4.95 based on 202 reviews

🙶 We have never had a problem in the almost 20 years we have dealt with Wake. We would recommend them to any... 🙷

HCS01.1E-W0013-A-02-A-ET-EC-NN-S4-NN-FW Bosch Rexroth Indramat

MPN: R911401326

No Tariffs On US Orders
  • Rated 4.5 (49 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0013-A-02-A-ET-EC-NN-S4-NN-FW is a drive controller from the HCS IndraDrive Controllers series with a device peak current of 13 Amps and MultiEthernet communication interface. It supports air cooling through an integrated blower and offers an IP20 protection rating. This controller features an encoder interface compatible with IndraDyn Hiperface and EnDat 2.1/2.2 and operates at a mains voltage of 3-phase AC 110 to 230 Volts.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0013-A-02-A-ET-EC-NN-S4-NN-FW is a drive controller manufactured by Bosch Rexroth Indramat for the HCS IndraDrive Controllers series. As a closed-loop power stage, it receives three-phase supply energy, processes feedback from attached motors, and generates pulse-width-modulated output for motion control. This output maintains commanded torque, speed, or position in automated production lines and material-handling cells. It is suited for axes that require coordinated response to changing load and speed commands during machine cycles.

This controller operates from a mains window of 3 x AC 110…230 V ±10%, allowing use on single- or dual-voltage plants without an autotransformer. The device peak current is 13 A, which is the maximum short-term motor current the unit can supply during rapid acceleration or load spikes. Thermal management relies on internal air cooling through an integrated blower, so cabinet airflow does not need to be directed across the heat sink. The housing has an IP20 rating, which provides finger-safe access and requires installation inside a protected enclosure. Command and diagnostic data travel over MultiEthernet, allowing support for common industrial Ethernet protocols through a single port. This arrangement helps keep panel wiring straightforward in compact cabinets.

An Encoder IndraDyn Hiperface/EnDat 2.1/2.2 interface is fitted for high-resolution position feedback. That feedback arrangement supports precise commutation and position monitoring across a wide operating range. The second interface slot is not populated, which keeps the footprint small and focuses wiring on the primary feedback channel. The unit is released as version 1 and is intended to pair with a BASIC control section, forming a complete axis controller when the logic module is inserted. Its DC link uses an Infeeding / Feeded topology, which lets the axis draw energy from and return energy to the common bus during regenerative braking.

Communication Interface
MultiEthernet
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
13 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Not equipped
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 110...230 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
  • HCS011EW0013A02AETECNNS4NNFW
  • HCS01 1E W0013 A 02 A ET EC NN S4 NN FW
  • hcs01.1e-w0009-a-02-b-et-ec-ec-s4-nn-fw
  • HCS1.1E-W0013-A-02-A-ET-EC-NN-S4-NN-FW

Frequently Asked Questions about HCS01.1E-W0013-A-02-A-ET-EC-NN-S4-NN-FW:

Q: What communication interface is supported by the HCS01.1E-W0013-A-02-A-ET-EC-NN-S4-NN-FW controller?

A: The HCS01.1E-W0013-A-02-A-ET-EC-NN-S4-NN-FW controller supports MultiEthernet communication for flexible network integration.

Q: How is the HCS01.1E-W0013-A-02-A-ET-EC-NN-S4-NN-FW cooled during operation?

A: This drive controller uses internal air cooling via an integrated blower.

Q: What is the peak current supported by the HCS01.1E-W0013-A-02-A-ET-EC-NN-S4-NN-FW unit?

A: The device operates with a peak current of 13 A, suitable for medium current drive applications.

Q: What type of IP rating does the HCS01.1E-W0013-A-02-A-ET-EC-NN-S4-NN-FW have?

A: This model features an IP20 rating, providing basic protection against solid objects greater than 12.5mm.

Q: What is the mains voltage range required for the HCS01.1E-W0013-A-02-A-ET-EC-NN-S4-NN-FW controller?

A: It is designed to work with a three-phase AC mains voltage between 110 and 230 V plus or minus 10%.


Internal Product Review

  • ‘‘The HCS01.1E-W0013-A-02-A-ET-EC-NN-S4-NN-FW is an HCS drive controller with a MultiEthernet communication interface. Internal blower cooling and IP20 protection make the unit a strong fit for controlled cabinet installations. A 13 A peak current stands out as a solid performance advantage for demanding motion applications.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo