4.95 based on 202 reviews

🙶 Easy to navigate website and quick responses from support. Additionally, pretty fast shipping. Our mainte... 🙷

HCS01.1E-W0009-A-02-B-ET-EC-EP-L3-NN-FW Bosch Rexroth Indramat

MPN: R911379338

No Tariffs On US Orders
  • Rated 4.6 (66 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Current response time:
4 Minutes 24 Seconds

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0009-A-02-B-ET-EC-EP-L3-NN-FW is part of the HCS IndraDrive Controllers series and functions as an HCS drive controller. It features a device peak current of 9 Amps, operates on a mains voltage of 3 x AC 110 to 230 Volts, and uses IP20 protection. The controller provides a MultiEthernet communication interface, supports encoder interfaces like IndraDyn Hiperface and EnDat, and offers STO safety functionality.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0009-A-02-B-ET-EC-EP-L3-NN-FW drive controller is produced by Bosch Rexroth Indramat within the HCS IndraDrive Controllers series. It forms the power section of compact single-axis servo systems, supplying regulated energy to connected motors and executing motion commands received from the machine control. By combining power conversion, current regulation, and integrated protective functions, the unit supports precise closed-loop speed and torque control in packaging, handling, and printing equipment. Its compact design also helps simplify cabinet integration where space is limited.

Its communication stack is based on MultiEthernet, allowing the same hardware to exchange real-time data over EtherNet/IP, PROFINET, or EtherCAT without additional option cards. The housing carries an IP20 enclosure rating, so it must be installed inside a cabinet that protects it from accidental contact and airborne contamination. The power section accepts a three-phase supply of 3 x AC 110-230 V ±10%, making the device suitable for low-voltage factory grids. During acceleration or braking, the converter can deliver up to 9 A of peak output current to the motor windings. Feedback is handled through the Encoder IndraDyn Hiperface/EnDat 2.1/2.2 interface, which supports single-turn and multi-turn encoders with electronic nameplate data for automatic parameter loading.

The paired control section is categorized as BASIC, so it is intended for standard point-to-point positioning rather than advanced robotics or CNC functions. Thermal management relies on internal air cooling provided by an integrated blower, so cabinet airflow only needs to remove the discharged warm air. For functional safety, the hardware implements STO, which removes torque-producing energy within milliseconds when the external safety circuit is triggered. The module belongs to the HCS01 line, and it can operate as an infeeding axis or as a fed axis depending on the system topology. This allows common DC-bus sharing in compatible drive arrangements.

Communication Interface
MultiEthernet
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
9 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 110...230 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Safety Interface
STO (Safe Torque Off)
  • HCS011EW0009A02BETECEPL3NNFW
  • HCS01 1E W0009 A 02 B ET EC EP L3 NN FW
  • hcs01.1e-w0008-a-03-b-et-ec-nn-s4-nn-fw
  • HCS1.1E-W0009-A-02-B-ET-EC-EP-L3-NN-FW

Frequently Asked Questions about HCS01.1E-W0009-A-02-B-ET-EC-EP-L3-NN-FW:

Q: What communication interface is available on the HCS01.1E-W0009-A-02-B-ET-EC-EP-L3-NN-FW?

A: This drive controller uses MultiEthernet for communication with other devices and control systems.

Q: What is the maximum device peak current for the HCS01.1E-W0009-A-02-B-ET-EC-EP-L3-NN-FW?

A: The peak current supported by this model is 9 A, which determines its handling capacity during short-term load peaks.

Q: What level of ingress protection (IP rating) does the HCS01.1E-W0009-A-02-B-ET-EC-EP-L3-NN-FW have?

A: This controller offers an IP20 protection rating, making it suitable for indoor environments with limited exposure to dust and no protection against water.

Q: How is the HCS01.1E-W0009-A-02-B-ET-EC-EP-L3-NN-FW drive controller cooled?

A: The cooling method used is internal air cooling provided by an integrated blower unit.

Q: What is the supported mains voltage range for the HCS01.1E-W0009-A-02-B-ET-EC-EP-L3-NN-FW?

A: The mains voltage input for this controller is 3-phase AC, ranging from 110 to 230 V with a ±10% tolerance.


Internal Product Review

  • ‘‘The HCS01.1E-W0009-A-02-B-ET-EC-EP-L3-NN-FW is an HCS drive controller that stands out with MultiEthernet communication and a BASIC control section. Air cooling through an integrated blower and an STO safety interface make this unit a strong choice for dependable machine integration.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo