4.95 based on 202 reviews

🙶 Wake Ind. did a great job with very fast service getting us a motor driver to repair our critical robot sy... 🙷

HCS01.1E-W0009-A-02-B-ET-EC-EM-L3-NN-FW Bosch Rexroth Indramat

MPN: R911338641

No Tariffs On US Orders
  • Rated 4.5 (61 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0009-A-02-B-ET-EC-EM-L3-NN-FW is a drive controller in the HCS IndraDrive Controllers series. It features a MultiEthernet communication interface and supports encoder connections such as IndraDyn Hiperface, EnDat 2.1 and 2.2, and encoder emulation. The controller has an IP20 protection rating, operates at a mains voltage of 3 x AC 110 to 230 V, and has a peak current of 9 Amps.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0009-A-02-B-ET-EC-EM-L3-NN-FW is a compact drive controller built by Bosch Rexroth Indramat for the HCS IndraDrive Controllers series. It serves as the power and control stage between an IndraDrive power supply and servo or induction motors in automated machinery. Within an automation cell, the unit regulates current, monitors feedback, and executes motion commands delivered through a programmable logic controller. This role allows the drive to support coordinated motion in packaging equipment, handling systems, and other machines that depend on stable speed and position control.

A MultiEthernet interface allows the controller to work with several industrial Ethernet protocols without a hardware change. The control section uses the BASIC variant, which provides standard drive functions and parameter sets for general machine operation. Thermal management relies on internal air cooling provided by an integrated blower, so no external ductwork is required. The inverter delivers a peak phase current of 9 A, and it accepts a mains supply of 3 × AC 110–230 V ±10%, allowing operation on low-voltage three-phase systems used in different regions. The power section supports both infeeding and fed operation on a common DC bus, which is useful in multi-axis layouts where energy exchange occurs between connected drives. Design version 1 identifies the first mechanical release of the HCS01 line.

Channel one supports Encoder IndraDyn Hiperface/EnDat 2.1/2.2, allowing absolute position feedback from Rexroth and third-party motors. When downstream controllers require simulated feedback, the drive provides Encoder emulation signals that mirror incremental encoder output. Functional safety is handled by STO, which removes torque without external contactors. The unit uses an IP20 enclosure, so it is intended for installation in clean cabinets. Feedback compatibility and cabinet-only installation suit centralized control panels where wiring density and signal integrity matter.

Communication Interface
MultiEthernet
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
9 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Encoder emulation
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 110...230 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Safety Interface
STO (Safe Torque Off)
  • HCS011EW0009A02BETECEML3NNFW
  • HCS01 1E W0009 A 02 B ET EC EM L3 NN FW
  • hcs01.1e-w0008-a-03-b-et-ec-nn-l4-nn-fw
  • HCS1.1E-W0009-A-02-B-ET-EC-EM-L3-NN-FW

Frequently Asked Questions about HCS01.1E-W0009-A-02-B-ET-EC-EM-L3-NN-FW:

Q: What type of communication interface does the HCS01.1E-W0009-A-02-B-ET-EC-EM-L3-NN-FW provide?

A: The HCS01.1E-W0009-A-02-B-ET-EC-EM-L3-NN-FW is equipped with a MultiEthernet communication interface for flexible network integration.

Q: How is the HCS01.1E-W0009-A-02-B-ET-EC-EM-L3-NN-FW cooled?

A: This drive controller uses internal air cooling through an integrated blower for thermal management.

Q: What is the peak current capability of the HCS01.1E-W0009-A-02-B-ET-EC-EM-L3-NN-FW?

A: The peak device current for this model is rated at 9 A.

Q: Which encoder interfaces are supported by this drive controller?

A: The HCS01.1E-W0009-A-02-B-ET-EC-EM-L3-NN-FW supports encoder feedback via IndraDyn Hiperface and EnDat 2.1/2.2 encoders.

Q: What is the operating mains voltage range for the HCS01.1E-W0009-A-02-B-ET-EC-EM-L3-NN-FW?

A: This model operates on a mains voltage range of 3 x AC 110 to 230 V ±10%.


Internal Product Review

  • ‘‘The HCS01.1E-W0009-A-02-B-ET-EC-EM-L3-NN-FW is a Bosch Rexroth Indramat HCS drive controller with MultiEthernet communication and a BASIC control section. Internal blower cooling and STO safety support make the controller a highly practical choice for streamlined integration and dependable axis shutdown.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo