4.95 based on 202 reviews

🙶 Excellent to work with and they stand behind their work. I would highly recommend them. 🙷

HCS01.1E-W0009-A-02-B-ET-EC-EP-NN-NN-FW Bosch Rexroth Indramat

MPN: R911373128

No Tariffs On US Orders
  • Rated 4.5 (63 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
In-Stock, Ships 3-5 Days

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0009-A-02-B-ET-EC-EP-NN-NN-FW is part of the HCS IndraDrive Controllers series. This drive controller features a MultiEthernet communication interface and supports encoder connections including IndraDyn Hiperface and EnDat 2.1/2.2. It has a peak current of 9 Amps, operates at mains voltages of 110 to 230 Volts AC, and uses internal air cooling through an integrated blower.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0009-A-02-B-ET-EC-EP-NN-NN-FW is a compact drive controller produced by Bosch Rexroth Indramat within the HCS IndraDrive Controllers series. Intended for servo and induction motor axes in the low-kilowatt range, it serves as the power and control core that processes drive commands and energizes the connected motor stages. By integrating the power electronics, feedback interface, and fieldbus communication into one enclosure, the unit supports tightly synchronized motion in packaging machines, handling stations, and other automated assemblies. It can serve as the main motion component for compact axes where cabinet space is limited but coordinated control is still required.

For networked installations, the controller offers a MultiEthernet port that can be configured for EtherNet/IP, PROFINET, or EtherCAT without additional hardware. The mounted control section follows the BASIC design, so parameter processing and control functions are handled within the drive. Heat generated by switching devices is removed through internal air cooling, using an integrated blower that draws cabinet air across the heat sink and eliminates external ducting. Power stage capability reaches 9 A peak current, which is suitable for small dynamic axes, and the housing carries an IP20 rating for protected cabinet mounting away from direct liquid or dust exposure.

The supply side accepts 3 × AC 110–230 V ±10%, allowing the same hardware to be used on three-phase low-voltage mains in different regions. Feedback wiring terminates on the first interface slot that supports a Hiperface/EnDat 2.1/2.2 encoder input, enabling absolute position monitoring with IndraDyn motors or compatible third-party devices. Energy exchange with the DC bus is handled by an infeeding and regenerative power supply, so braking energy can be returned to the supply or shared on the DC bus. The unit provides no safety interface, so safety functions must be handled by external hardware or higher-level control equipment.

Communication Interface
MultiEthernet
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
9 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 110...230 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Safety Interface
Not equipped
  • HCS011EW0009A02BETECEPNNNNFW
  • HCS01 1E W0009 A 02 B ET EC EP NN NN FW
  • hcs01.1e-w0008-a-03-b-et-ec-nn-s5-nn-aw
  • HCS1.1E-W0009-A-02-B-ET-EC-EP-NN-NN-FW

Frequently Asked Questions about HCS01.1E-W0009-A-02-B-ET-EC-EP-NN-NN-FW:

Q: What type of communication interface does the HCS01.1E-W0009-A-02-B-ET-EC-EP-NN-NN-FW controller use?

A: The HCS01.1E-W0009-A-02-B-ET-EC-EP-NN-NN-FW features a MultiEthernet communication interface for flexible network connectivity.

Q: How is the HCS01.1E-W0009-A-02-B-ET-EC-EP-NN-NN-FW cooled?

A: This drive controller uses an integrated blower for internal air cooling.

Q: What is the peak current supported by the HCS01.1E-W0009-A-02-B-ET-EC-EP-NN-NN-FW controller?

A: The peak device current for this model is rated at 9 A.

Q: What is the IP rating of the HCS01.1E-W0009-A-02-B-ET-EC-EP-NN-NN-FW drive controller?

A: The HCS01.1E-W0009-A-02-B-ET-EC-EP-NN-NN-FW has an IP20 rating for environmental protection.

Q: What is the supported mains voltage range for the HCS01.1E-W0009-A-02-B-ET-EC-EP-NN-NN-FW?

A: This controller operates on a mains voltage supply of 3 x AC 110 to 230 V (±10%).


Internal Product Review

  • ‘‘The HCS01.1E-W0009-A-02-B-ET-EC-EP-NN-NN-FW is an HCS drive controller with a BASIC control section and MultiEthernet communication. Internal blower cooling and IP20 protection make the controller a strong fit for clean cabinet installations. A 9 A peak current rating gives the platform solid dynamic capability for compact IndraDrive systems.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo