The Bosch Rexroth Indramat HCS01.1E-W0009-A-02-B-ET-EC-EC-L4-NN-FW is an HCS Drive Controller from the HCS IndraDrive Controllers series. It features MultiEthernet communication, an internal air cooling system, and an IP20 rating. This controller supports IndraDyn Hiperface and EnDat 2.1/2.2 encoder interfaces, offers a device peak current of 9 Amps, and includes STO and SBC safety interfaces.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The HCS01.1E-W0009-A-02-B-ET-EC-EC-L4-NN-FW is a compact drive controller produced by Bosch Rexroth Indramat for the HCS IndraDrive Controllers series. It serves as a modular axis unit for servo and induction motors in automated machinery and material-handling lines. In multi-axis cabinets, the controller is intended to provide regulated motor control while fitting into a compact installation space. The HCS01 designation places it within the smaller IndraDrive control platform for distributed cabinet layouts. Its role is to support controlled motor operation where coordinated axis response and cabinet integration are both important.
This controller accepts a three-phase supply of 3 × AC 110 to 230 V ±10%, allowing operation on low-voltage factory networks. During acceleration or load transients, it can deliver a device peak output of 9 A, which gives added current capacity for small and medium motor loads. Network traffic and parameter access are handled through the MultiEthernet port, so the unit can communicate with common industrial Ethernet systems without an added option card. The housing has an IP20 rating, so it must be installed inside a protected enclosure. That enclosure style also supports compact cabinet arrangements where direct exposure to dust or accidental contact must be limited. For safety functions, the drive includes STO and SBC, which remove torque and control the brake circuit when a safety command is issued.
Thermal management relies on internal air cooling through an integrated blower, so no external ducting is required at the drive body. The control section uses the BASIC variant, and both feedback channels support IndraDyn Hiperface and EnDat 2.1/2.2 encoders for closed-loop operation with absolute position capability. Using the same feedback support on both channels gives the unit flexibility when it is paired with compatible motor systems. Power is handled through an infeeding and regenerative supply stage, which matches common Rexroth power section arrangements. This layout suits applications that need compact installation, standard feedback connectivity, and integrated cooling within the control cabinet.
Frequently Asked Questions about HCS01.1E-W0009-A-02-B-ET-EC-EC-L4-NN-FW:
Q: What type of communication interface is available on the HCS01.1E-W0009-A-02-B-ET-EC-EC-L4-NN-FW controller?
A: The HCS01.1E-W0009-A-02-B-ET-EC-EC-L4-NN-FW offers MultiEthernet as its communication interface, supporting various industrial network protocols.
Q: What is the device peak current for the HCS01.1E-W0009-A-02-B-ET-EC-EC-L4-NN-FW?
A: The peak current rating for this drive controller is 9 A, allowing for brief periods of higher current draw during operation.
Q: What cooling method is used in the HCS01.1E-W0009-A-02-B-ET-EC-EC-L4-NN-FW drive controller?
A: Cooling is handled internally using an integrated blower, which draws air through the unit to maintain safe operating temperatures.
Q: Which safety interfaces are included on the HCS01.1E-W0009-A-02-B-ET-EC-EC-L4-NN-FW controller?
A: This drive controller includes STO (Safe Torque Off) and SBC (Safe Brake Control) safety interfaces for enhanced operational security.
Q: What mains voltage does the HCS01.1E-W0009-A-02-B-ET-EC-EC-L4-NN-FW require?
A: The mains voltage required for this model is 3-phase AC 110 to 230 V with a tolerance of ±10%.