HCS01.1E-W0013-A-02-A-ET-EC-NN-S4-NN-FW Bosch Rexroth Indramat
MPN: R911401326
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat HCS01.1E-W0013-A-02-A-ET-EC-NN-S4-NN-FW is a drive controller from the HCS IndraDrive Controllers series with a device peak current of 13 Amps and MultiEthernet communication interface. It supports air cooling through an integrated blower and offers an IP20 protection rating. This controller features an encoder interface compatible with IndraDyn Hiperface and EnDat 2.1/2.2 and operates at a mains voltage of 3-phase AC 110 to 230 Volts.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The HCS01.1E-W0013-A-02-A-ET-EC-NN-S4-NN-FW is a drive controller manufactured by Bosch Rexroth Indramat for the HCS IndraDrive Controllers series. As a closed-loop power stage, it receives three-phase supply energy, processes feedback from attached motors, and generates pulse-width-modulated output for motion control. This output maintains commanded torque, speed, or position in automated production lines and material-handling cells. It is suited for axes that require coordinated response to changing load and speed commands during machine cycles.
This controller operates from a mains window of 3 x AC 110…230 V ±10%, allowing use on single- or dual-voltage plants without an autotransformer. The device peak current is 13 A, which is the maximum short-term motor current the unit can supply during rapid acceleration or load spikes. Thermal management relies on internal air cooling through an integrated blower, so cabinet airflow does not need to be directed across the heat sink. The housing has an IP20 rating, which provides finger-safe access and requires installation inside a protected enclosure. Command and diagnostic data travel over MultiEthernet, allowing support for common industrial Ethernet protocols through a single port. This arrangement helps keep panel wiring straightforward in compact cabinets.
An Encoder IndraDyn Hiperface/EnDat 2.1/2.2 interface is fitted for high-resolution position feedback. That feedback arrangement supports precise commutation and position monitoring across a wide operating range. The second interface slot is not populated, which keeps the footprint small and focuses wiring on the primary feedback channel. The unit is released as version 1 and is intended to pair with a BASIC control section, forming a complete axis controller when the logic module is inserted. Its DC link uses an Infeeding / Feeded topology, which lets the axis draw energy from and return energy to the common bus during regenerative braking.
Frequently Asked Questions about HCS01.1E-W0013-A-02-A-ET-EC-NN-S4-NN-FW:
Q: What communication interface is supported by the HCS01.1E-W0013-A-02-A-ET-EC-NN-S4-NN-FW controller?
A: The HCS01.1E-W0013-A-02-A-ET-EC-NN-S4-NN-FW controller supports MultiEthernet communication for flexible network integration.
Q: How is the HCS01.1E-W0013-A-02-A-ET-EC-NN-S4-NN-FW cooled during operation?
A: This drive controller uses internal air cooling via an integrated blower.
Q: What is the peak current supported by the HCS01.1E-W0013-A-02-A-ET-EC-NN-S4-NN-FW unit?
A: The device operates with a peak current of 13 A, suitable for medium current drive applications.
Q: What type of IP rating does the HCS01.1E-W0013-A-02-A-ET-EC-NN-S4-NN-FW have?
A: This model features an IP20 rating, providing basic protection against solid objects greater than 12.5mm.
Q: What is the mains voltage range required for the HCS01.1E-W0013-A-02-A-ET-EC-NN-S4-NN-FW controller?
A: It is designed to work with a three-phase AC mains voltage between 110 and 230 V plus or minus 10%.