4.95 based on 202 reviews

🙶 I have always received exceptional service and support in my many years of working with Wake Industrial. 🙷

HCS01.1E-W0013-A-02-A-CC-EC-NN-L3-NN-FW Bosch Rexroth Indramat

MPN: R911339620

No Tariffs On US Orders
  • Rated 4.6 (77 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0013-A-02-A-CC-EC-NN-L3-NN-FW is an HCS Drive Controller from the HCS IndraDrive Controllers series. It features a peak current of 13 A and uses advanced control section design. The controller includes a SERCOS III master communication interface, encoder IndraDyn Hiperface or EnDat 2.1/2.2 interface, and an IP20 protection rating.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0013-A-02-A-CC-EC-NN-L3-NN-FW is a drive controller produced by Bosch Rexroth Indramat within the HCS IndraDrive Controllers series. In multi-axis automation cells, this unit provides closed-loop regulation and parameter management for IndraDyn servo and spindle motors while linking motion tasks to a higher-level PLC through a deterministic real-time network. This arrangement allows the drive to coordinate motor current, speed, and torque in automated handling, packaging, and machining systems. By integrating power and control electronics in a compact housing, it serves as the core of cabinet-mounted axis modules where precise motion commands are required.

The controller communicates over a SERCOS III master (cross communication) bus, allowing synchronous data exchange among drives and central control. It accepts a mains supply of 3 x AC 110…230 V ±10%, so it can be connected to low-voltage three-phase utility grids without an external transformer. During short accelerations, the power section delivers up to 13 A of peak current, giving headroom for transient load demands. Thermal energy is removed by internal air cooling through an integrated blower, and an enclosure rating of IP20 limits finger ingress while requiring installation inside a protected electrical cabinet. Because the unit uses internal airflow, cabinet layout should leave clear air paths around the heat-generating sections. The drive is design version 1, and the secondary interface bay is not equipped, so the unit uses a single encoder channel.

The control section is the ADVANCED variant, paired to the power unit at the factory so extended servo functions are available without additional cards. Integrated functional safety is provided by STO (Safe Torque Off), which removes drive energy when the safety circuit trips. Position feedback is accepted through an IndraDyn Hiperface/EnDat 2.1/2.2 encoder interface, enabling high-resolution motor commutation. The supply stage can operate in infeeding or fed mode, supporting common DC bus configurations. This combination supports accurate feedback processing together with rapid torque shutdown during coordinated motion.

Communication Interface
SERCOS III master (cross communication)
Control Section Design Type
ADVANCED
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
13 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Not equipped
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 110...230 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'ADVANCED' (A)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Safety Interface
STO (Safe Torque Off)
  • HCS011EW0013A02ACCECNNL3NNFW
  • HCS01 1E W0013 A 02 A CC EC NN L3 NN FW
  • hcs01.1e-w0009-a-02-a-cc-ec-pb-l3-nn-fw
  • HCS1.1E-W0013-A-02-A-CC-EC-NN-L3-NN-FW

Frequently Asked Questions about HCS01.1E-W0013-A-02-A-CC-EC-NN-L3-NN-FW:

Q: What type of communication interface is available on the HCS01.1E-W0013-A-02-A-CC-EC-NN-L3-NN-FW drive controller?

A: The HCS01.1E-W0013-A-02-A-CC-EC-NN-L3-NN-FW supports cross communication with a SERCOS III master interface.

Q: How is the HCS01.1E-W0013-A-02-A-CC-EC-NN-L3-NN-FW cooled?

A: This drive controller provides internal air cooling through an integrated blower.

Q: What is the maximum peak current for the HCS01.1E-W0013-A-02-A-CC-EC-NN-L3-NN-FW IndraDrive controller?

A: The HCS01.1E-W0013-A-02-A-CC-EC-NN-L3-NN-FW can deliver a peak device current of 13 A.

Q: What mains voltage does the HCS01.1E-W0013-A-02-A-CC-EC-NN-L3-NN-FW controller accept?

A: This model supports a main voltage range of 3 x AC 110 to 230 V with a ±10% tolerance.

Q: What safety interface is included on the Bosch Rexroth HCS01.1E-W0013-A-02-A-CC-EC-NN-L3-NN-FW?

A: The HCS01.1E-W0013-A-02-A-CC-EC-NN-L3-NN-FW features the STO (Safe Torque Off) safety interface.


Internal Product Review

  • ‘‘The HCS01.1E-W0013-A-02-A-CC-EC-NN-L3-NN-FW is an HCS drive controller with SERCOS III master communication and an ADVANCED control section. Internal air cooling through an integrated blower and 13 A peak current support stable thermal behavior and capable transient performance. STO Safe Torque Off is a strong finishing feature for safety-conscious automation applications.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo