a MultiEthernet communication interface and a peak current of 13 Amps. This controller uses air cooling through an integrated blower and operates with a mains voltage of 3-phase AC 110 to 230 Volts.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The HCS01.1E-W0013-A-02-B-ET-EC-EP-S5-NN-FW is a drive controller produced by Bosch Rexroth Indramat as part of the HCS IndraDrive Controllers series. It is installed between the line supply and the motor to modulate current and voltage so that industrial axes follow commanded motion profiles. This unit is design version 1 and provides closed-loop control of servo and induction motors while exchanging status data with supervisory control systems. Because it regulates motor current in response to command signals and feedback, it can support repeatable positioning, controlled acceleration, and stable speed operation in automated machinery.
The controller links to factory networks through the MultiEthernet communication port, allowing real-time parameter access through multiple PLC protocols. It accepts a supply of 3 x AC 110...230 V ±10% and can deliver a peak output current of 13 A during transient motor demands. Rotor position and speed feedback are handled through the IndraDyn Hiperface and EnDat 2.1/2.2 encoder interface, enabling high-resolution commutation and accurate speed control. The enclosure is rated IP20, so the device is intended for installation inside a control cabinet with controlled ambient conditions. This cabinet-mounted arrangement helps protect the electronics from incidental contact and exposure to dust that would be more common at the machine surface.
The drive uses the BASIC control section, which provides standard axis functions without optional safety or motion extensions. Thermal management relies on internal air cooling driven by an integrated blower that channels cabinet air across the heat sink. This arrangement supports standard motion tasks while keeping the cooling method simple for enclosed installations. Within the IndraDrive family, it is part of line HCS01 and is used with motors and power supplies sized for low-to-medium power axes. Energy is supplied by a common DC link configured for infeeding and fed operation, so regenerated power can be shared among connected axes or returned to the line supply depending on system topology.
Frequently Asked Questions about HCS01.1E-W0013-A-02-B-ET-EC-EP-S5-NN-FW:
Q: What communication interface is available on the HCS01.1E-W0013-A-02-B-ET-EC-EP-S5-NN-FW drive controller?
A: This model supports MultiEthernet communication, allowing integration with various Ethernet-based automation networks.
Q: What is the device peak current capability of the HCS01.1E-W0013-A-02-B-ET-EC-EP-S5-NN-FW?
A: The device can handle a peak current of 13 A for demanding servo drive applications.
Q: How is the HCS01.1E-W0013-A-02-B-ET-EC-EP-S5-NN-FW cooled?
A: This unit is cooled internally by air through an integrated blower, reducing the need for external cooling solutions.
Q: What mains voltage range does the HCS01.1E-W0013-A-02-B-ET-EC-EP-S5-NN-FW support?
A: It supports mains input voltage from 3 x AC 110 to 230 V with a tolerance of ±10%.
Q: What level of environmental protection does the HCS01.1E-W0013-A-02-B-ET-EC-EP-S5-NN-FW offer?
A: This model has an IP20 rating, providing basic protection against solid objects but not against liquids.