The Bosch Rexroth Indramat HCS01.1E-W0009-A-03-B-ET-EC-EC-NN-NN-FW is a drive controller from the HCS IndraDrive Controllers series with a peak current of 9 Amps and IP20 protection. This model features MultiEthernet communication, integrated air cooling via an internal blower, and encoder interfaces compatible with IndraDyn Hiperface and EnDat 2.1/2.2.

Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0009-A-03-B-ET-EC-EC-NN-NN-FW is a drive controller manufactured by Bosch Rexroth Indramat within the HCS IndraDrive Controllers series. The unit supplies regulated three-phase power and processes position feedback for servo and induction motors, allowing coordinated motion tasks in packaging, printing, and handling equipment. By combining a power stage with an exchangeable control section, the product brings axis-level regulation and network connectivity directly into the automation cabinet. It is intended for cabinet-mounted motion systems that need compact integration of motor control, feedback handling, and communication in a single drive platform.

This controller accepts a mains range of 3 x AC 200...500 V ±10%, so it can connect to many industrial power systems without an autotransformer. Its peak output of 9 A is the maximum motor current available for acceleration or short overload periods before protective functions respond. Thermal management is handled by internal air cooling, which uses an integrated blower to move heat away from the power electronics. The enclosure has an IP20 rating for finger-safe protection inside a closed cabinet, so it should be installed in a clean, dry location. A built-in MultiEthernet interface supports common Ethernet-based protocols and helps the drive fit different control networks.

The control hardware is supplied in the BASIC configuration for standard motion functions. The unit uses design version 1 for this controller build. Its power connection is Infeeding / Feeding, allowing the drive either to supply energy to the DC bus or to draw energy from it during operation. Dual feedback ports accept Encoder IndraDyn Hiperface/EnDat 2.1/2.2 signals, enabling precise position control with Rexroth and third-party motors. This layout supports mixed motor installations without requiring additional interface cards.

Communication Interface
MultiEthernet
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
9 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Safety Interface
Not equipped

Frequently Asked Questions about HCS01.1E-W0009-A-03-B-ET-EC-EC-NN-NN-FW:

Q: What communication interface is supported by the HCS01.1E-W0009-A-03-B-ET-EC-EC-NN-NN-FW drive controller?

A: The HCS01.1E-W0009-A-03-B-ET-EC-EC-NN-NN-FW features MultiEthernet communication for flexible connectivity options.

Q: What is the peak current capacity of the HCS01.1E-W0009-A-03-B-ET-EC-EC-NN-NN-FW?

A: This drive controller has a device peak current rating of 9 A, supporting medium-load applications.

Q: How is the HCS01.1E-W0009-A-03-B-ET-EC-EC-NN-NN-FW drive controller cooled?

A: The cooling system relies on internal air flow using an integrated blower.

Q: What types of encoder interfaces does the HCS01.1E-W0009-A-03-B-ET-EC-EC-NN-NN-FW support?

A: The product offers encoder interfaces compatible with IndraDyn Hiperface and EnDat 2.1/2.2.

Q: What level of environmental protection does the HCS01.1E-W0009-A-03-B-ET-EC-EC-NN-NN-FW offer?

A: This drive controller has an IP20 rating, which means it provides limited protection against solid objects and no protection against liquids.


Internal Product Review

  • ‘‘The HCS01.1E-W0009-A-03-B-ET-EC-EC-NN-NN-FW is an HCS drive controller with BASIC control section architecture and internal air cooling through an integrated blower. MultiEthernet communication and dual IndraDyn Hiperface/EnDat 2.1/2.2 encoder interfaces support clean network integration and dependable feedback handling. A 9 A peak current rating across 3 x AC 200...500 V input makes the unit a strong fit for compact IndraDrive installations.’’