HCS01.1E-W0009-A-02-E-S3-EC-NN-NN-AA-FW Bosch Rexroth Indramat
MPN: R911331044
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat HCS01.1E-W0009-A-02-E-S3-EC-NN-NN-AA-FW is an HCS Drive Controller in the HCS IndraDrive Controllers series. It features a SERCOS III communication interface, an ECONOMY control section, and an air cooling method through an integrated blower. The drive controller supports a device peak current of 9 Amps, has an IP20 rating, and operates on 3-phase AC voltage from 110 to 230 Volts.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The HCS01.1E-W0009-A-02-E-S3-EC-NN-NN-AA-FW drive controller is produced by Bosch Rexroth Indramat for the HCS IndraDrive Controllers series. It converts line power, executes motion commands, and drives synchronous or asynchronous motors in automated assembly cells, packaging stations, and material-handling axes. By closing the current, speed, and position loops in one housing, the unit delivers the rapid response and accuracy required for modern industrial automation. This integrated control structure helps the axis respond consistently during starting, speed changes, and position correction under varying mechanical loads.
The controller accepts a three-phase supply of 3 × AC 110…230 V ±10%, allowing direct connection to common low-voltage plant networks. Heat from the power semiconductors is removed by internal blower cooling, so the unit can manage thermal buildup inside a protected cabinet. During acceleration, it can supply up to 9 A of peak current, giving short-term torque reserve for temporary load increases. Fieldbus traffic is handled through SERCOS III, providing deterministic real-time exchange for coordinated multi-axis operation. The installed control section is the ECONOMY variant, which suits applications that need core motion control functions without added interface complexity.
Within the HCS01 line, the power stage uses the Infeeding / Feeded topology, which allows the device to share or return DC-bus energy within the drive system. Its housing is rated IP20, which protects against finger contact and is intended for installation inside a closed electrical enclosure rather than direct exposure on the machine. Feedback is accepted through Encoder IndraDyn Hiperface/EnDat 2.1/2.2, allowing compatibility with common motor feedback systems used for precise speed and position control. A second feedback channel and the safety interface are omitted to simplify the configuration. Manufactured as design version 1, the hardware is supplied without resident application software.
Frequently Asked Questions about HCS01.1E-W0009-A-02-E-S3-EC-NN-NN-AA-FW:
Q: What communication interface is available on the HCS01.1E-W0009-A-02-E-S3-EC-NN-NN-AA-FW?
A: This controller features a SERCOS III communication interface for network connectivity.
Q: How is the HCS01.1E-W0009-A-02-E-S3-EC-NN-NN-AA-FW cooled?
A: The device operates with internal air cooling using an integrated blower for thermal management.
Q: What is the peak current rating of the HCS01.1E-W0009-A-02-E-S3-EC-NN-NN-AA-FW?
A: The peak current for this controller is rated at 9 A during operation.
Q: What mains voltage supply is supported by the HCS01.1E-W0009-A-02-E-S3-EC-NN-NN-AA-FW?
A: This model is designed for a mains voltage supply of 3-phase AC 110 to 230 V with a ±10% tolerance.
Q: What is the IP rating of the HCS01.1E-W0009-A-02-E-S3-EC-NN-NN-AA-FW?
A: The protection class for this controller is IP20, which means it provides basic protection against solid objects but no protection against liquids.