The Bosch Rexroth Indramat HCS01.1E-W0009-A-02-B-ET-EC-PB-NN-AA-FW is an HCS Drive Controller with a device peak current of 9 Amps and MultiEthernet communication interface. Part of the HCS IndraDrive Controllers series, this controller features an internal air cooling method with an integrated blower and supports both PROFIBUS and IndraDyn Hiperface/EnDat 2.1/2.2 encoder interfaces. It operates with a mains voltage of 3 x AC 110 to 230 Volts and has an IP20 rating.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0009-A-02-B-ET-EC-PB-NN-AA-FW is a compact drive controller produced by Bosch Rexroth Indramat within the HCS IndraDrive Controllers series. Designed for cabinet installation, the unit acts as the power and control interface between a low-voltage three-phase supply and connected servomotors, allowing closed-loop motion tasks in automated machinery. By integrating power electronics, diagnostic logic, and network connections in one housing, it supports axis control in packaging, handling, and general factory automation.

For system communication, the controller includes a MultiEthernet port that supports several real-time Ethernet protocols without additional hardware. The enclosure carries a protection rating of IP20, which allows touch-safe operation but requires mounting inside a protected cabinet. Power is accepted from a three-phase mains supply of 3 x AC 110...230 V ±10%, making the device suitable for American and other low-voltage grids. Its internal power stage can deliver up to 9 A of peak current to the motor, which affects allowable acceleration torque and drive sizing. Axis feedback plugs into Interface 1, which is compatible with IndraDyn Hiperface/EnDat 2.1/2.2 encoders and gives the controller access to absolute position and temperature data for precise vector control.

Fieldbus integration on Interface 2 is realized through PROFIBUS, enabling deterministic exchange of setpoints and status with PLCs that already use this protocol. Thermal management relies on internal air cooling through an integrated blower, so the fan forces cabinet air across the heat sinks without external coolant lines. The power section pairs with a control section identified as BASIC, providing standard motion functions without integrated safety-related options. The unit also supports common DC bus operation, allowing shared energy flow within a linked drive system.

Communication Interface
MultiEthernet
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
9 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
PROFIBUS
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 110...230 V ±10%
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Safety Interface
Not equipped
  • HCS011EW0009A02BETECPBNNAAFW
  • HCS01 1E W0009 A 02 B ET EC PB NN AA FW
  • hcs01.1e-w0008-a-03-e-s3-ec-nn-l4-nn-fw
  • HCS1.1E-W0009-A-02-B-ET-EC-PB-NN-AA-FW

Frequently Asked Questions about HCS01.1E-W0009-A-02-B-ET-EC-PB-NN-AA-FW:

Q: What communication interface does the HCS01.1E-W0009-A-02-B-ET-EC-PB-NN-AA-FW controller use?

A: The HCS01.1E-W0009-A-02-B-ET-EC-PB-NN-AA-FW supports MultiEthernet as its primary communication interface for flexible networking.

Q: What cooling method does the HCS01.1E-W0009-A-02-B-ET-EC-PB-NN-AA-FW use?

A: This model is cooled internally with an integrated blower for efficient heat dissipation.

Q: What mains voltage range is supported by the HCS01.1E-W0009-A-02-B-ET-EC-PB-NN-AA-FW controller?

A: The drive controller operates with a mains voltage of 3 x AC 110 to 230 V ±10%.

Q: What is the device peak current for the HCS01.1E-W0009-A-02-B-ET-EC-PB-NN-AA-FW?

A: A peak output current of 9 A is available on this device.

Q: What level of protection does the IP20 rating provide for the HCS01.1E-W0009-A-02-B-ET-EC-PB-NN-AA-FW controller?

A: The IP20 rating means this controller offers protection against solid objects larger than 12.5 mm but no protection against liquids.


Internal Product Review

  • ‘‘The HCS01.1E-W0009-A-02-B-ET-EC-PB-NN-AA-FW is a Bosch Rexroth Indramat HCS drive controller with MultiEthernet communication and a PROFIBUS interface. Internal blower cooling and 3 x AC 110...230 V mains input support dependable operation and flexible machine integration. A 9 A peak current and IP20 protection make this controller a strong choice for industrial drive applications.’’