The Bosch Rexroth Indramat HCS01.1E-W0013-A-02-B-ET-EC-DA-NN-NN-FW is a drive controller from the HCS IndraDrive Controllers series. It features a MultiEthernet communication interface and supports encoder interfaces such as IndraDyn Hiperface and EnDat 2.1/2.2. The controller is designed with an internal air cooling method using an integrated blower and offers a device peak current of 13 Amps.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0013-A-02-B-ET-EC-DA-NN-NN-FW drive controller is produced by Bosch Rexroth Indramat and belongs to the HCS IndraDrive Controllers series. It converts incoming AC power into controlled motor output so connected synchronous or asynchronous motors can follow programmed velocity and position commands with stable current regulation. In an automation cell, the unit links the machine PLC to the axis, manages fault monitoring and regenerative energy flow, and keeps the installation compact through the HCS01 form factor. This allows one compact controller to supervise torque production, motor response, and axis behavior during routine machine cycles and repeatable positioning tasks.

The power stage accepts 3 x AC 110 to 230 V with a tolerance of ±10%, allowing the controller to operate from common three-phase industrial supplies. An internal air cooling system with an integrated blower removes switching heat, so the unit does not require an external heat sink for normal installation. Peak output current reaches 13 A, which supports short-term overload demand during acceleration and braking. Energy exchange across a shared DC bus uses infeed and feed operation, and the IP20 enclosure requires the controller to be installed inside a control cabinet. This keeps live components behind the cabinet barrier during normal machine use.

For networked motion control, the drive provides a MultiEthernet port that supports PROFINET, EtherNet/IP, and SERCOS through the same connector, which helps standardize machine wiring across different control platforms and regional network preferences. Motor feedback is handled through the IndraDyn Hiperface/EnDat 2.1/2.2 encoder interface on Interface 1, supplying absolute position information directly to the control loop. The control section uses the BASIC version, and the unit is not equipped with integrated safety, so Safe Torque Off must be handled by external safety hardware. It can therefore serve as both the motion interface and the feedback-processing point for a single cabinet axis. Network communication and position evaluation are kept inside the same controller housing, which reduces the need for separate interface modules.

Communication Interface
MultiEthernet
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
13 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 110...230 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Safety Interface
Not equipped
  • HCS011EW0013A02BETECDANNNNFW
  • HCS01 1E W0013 A 02 B ET EC DA NN NN FW
  • hcs01.1e-w0009-a-02-b-et-ec-em-s4-nn-fw
  • HCS1.1E-W0013-A-02-B-ET-EC-DA-NN-NN-FW

Frequently Asked Questions about HCS01.1E-W0013-A-02-B-ET-EC-DA-NN-NN-FW:

Q: What communication interface does the HCS01.1E-W0013-A-02-B-ET-EC-DA-NN-NN-FW controller offer?

A: The HCS01.1E-W0013-A-02-B-ET-EC-DA-NN-NN-FW features a MultiEthernet communication interface for versatile connectivity.

Q: How is the HCS01.1E-W0013-A-02-B-ET-EC-DA-NN-NN-FW drive controller cooled?

A: Cooling is achieved through an integrated internal blower using air.

Q: What is the device peak current rating of the HCS01.1E-W0013-A-02-B-ET-EC-DA-NN-NN-FW?

A: This controller supports a device peak current of 13 A.

Q: What is the IP rating of the HCS01.1E-W0013-A-02-B-ET-EC-DA-NN-NN-FW controller?

A: The drive controller is rated for IP20 protection against solid objects larger than 12.5 mm.

Q: What mains voltage is required to operate the HCS01.1E-W0013-A-02-B-ET-EC-DA-NN-NN-FW?

A: It operates with a mains voltage supply of 3 x AC 110...230 V ±10%.


Internal Product Review

  • ‘‘The HCS01.1E-W0013-A-02-B-ET-EC-DA-NN-NN-FW is an HCS drive controller with MultiEthernet communication and a BASIC control section. Internal blower cooling and 13 A peak current support stable thermal behavior and responsive drive performance in demanding automation duty. IP20 protection and 3 x AC 110...230 V input make the unit a strong choice for flexible industrial integration.’’