HCS01.1E-W0013-A-02-A-CC-EC-PB-L4-NN-FW Bosch Rexroth Indramat
MPN: R911342254
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat HCS01.1E-W0013-A-02-A-CC-EC-PB-L4-NN-FW is part of the HCS IndraDrive Controllers series and features an ADVANCED control section design. This drive controller supports a peak current of 13 Amps, IP20 protection rating, and operates on 3-phase AC mains voltage from 110 to 230 Volts. It includes SERCOS III master, PROFIBUS, and encoder interfaces, as well as STO and SBC safety functions.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The HCS01.1E-W0013-A-02-A-CC-EC-PB-L4-NN-FW drive controller is produced by Bosch Rexroth Indramat for the HCS IndraDrive Controllers series. The unit supplies closed-loop power to servo axes and integrates easily into distributed automation cells. By combining its power stage with a detachable control section, the device manages speed, position, and torque for packaging, handling, and light machining equipment inside a protected cabinet environment. This arrangement allows the controller to respond quickly to command changes while maintaining stable motor operation during indexing, speed regulation, and positioning tasks. Its modular design separates the control section from the power stage, so service access can be handled without disturbing mains wiring.
It accepts a three-phase supply of 3 x AC 110 to 230 V ±10% and can deliver up to 13 A of peak current during short acceleration bursts. Thermal limits are handled by internal air cooling with an integrated blower, so no external ducting is needed. The housing has an IP20 rating and must be installed inside a switchgear enclosure. Motion data travel over a SERCOS III master link that permits cross-communication and axis synchronization. The power section can operate in infeeding or fed mode, allowing regenerated energy to flow back to the DC bus. Design version 1 is used in the HCS01 line, and no supplemental mechanical options are included.
Control tasks are handled by the ADVANCED control section, which is paired to this power module at the factory. A second fieldbus port offers PROFIBUS connectivity to PLC networks. The primary feedback channel supports IndraDyn Hiperface/EnDat 2.1/2.2 encoder feedback for precise position loops. That combination supports communication with higher-level controls and direct motor feedback within the same drive platform. Functional safety includes STO and SBC, allowing torque shutdown and brake shutdown without external contactors.
Frequently Asked Questions about HCS01.1E-W0013-A-02-A-CC-EC-PB-L4-NN-FW:
Q: What is the peak current supported by the HCS01.1E-W0013-A-02-A-CC-EC-PB-L4-NN-FW controller?
A: The HCS01.1E-W0013-A-02-A-CC-EC-PB-L4-NN-FW drive controller supports a device peak current of 13 A.
Q: What communication interface does the HCS01.1E-W0013-A-02-A-CC-EC-PB-L4-NN-FW use?
A: The main communication interface on this controller is SERCOS III master with cross communication capability.
Q: How is the HCS01.1E-W0013-A-02-A-CC-EC-PB-L4-NN-FW drive controller cooled?
A: This model uses air cooling through an integrated blower for thermal management.
Q: What safety features are available on the HCS01.1E-W0013-A-02-A-CC-EC-PB-L4-NN-FW?
A: The safety interface includes STO (Safe Torque Off) and SBC (Safe Brake Control) functions.
Q: What is the supported mains voltage range for the HCS01.1E-W0013-A-02-A-CC-EC-PB-L4-NN-FW?