4.95 based on 202 reviews

🙶 a+ fast delivery 🙷

HCS01.1E-W0009-A-02-B-ET-EC-DA-NN-NN-FW Bosch Rexroth Indramat

MPN: R911345396

No Tariffs On US Orders
  • Rated 4.6 (57 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0009-A-02-B-ET-EC-DA-NN-NN-FW is a drive controller from the HCS IndraDrive Controllers series. It features a MultiEthernet communication interface and supports encoder interfaces such as IndraDyn Hiperface and EnDat 2.1/2.2. The controller has a device peak current of 9 Amps, an IP20 rating, and uses internal air cooling through an integrated blower.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0009-A-02-B-ET-EC-DA-NN-NN-FW belongs to the HCS IndraDrive Controllers series produced by Bosch Rexroth Indramat. As an HCS drive controller, it coordinates power conversion and motion commands between the plant’s mains supply and connected servo or induction motors. This allows the unit to support closed-loop positioning and speed control in automated machinery and material-handling systems. In a typical axis system, it serves as the electronic link between incoming supply power, command data, and the motor response required by the machine. Its function is to regulate current and motor behavior so motion remains consistent during starts, stops, and speed changes.

For networked operation, the device supports MultiEthernet, allowing direct connection to EtherNet/IP, PROFINET, or EtherCAT lines without additional gateways. The power stage is rated for 3 × AC 110…230 V ±10%, which matches low-voltage three-phase supplies used in compact control cabinets. During acceleration or dynamic load peaks, the inverter can deliver up to 9 A. An internal blower provides internal air cooling, so cabinet airflow is not required as long as the inlet openings remain clear. The enclosure has an IP20 rating, and the front receptacle accepts an IndraDyn Hiperface/EnDat 2.1/2.2 encoder interface for high-resolution motor feedback. Because this protection level is intended for enclosed installation, the controller is normally mounted inside a closed control panel rather than on an exposed machine frame.

The control section uses the BASIC variant, and this pairing corresponds to design version 1 within the modular HCS01 arrangement. Power is transferred through a common DC bus, and the integrated supply supports infeed/feed operation, which allows the controller to supply or absorb bus energy when linked to other axes. This arrangement supports shared bus operation in multi-axis systems where one axis can return energy that another axis can use. No safety interface is fitted, so external STO or SS1 modules are required where those functions are needed. The operating feature set can be selected separately for the application without changing the hardware described here.

Communication Interface
MultiEthernet
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
9 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 110...230 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Safety Interface
Not equipped
  • HCS011EW0009A02BETECDANNNNFW
  • HCS01 1E W0009 A 02 B ET EC DA NN NN FW
  • hcs01.1e-w0008-a-03-b-et-ec-ep-sb-nn-aw
  • HCS1.1E-W0009-A-02-B-ET-EC-DA-NN-NN-FW

Frequently Asked Questions about HCS01.1E-W0009-A-02-B-ET-EC-DA-NN-NN-FW:

Q: What type of communication interface does the HCS01.1E-W0009-A-02-B-ET-EC-DA-NN-NN-FW support?

A: The HCS01.1E-W0009-A-02-B-ET-EC-DA-NN-NN-FW provides a MultiEthernet communication interface, allowing versatile network connectivity.

Q: How is the HCS01.1E-W0009-A-02-B-ET-EC-DA-NN-NN-FW cooled during operation?

A: This drive controller uses an internal air cooling method aided by an integrated blower for heat dissipation.

Q: What is the peak current capacity of the HCS01.1E-W0009-A-02-B-ET-EC-DA-NN-NN-FW?

A: The device supports a maximum peak current of 9 A.

Q: What mains voltage is required for the HCS01.1E-W0009-A-02-B-ET-EC-DA-NN-NN-FW?

A: The HCS01.1E-W0009-A-02-B-ET-EC-DA-NN-NN-FW operates with a mains voltage range of 3 x AC 110...230 V ±10%.

Q: What is the IP rating of the HCS01.1E-W0009-A-02-B-ET-EC-DA-NN-NN-FW drive controller?

A: This model has an ingress protection rating of IP20.


Internal Product Review

  • ‘‘The HCS01.1E-W0009-A-02-B-ET-EC-DA-NN-NN-FW is an HCS drive controller with a BASIC control section that feels well suited to streamlined machine builds. MultiEthernet communication and support for IndraDyn Hiperface/EnDat 2.1/2.2 feedback give the unit strong integration value in modern drive systems. Internal blower cooling and a 9 A peak current make the controller a capable choice for compact industrial applications.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo