4.95 based on 202 reviews

🙶 Excellent to work with and they stand behind their work. I would highly recommend them. 🙷

HCS01.1E-W0013-A-02-B-ET-EC-CN-L4-NN-FW Bosch Rexroth Indramat

MPN: R911336675

No Tariffs On US Orders
  • Rated 4.4 (34 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Current response time:
6 Minutes 4 Seconds

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0013-A-02-B-ET-EC-CN-L4-NN-FW is part of the HCS IndraDrive Controllers series and features a MultiEthernet communication interface. This drive controller has an air cooling method using an integrated blower, a device peak current of 13 Amps, and provides an IP20 protection rating. It supports encoder interfaces like IndraDyn Hiperface and EnDat 2.1/2.2, and includes STO and SBC safety interfaces.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0013-A-02-B-ET-EC-CN-L4-NN-FW is a HCS Drive Controller produced by Bosch Rexroth Indramat within the HCS IndraDrive Controllers series. The unit supplies and regulates servo and induction motors up to its current limit, forming the central drive element in compact handling modules, conveyors, and assembly stations. By combining power electronics and a modular control section in a single housing, it permits motion control tasks to be executed close to the machine frame, reducing cabinet space and wiring length. This arrangement is well suited to machines that need precise motor control without a large standalone drive cabinet.

This controller connects to higher-level PLCs over MultiEthernet, allowing the same hardware to operate on EtherNet/IP, PROFINET, or EtherCAT networks without change. Its power stage accepts a three-phase input of 3 × AC 110…230 V ±10% and delivers up to 13 A of peak motor current for short acceleration bursts. The enclosure is rated IP20, so installation inside a control cabinet is required to prevent accidental contact with live parts. Thermal management is handled by internal air cooling through an integrated blower, so no external heat sink or liquid circuit is necessary. The combination of network access, moderate current capacity, and cabinet-friendly cooling makes it suitable for compact axis applications.

Functional safety is provided by the integrated STO and SBC channels, enabling immediate torque removal and brake engagement through certified inputs. Motor feedback is processed on the first encoder interface, which supports Encoder IndraDyn Hiperface/EnDat 2.1/2.2 formats, while fieldbus diagnostics and parameter access are available on the dedicated CANopen port. The control section mounted on this power module uses the BASIC design in version 1, providing standard motion functions without optional technology packages. The power supply concept supports both infeeding and fed-back energy modes, which is useful in multi-axis configurations that share a common DC bus.

Communication Interface
MultiEthernet
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
13 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
CANopen
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 110...230 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Safety Interface
STO (Safe Torque Off) and SBC (Safe Brake Control)
  • HCS011EW0013A02BETECCNL4NNFW
  • HCS01 1E W0013 A 02 B ET EC CN L4 NN FW
  • hcs01.1e-w0009-a-02-b-et-ec-em-l3-nn-fw
  • HCS1.1E-W0013-A-02-B-ET-EC-CN-L4-NN-FW

Frequently Asked Questions about HCS01.1E-W0013-A-02-B-ET-EC-CN-L4-NN-FW:

Q: What is the maximum peak current rating of the HCS01.1E-W0013-A-02-B-ET-EC-CN-L4-NN-FW controller?

A: This drive controller has a peak output current of 13 A, supporting applications with medium power demands.

Q: What communication interface options are available on the HCS01.1E-W0013-A-02-B-ET-EC-CN-L4-NN-FW controller?

A: The HCS01.1E-W0013-A-02-B-ET-EC-CN-L4-NN-FW is equipped with a MultiEthernet interface for versatile communication options.

Q: What cooling method is used in the HCS01.1E-W0013-A-02-B-ET-EC-CN-L4-NN-FW drive controller?

A: Internal air cooling is utilized in this model via an integrated blower for heat dissipation.

Q: What mains voltage range does the HCS01.1E-W0013-A-02-B-ET-EC-CN-L4-NN-FW support?

A: The controller operates with a 3-phase AC input voltage ranging from 110 to 230 V ±10%.

Q: What safety interfaces are implemented in the HCS01.1E-W0013-A-02-B-ET-EC-CN-L4-NN-FW drive controller?

A: This controller provides safety through STO (Safe Torque Off) and SBC (Safe Brake Control) interfaces.


Internal Product Review

  • ‘‘The HCS01.1E-W0013-A-02-B-ET-EC-CN-L4-NN-FW is an HCS drive controller that stands out with MultiEthernet communication and a BASIC control section. With 13 A peak current and STO/SBC safety functions, the controller is a well-balanced choice for dependable IndraDrive integration.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo