4.95 based on 202 reviews

🙶 Great service, they have the parts i needed in stock. 🙷

HCS01.1E-W0013-A-02-A-CC-EC-CN-NN-NN-FW Bosch Rexroth Indramat

MPN: R911374080

No Tariffs On US Orders
  • Rated 4.6 (15 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0013-A-02-A-CC-EC-CN-NN-NN-FW is a drive controller in the HCS IndraDrive Controllers series. It features a SERCOS III master communication interface and an internal air cooling method with an integrated blower. The device supports a peak current of 13 Amps, operates at a mains voltage of 3 x AC 110 to 230 Volts, and has an IP20 rating.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0013-A-02-A-CC-EC-CN-NN-NN-FW is a drive controller produced by Bosch Rexroth Indramat for the HCS IndraDrive Controllers series. It converts supply power into regulated three-phase outputs and processes motion commands to run servo or induction motors used in automated assembly lines, packaging stations, and material-handling axes. This allows the controller to regulate acceleration, speed, and torque as machine demand changes during positioning and transfer tasks. The housing is sized for the HCS01 line and is intended for installation inside electrical enclosures where cabinet space is limited. Its compact format suits cabinets where multiple drive components must be mounted close together. The unit does not include an integrated safety interface, so any required safety function must be provided externally.

Input power spans 3 x AC 110...230 V ±10%, letting the controller run on low-voltage three-phase grids commonly used in compact automation systems. Cooling is provided by internal air cooling through an integrated blower, which eliminates the need for external ducting and keeps the enclosure layout straightforward. The inverter delivers up to 13 A of peak motor current, and the housing is protected to IP20 for installation inside a control cabinet. Motion commands, status words, and cross-communication are carried on a SERCOS III master with cross communication interface. This communication path supports cyclic command exchange between the drive and the higher-level control system.

The unit incorporates the ADVANCED control section in design version 1, supporting the functions assigned to this controller configuration. Motor feedback connects through the multifunction IndraDyn Hiperface/EnDat 2.1/2.2 encoder interface, giving the controller access to position data from compatible feedback devices. PLCs can access parameters through the auxiliary CANopen bus for additional communication tasks. The drive uses an infeeding and fed power concept, so several drives can share one DC bus and return excess energy to the mains during operation instead of dissipating it locally. Shared DC bus operation can reduce the need for separate power conversion on each connected axis.

Communication Interface
SERCOS III master (cross communication)
Control Section Design Type
ADVANCED
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
13 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
CANopen
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 110...230 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'ADVANCED' (A)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Safety Interface
Not equipped
  • HCS011EW0013A02ACCECCNNNNNFW
  • HCS01 1E W0013 A 02 A CC EC CN NN NN FW
  • hcs01.1e-w0009-a-02-a-cc-ec-em-l3-nn-fw
  • HCS1.1E-W0013-A-02-A-CC-EC-CN-NN-NN-FW

Frequently Asked Questions about HCS01.1E-W0013-A-02-A-CC-EC-CN-NN-NN-FW:

Q: What type of communication interface does the HCS01.1E-W0013-A-02-A-CC-EC-CN-NN-NN-FW drive controller support?

A: The HCS01.1E-W0013-A-02-A-CC-EC-CN-NN-NN-FW controller supports SERCOS III master communication with cross communication capabilities.

Q: What is the control section design type of the HCS01.1E-W0013-A-02-A-CC-EC-CN-NN-NN-FW?

A: This controller is designed with an ADVANCED control section type and must be paired accordingly.

Q: How is the HCS01.1E-W0013-A-02-A-CC-EC-CN-NN-NN-FW cooled?

A: Internal air cooling using an integrated blower is provided for this drive controller.

Q: What is the maximum peak current supported by the HCS01.1E-W0013-A-02-A-CC-EC-CN-NN-NN-FW?

A: The device operates at a peak current of 13 A, which determines the maximum load it can handle.

Q: What mains voltage is required to operate the HCS01.1E-W0013-A-02-A-CC-EC-CN-NN-NN-FW?

A: This model is rated for mains supply voltages of 3 x AC 110 to 230 V with a variance of ±10%.


Internal Product Review

  • ‘‘The HCS01.1E-W0013-A-02-A-CC-EC-CN-NN-NN-FW is an HCS Drive Controller with an ADVANCED control section design and internal air cooling through an integrated blower. SERCOS III master cross communication and CANopen support make the unit especially appealing for coordinated motion and network integration. A 13 A peak current rating with IP20 protection gives the controller strong cabinet-ready performance.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo