The Bosch Rexroth Indramat HCS01.1E-W0013-A-02-A-CC-EC-EM-S5-NN-FW is part of the HCS IndraDrive Controllers series. This drive controller features a device peak current of 13 Amps and operates on a mains voltage of 3 x AC 110 to 230 Volts. It comes with an IP20 rating and uses integrated air cooling.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The HCS01.1E-W0013-A-02-A-CC-EC-EM-S5-NN-FW is a Bosch Rexroth Indramat drive controller from the HCS IndraDrive Controllers series, intended for compact single-axis automation. It rectifies three-phase supply power and feeds a regulated DC link to the attached motor while receiving motion commands from the control section mounted above it. In packaging, assembly, and handling lines, the unit supplies controlled current so the mechanical axis can follow programmed velocity, position, or torque profiles with closed-loop precision. Because the control section sits above the power unit, signal handling and power conversion stay in a compact stacked arrangement that fits small control cabinets. The regulated output also helps the motor respond smoothly to changing load demands during indexing and positioning tasks.
The rated supply is 3 x AC 110…230 V ±10%, which supports connection to common industrial mains without an autotransformer. During acceleration, it can deliver a peak phase current of 13 A before returning to continuous limits. Command and diagnostic traffic move over a SERCOS III master interface that permits synchronized cross-communication among multiple drives. The installed control section is the ADVANCED type, design version 1, and it adds expanded internal processing together with nonvolatile parameter storage. Environmental protection is limited to IP20, so the unit must be installed inside a protective cabinet or enclosure. Direct exposure to dust or moisture is not suitable without additional protection.
Heat is removed by internal air cooling produced by an integrated blower, which avoids external ductwork and preserves the 65 mm HCS01 footprint. For motor feedback, the primary port supports Hiperface/EnDat 2.1/2.2 encoders, while a second connector provides encoder emulation so external control hardware can still receive position information. This arrangement supports both modern absolute encoder connections and legacy position signal requirements. The power section supports infeeding and fed operation on the shared DC bus, allowing it to source or absorb energy during axis movement. That shared bus behavior is useful during normal acceleration and braking cycles, especially where regenerative energy moves between connected axes.
Frequently Asked Questions about HCS01.1E-W0013-A-02-A-CC-EC-EM-S5-NN-FW:
Q: What type of communication interface is available on the HCS01.1E-W0013-A-02-A-CC-EC-EM-S5-NN-FW drive controller?
A: The HCS01.1E-W0013-A-02-A-CC-EC-EM-S5-NN-FW supports SERCOS III master interface with cross communication capability.
Q: How is the HCS01.1E-W0013-A-02-A-CC-EC-EM-S5-NN-FW cooled during operation?
A: This drive controller uses internal air cooling provided by an integrated blower.
Q: What is the peak current capability of the HCS01.1E-W0013-A-02-A-CC-EC-EM-S5-NN-FW?
A: The drive supports a peak device current rating of 13 A.
Q: What is the mains voltage requirement for the HCS01.1E-W0013-A-02-A-CC-EC-EM-S5-NN-FW?
A: The main supply voltage range for this model is 3-phase AC 110 to 230 V with a ±10% tolerance.
Q: Which encoder interfaces are supported by the main interface of the HCS01.1E-W0013-A-02-A-CC-EC-EM-S5-NN-FW?
A: This unit provides encoder support via IndraDyn Hiperface and EnDat 2.1/2.2 on its primary interface.