The Bosch Rexroth Indramat HCS01.1E-W0013-A-02-A-CC-EC-EC-L4-NN-FW is a drive controller from the HCS IndraDrive Controllers series. It features an ADVANCED control section design and operates with a device peak current of 13 Amps. The unit is equipped with SERCOS III master cross communication and supports STO and SBC safety interfaces, with an internal air cooling method through an integrated blower.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0013-A-02-A-CC-EC-EC-L4-NN-FW is a compact drive controller manufactured by Bosch Rexroth Indramat and assigned to the HCS IndraDrive Controllers series. Within an automation cell, this unit supplies regulated current to synchronous or asynchronous motors and exchanges motion data with the machine control system for single-axis operation. Its architecture combines power electronics, communication, and protective functions in one housing, which helps reduce cabinet wiring and keeps the installation layout compact. This arrangement is suited to automated equipment that requires motor control, feedback handling, and coordinated command exchange from one controller.

At the fieldbus layer, the controller carries an integrated SERCOS III master, permitting deterministic cross-communication between drives and enabling cycle-synchronous motion sequencing. It is paired with a control section classified as ADVANCED, which provides the processing capacity needed for local interpolation and safety-related functions inside the drive system. The power stage accepts a three-phase 110–230 V AC mains input and can deliver a device peak current of 13 A to the connected motor during acceleration or changing load conditions. Thermal energy is removed by an internal blower, and the housing has an IP20 rating for installation inside an enclosed cabinet.

Functional safety is provided through dual channels: the hardware implements STO to eliminate torque during emergency conditions and SBC to control an external brake through the same safety logic. Two identical feedback ports support IndraDyn Hiperface/EnDat 2.2 encoders, allowing either redundant position capture or the connection of both motor and external axis feedback devices. The power supply topology supports infeeding and bus-fed operation, so the unit can receive energy from a common DC bus or supply neighboring inverters in multi-axis groups. Design version 1 and the lack of optional add-ons keep the configuration straightforward and leave the controller focused on its core drive and safety functions.

Communication Interface
SERCOS III master (cross communication)
Control Section Design Type
ADVANCED
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
13 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 110...230 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'ADVANCED' (A)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Safety Interface
STO (Safe Torque Off) and SBC (Safe Brake Control)
  • HCS011EW0013A02ACCECECL4NNFW
  • HCS01 1E W0013 A 02 A CC EC EC L4 NN FW
  • hcs01.1e-w0009-a-02-a-cc-ec-et-l4-nn-fw
  • HCS1.1E-W0013-A-02-A-CC-EC-EC-L4-NN-FW

Frequently Asked Questions about HCS01.1E-W0013-A-02-A-CC-EC-EC-L4-NN-FW:

Q: What communication interface does the HCS01.1E-W0013-A-02-A-CC-EC-EC-L4-NN-FW controller use?

A: The HCS01.1E-W0013-A-02-A-CC-EC-EC-L4-NN-FW controller supports SERCOS III master cross communication interface for connectivity with compatible automation equipment.

Q: What is the peak current capability of the HCS01.1E-W0013-A-02-A-CC-EC-EC-L4-NN-FW?

A: This model provides a device peak current of 13 A, suitable for moderate power drive applications.

Q: How is the HCS01.1E-W0013-A-02-A-CC-EC-EC-L4-NN-FW controller cooled?

A: Cooling is provided by an internal air system using an integrated blower for reliable thermal management.

Q: What safety interface features are provided with this HCS IndraDrive Controller?

A: The safety interface includes STO (Safe Torque Off) and SBC (Safe Brake Control), supporting enhanced operational safety.

Q: What mains voltage range does the HCS01.1E-W0013-A-02-A-CC-EC-EC-L4-NN-FW support?

A: This drive controller operates on a mains voltage of 3 x AC 110 to 230 V with a tolerance of ±10%.


Internal Product Review

  • ‘‘The HCS01.1E-W0013-A-02-A-CC-EC-EC-L4-NN-FW is an HCS drive controller with SERCOS III master communication and an ADVANCED control section for precise automation tasks. Internal air cooling through an integrated blower and IP20 protection support dependable cabinet integration. STO and SBC safety functions make the controller a strong choice for safety-conscious drive systems.’’