4.95 based on 202 reviews

🙶 Easy to navigate website and quick responses from support. Additionally, pretty fast shipping. Our mainte... 🙷

HCS01.1E-W0009-A-02-E-S3-EC-NN-L4-AA-FW Bosch Rexroth Indramat

MPN: R911333493

No Tariffs On US Orders
  • Rated 4.4 (39 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0009-A-02-E-S3-EC-NN-L4-AA-FW is a drive controller from the HCS IndraDrive Controllers series. It features a SERCOS III communication interface, device peak current of 9 A, and supports mains voltages from 110 to 230 V AC. The controller offers STO and SBC safety interfaces and uses internal air cooling through an integrated blower, with an IP20 rating.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0009-A-02-E-S3-EC-NN-L4-AA-FW is a drive controller produced by Bosch Rexroth Indramat within the HCS IndraDrive Controllers series. It belongs to the HCS01 line and is supplied as design version 1. The unit converts incoming three-phase supply power into regulated motor current for servo axes in industrial automation cells, conveyors, and handling systems. It is intended for compact motion applications where the drive must support coordinated speed, torque, and position control within a machine system.

The controller accepts a mains window of 3 × AC 110–230 V ±10% and can deliver up to 9 A of peak output, allowing it to operate small to medium IndraDyn motors. This voltage range supports use on low-voltage three-phase supplies commonly found in compact industrial equipment. Command and diagnostic data move over SERCOS III, while the installed control section follows the ECONOMY profile for standard motion tasks. Thermal energy is removed by internal air cooling through an integrated blower. The power section is arranged so regenerated braking energy can be returned to the DC link during deceleration when compatible system components are used.

For cabinet integration, the housing carries an IP20 ingress rating, so it must be mounted in an enclosed panel rather than in an open machine area. Motion stop and brake release functions are handled through the dual-channel safety inputs STO and SBC, supporting torque shutdown and controlled brake actuation. High-resolution position data reach the drive through the multifunction encoder port that supports Encoder IndraDyn Hiperface/EnDat 2.1/2.2. Support for these feedback formats allows the controller to work with multiple compatible motor encoder systems. A second feedback socket is left vacant, which allows operation without a redundant sensor channel when the application does not require one.

Communication Interface
SERCOS III
Control Section Design Type
ECONOMY
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
9 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Not equipped
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 110...230 V ±10%
Pairing Note
Paired with Control Section Design 'ECONOMY' (E)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Safety Interface
STO (Safe Torque Off) and SBC (Safe Brake Control)
  • HCS011EW0009A02ES3ECNNL4AAFW
  • HCS01 1E W0009 A 02 E S3 EC NN L4 AA FW
  • hcs01.1e-w0008_a-03-b-et-ec-nn-nn-nn-fw
  • HCS1.1E-W0009-A-02-E-S3-EC-NN-L4-AA-FW

Frequently Asked Questions about HCS01.1E-W0009-A-02-E-S3-EC-NN-L4-AA-FW:

Q: Which communication protocol is available on the HCS01.1E-W0009-A-02-E-S3-EC-NN-L4-AA-FW drive controller?

A: This model supports SERCOS III as its primary communication interface.

Q: What is the cooling method used on the HCS01.1E-W0009-A-02-E-S3-EC-NN-L4-AA-FW?

A: The device achieves cooling using an integrated internal blower.

Q: What is the device peak current of the HCS01.1E-W0009-A-02-E-S3-EC-NN-L4-AA-FW controller?

A: The HCS01.1E-W0009-A-02-E-S3-EC-NN-L4-AA-FW has a peak current rating of 9 A.

Q: What level of ingress protection does the HCS01.1E-W0009-A-02-E-S3-EC-NN-L4-AA-FW provide?

A: This controller features an IP20 protection rating, allowing basic protection against solid objects.

Q: What safety functions are integrated into the HCS01.1E-W0009-A-02-E-S3-EC-NN-L4-AA-FW drive controller?

A: The safety interface includes both Safe Torque Off (STO) and Safe Brake Control (SBC) functions.


Internal Product Review

  • ‘‘The HCS01.1E-W0009-A-02-E-S3-EC-NN-L4-AA-FW is an HCS drive controller configured with SERCOS III communication and an ECONOMY control section. Internal blower cooling and 9 A peak current give the unit solid thermal behavior and capable dynamic response. STO and SBC safety functions are a strong advantage for machine integration.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo