HCS01.1E-W0009-A-02-B-ET-EC-EM-S4-NN-FW Bosch Rexroth Indramat
MPN: R911380300
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat HCS01.1E-W0009-A-02-B-ET-EC-EM-S4-NN-FW is a drive controller from the HCS IndraDrive Controllers series. It supports MultiEthernet communication and operates with a device peak current of 9 Amps. The unit features an IP20 rating, uses air cooling through an integrated blower, and works with encoder interfaces like IndraDyn Hiperface and EnDat 2.1/2.2.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The HCS01.1E-W0009-A-02-B-ET-EC-EM-S4-NN-FW is a compact drive controller produced by Bosch Rexroth Indramat and belongs to the HCS IndraDrive Controllers series within the HCS01 line. Intended for cabinet installation in multi-axis machines, the unit conditions incoming AC power, interprets motion commands, and issues controlled current to a matched motor. In plant automation, it serves as the closed-loop actuator layer that translates PLC motion profiles into precise torque, velocity, and position at the load.
Electrical, thermal, and network details determine how the controller fits into a machine cabinet. Its communication backplane supports MultiEthernet networking, so the unit can attach to EtherNet/IP, PROFINET, or EtherCAT segments without extra hardware. The mains side tolerates 3 x AC 110…230 V ±10%, giving flexibility for low-voltage installations worldwide. Internally, an integrated blower provides internal air cooling, allowing cabinet mounting without external ducts. The power stage delivers a device peak current of 9 A, which supports short-term motor torque demand during acceleration. For protection against accidental contact, the housing is rated IP20, making enclosure placement mandatory.
The functional layer uses a BASIC control section and supports standard PLCopen command sets for routine motion tasks. Feedback wiring is simplified through dual encoder ports: Interface 1 accepts high-resolution Encoder IndraDyn Hiperface/EnDat 2.1 / 2.2 signals, and Interface 2 provides encoder emulation pulses for legacy drives. The power interface uses an Infeeding / Feeded topology, so the converter can share regenerated energy across a common DC bus. This arrangement allows one feedback channel to support closed-loop motor control while the emulation output can supply position signals to compatible external equipment.
Frequently Asked Questions about HCS01.1E-W0009-A-02-B-ET-EC-EM-S4-NN-FW:
Q: What type of communication interface is included on the HCS01.1E-W0009-A-02-B-ET-EC-EM-S4-NN-FW controller?
A: The HCS01.1E-W0009-A-02-B-ET-EC-EM-S4-NN-FW utilizes a MultiEthernet communication interface.
Q: What cooling method is implemented in the HCS01.1E-W0009-A-02-B-ET-EC-EM-S4-NN-FW model?
A: This drive controller operates with internal air cooling using an integrated blower.
Q: What is the peak current capacity of the HCS01.1E-W0009-A-02-B-ET-EC-EM-S4-NN-FW drive controller?
A: The device supports a peak current of 9 A during operation.
Q: What IP rating does the HCS01.1E-W0009-A-02-B-ET-EC-EM-S4-NN-FW drive controller have?
A: The HCS01.1E-W0009-A-02-B-ET-EC-EM-S4-NN-FW offers an IP20 protection rating.
Q: What mains voltage range does the HCS01.1E-W0009-A-02-B-ET-EC-EM-S4-NN-FW support?
A: It is compatible with mains voltage from 3 x AC 110 to 230 V with a tolerance of plus or minus 10%.